Engineering Papers⌕ Search

Engineering topics

White, Jonathan

Publications and source records attributed to White, Jonathan.

At least 19 records

Managing Cyber Supply Chain Risk for Renewable Energy Technologies

On July 1, 2021, the U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) hosted a virtual workshop facilitated by the National Renewable Energy Laboratory (NREL). Cybersecurity supply chain experts, researchers, and leaders in government and industry came together to share information on current and future challenges in securing emerging technologies and technical architecture. From a cybersecurity perspective, we need to move from a cybersecurity approach that focuses principally on legacy asset owners to one that incorporates more emphasis on end-point device manufacturers and third-party integrators. Cybersecurity for the global digital supply chain for manufacturers of consumer end-point devices—such as smart solar inverters and smart electric vehicle (EV) chargers—will be critical to the future cyber health of the grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Aggregated PV on Subsynchronous Torsional Interaction: Preprint

This paper investigates induced oscillation (specifically subsynchronous torsional interactions) in power systems arising from photovoltaic (PV) power modulation. Time domain simulations of a modified IEEE first-benchmark system are presented and analyzed. In the IEEE benchmark system, a PV generator was added at the same bus where the synchronous generator is connected. The impact of different parameters of the PV inverters volt-volt-ampere reactive (volt-var) curve on SSTI is examined. The most severe impact found arises from the time response of the inverters reactive power change. A second-order time response with natural frequency matching the rotor speed deviation oscillation frequency and low-damping ratio quickly drives the system to an unstable region. Although it is highly unlikely that conditions necessary for distributed energy resource-induced oscillations would occur in the field, with knowledge of this vulnerability in mind, inverters' control parameters can be designed to avoid it.

aggregated↗

Roadmap for Wind Cybersecurity

The Roadmap for Wind Cybersecurity outlines the increasing challenges of cyber threats to the wind industry, its technologies, and control systems and presents a framework of activities and best practices that the wind industry can use to improve its cybersecurity.

17 WIND ENERGY↗

Impact of Aggregated PV on Subsynchronous Torsional Interaction

This paper investigates induced oscillation (specifically subsynchronous torsional interactions) in power systems arising from photovoltaic (PV) power modulation. Time domain simulations of a modified IEEE first-benchmark system are presented and analyzed. In the IEEE benchmark system, a PV generator was added at the same bus where the synchronous generator is connected. The impact of different parameters of the PV inverters’ volt-volt-ampere reactive (volt-var) curve on SSTI is examined. The most severe impact found arises from the time response of the inverter’s reactive power change. A second-order time response with natural frequency matching the rotor speed deviation oscillation frequency and low-damping ratio quickly drives the system to an unstable region. Although it is highly unlikely that conditions necessary for distributed energy resource-induced oscillations would occur in the field, with knowledge of this vulnerability in mind, inverters' control parameters can be designed to avoid it.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Intrinsic Security Design for Tomorrow’s Energy Systems

With the introduction of smart devices and rise in distributed, networked energy systems, diligent focus on cybersecurity for an evolving grid is crucial. Watch this video to learn more about what NREL is doing to mitigate threats to today’s energy infrastructure and provide a pathway to a more secure and resilient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Update to the SWiFT V27 Reference Model

A revised Sandia V27 reference model is provided for use with the wind turbine analysis code, FAST, incorporating refined parameters based on blade geometry measurements and performance data collected during the 2017 wake steering campaign at the Scaled Wind Farm Technology (SWiFT) site. The chord, twist, and airfoil section shapes were measured at five span locations on the blades of wind turbine WTGb1. The V27 AeroDyn file was updated with values equal to the measured chord and twist. The measured airfoil shapes deviated over the aft half of the chord compared to the original blade model NACA profiles. Differences in trailing edge camber were converted to an equivalent trailing edge flap effect calculated with thin airfoil theory. These mod- ified airfoil polars were updated in the V27 FAST model. The tip-speed-ratio and root bending moment were measured experimentally in the wake steering campaign at SWiFT on wind turbine WTGa1. The torque constant and collective pitch of the model were tuned so that the model output tip-speed-ratio and thrust, root bending moment matched the experiment across all wind speeds in region 2 operation with minimum error.

17 WIND ENERGY↗

Use and Testing of a Wind Turbine for the Supply of Balancing Reserves and Wide-Area Grid Stability

This report documents the use of wind turbine inertial energy for the supply of two specific electric power grid services; system balancing and real power modulation to improve grid stability. Each service is developed to require zero net energy consumption. Grid stability was accomplished by modulating the real power output of the wind turbine at a frequency and phase associated with wide-area modes. System balancing was conducted using a grid frequency signal that was high-pass filtered to ensure zero net energy. Both services used Phasor Measurement Units (PMUs) as their primary source of system data in a feedforward control (for system balancing) and feedback control (for system stability).

17 WIND ENERGY↗

Use of Wind Turbine Kinetic Energy to Supply Transmission Level Services

This paper discusses the broad use of rotational kinetic energy stored in wind turbine rotors to supply services to the electrical power grid. The grid services are discussed in terms of zero-net-energy, which do not require a reduction in power output via pitch control (spill), but neither do they preclude doing so. The services discussed include zero-net-energy regulation, transient and small signal stability, and other frequency management services. The delivery of this energy requires a trade-off between the frequency and amplitude of power modulation and is limited, in some cases, by equipment ratings and the unresearched long-term mechanical effects on the turbine. As wind displaces synchronous generation, the grid's inertial storage is being reduced, but the amount of accessible kinetic energy in a wind turbine at rated speed is approximately 6 times greater than that of a generator with only a 0.12% loss in efficiency and 75 times greater at 10% loss. The potential flexibility of the wind's kinetic storage is also high. However, the true cost of providing grid services using wind turbines, which includes a potential increase in operations and maintenance costs, have not been compared to the value of the services themselves.

17 WIND ENERGY↗

Multi-field effects in a simple extension of R {sup 2} inflation

We consider inflation in the system containing a Ricci scalar squared term and a canonical scalar field with quadratic mass term. In the Einstein frame this model takes the form of a two-field inflation model with a curved field space, and under the slow-roll approximation contains four free parameters corresponding to the masses of the two fields and their initial positions. We investigate how the inflationary dynamics and predictions for the primordial curvature perturbation depend on these four parameters. Our analysis is based on the δ N formalism, which allows us to determine predictions for the non-Gaussianity of the curvature perturbation as well as for quantities relating to its power spectrum. Depending on the choice of parameters, we find predictions that range from those of R {sup 2} inflation to those of quadratic chaotic inflation, with the non-Gaussianity of the curvature perturbation always remaining small. Using our results we are able to put constraints on the masses of the two fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Scaled Wind Farm Technology (SWiFT) Facility (Safety Assessment, Rev. 0)

This Safety Assessment (SA) documents the hazard analysis conducted for the Scaled Wind Farm Technology (SWiFT) Facility. The Sandia National Laboratories (SNL) Authorization Basis process requires Safety Assessment documents for all moderate-hazard industrial facilities. Together with the Primary Hazard Screening (PHS) Document [SNL11A00204), the SA documents the SWiFT safety basis, which is defined as the safety analysis and hazard controls that provide reasonable assurance that a DOE facility can be operated in a manner that adequately protects the workers, collocated/onsite workers, the public, and the environment. The SA specifically addresses the potential impact of hazards on the worker, collocated worker, and public.

17 WIND ENERGY↗