Engineering Papers⌕ Search

Engineering topics

White, J

Publications and source records attributed to White, J.

Culture-independent analysis of bacterial fuel contamination provides insight into the level of concordance with the standard industry practice of aerobis cultivation.

Bacterial diversity in contaminated fuels has not been systematically investigated using cultivation-independent methods. The fuel industry relies on phenotypic cultivation-based contaminant identification, which may lack accuracy and neglect difficult-to-culture taxa. By the use of industry practice aerobic cultivation, 16S rRNA gene sequencing, and strain genotyping, a collection of 152 unique contaminant isolates from 54 fuel samples was assembled, and a dominance of Pseudomonas (21%), Burkholderia (7%), and Bacillus (7%) was demonstrated. Denaturing gradient gel electrophoresis (DGGE) of 15 samples revealed Proteobacteria and Firmicutes to be the most abundant phyla. When 16S rRNA V6 gene pyrosequencing of four selected fuel samples (indicated by 'JW') was performed, Betaproteobacteria (42.8%) and Gammaproteobacteria (30.6%) formed the largest proportion of reads; the most abundant genera were Marinobacter (15.4%; JW57), Achromobacter (41.6%; JW63), Burkholderia (80.7%; JW76), and Halomonas (66.2%; JW78), all of which were also observed by DGGE. However, the Clostridia (38.5%) and Deltaproteobacteria (11.1%) identified by pyrosequencing in sample JW57 were not observed by DGGE or aerobic culture. Genotyping revealed three instances where identical strains were found: (i) a Pseudomonas sp. strain recovered from 2 different diesel fuel tanks at a single industrial site; (ii) a Mangroveibacter sp. strain isolated from 3 biodiesel tanks at a single refinery site; and (iii) a Burkholderia vietnamiensis strain present in two unrelated automotive diesel samples. Overall, aerobic cultivation of fuel contaminants recovered isolates broadly representative of the phyla and classes present but lacked accuracy by overrepresenting members of certain groups such as Pseudomonas.

33 ADVANCED PROPULSION SYSTEMS↗

The dipole corrector magnets for the RHIC fast global orbit feedback system

The recently completed RHIC fast global orbit feedback system uses 24 small 'window-frame' horizontal dipole correctors. Space limitations dictated a very compact design. The magnetic design and modelling of these laminated yoke magnets is described as well as the mechanical implementation, coil winding, vacuum impregnation, etc. Test procedures to determine the field quality and frequency response are described. The results of these measurements are presented and discussed. A small fringe field from each magnet, overlapping the opposite RHIC ring, is compensated by a correction winding placed on the opposite ring's magnet and connected in series with the main winding of the first one. Results from measurements of this compensation scheme are shown and discussed.

43 PARTICLE ACCELERATORS↗

RHIC 10 Hz global orbit feedback system

Vibrations of the cryogenic triplet magnets at the Relativistic Heavy Ion Collider (RHIC) are suspected to be causing the horizontal beam perturbations observed at frequencies around 10 Hz. Several solutions to counteract the effect have been considered in the past, including a local beam feedback system at each of the two experimental areas, reinforcing the magnet base support assembly, and a mechanical servo feedback system. However, the local feedback system was insufficient because perturbation amplitudes outside the experimental areas were still problematic, and the mechanical solutions are very expensive. A global 10 Hz orbit feedback system consisting of 36 beam position monitors (BPMs) and 12 small dedicated dipole corrector magnets in each of the two 3.8 km circumference counter-rotating rings has been developed and commissioned in February 2011. A description of the system architecture and results with beam will be discussed.

43 PARTICLE ACCELERATORS↗

Plasma diagnostics for investigating extreme ultraviolet light sources

Plasma temperature and density diagnostics are crucial for lithographic applications of extreme ultraviolet light sources. One widely used technique employs line intensity ratios of successively charged ion states to determine the ion temperature (T{sub ionz}). This work comprises a detailed ''stress-test'' of the applied technique, where space and time resolved emission in laser-produced plasmas were studied, using a Nd:yttrium aluminum garnet laser pulse incident on an aluminum target in the 26.5-32.5 nm range. Detailed hydrodynamic simulations also investigate the dependency of ion temperature on electron density and the charge states for various line combinations (Al VI/V, Al VII/VI, Al VIII/VII, Al IX/VIII, and Al X/IX).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simplified one-dimensional calculation of 13.5 nm emission in a tin plasma including radiation transport

Many next generation lithography schemes for the semiconductor industry are based on a 13.5 nm tin plasma light source, where hundreds of thousands of 4d-4f, 4p-4d, and 4d-5p transitions from Sn{sup 5+}-Sn{sup 13+} ions overlap to form an unresolved transition array. To aid computation, transition arrays are treated statistically, and Hartree-Fock results are used to calculate radiation transport in the optically thick regime with a one-dimensional Lagrangian plasma hydrodynamics code. Time-dependent spectra and conversion efficiencies of 2% in-band 13.5 nm emission to laser energy are predicted for a Nd:YAG (yttrium aluminum garnet) laser incident on a pure tin slab target as a function of laser power density and pulse duration at normal incidence. Calculated results showed a maximum conversion efficiency of 2.3% for a 10 ns pulse duration at 8.0x10{sup 10} W/cm{sup 2} and are compared to experimental data where available. Evidence for the need to include lateral expansion is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of the LUX dark matter search

The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within various timeframes ranging from 1 year to 5 years or more.

Fiorucci, S↗