Recalculating Dissolver Curves for Critical Parameters for Nuclear Criticality Safety
The dissolver paradox is a phenomenon in criticality safety whereby a high density fissile material is being dissolved in a low fissile density solution and is subcritical before and after dissolution. However, as the metal is being dissolved, there may be an intermediate concentration that leads to a critical state. CCG-184 is a Y-12 report written in 1980 that provided critical parameter data for two separate dissolver paradox scenarios: solid metal spheres and hollow metal spheres with internal moderation effects. The sphere and shell are both surrounded by solution, however the shell contains solution of the same concentration within itself. In 1980, there are limitations to the computational methods to determine critical parameters. These are due to the lower number of energy groups utilized (16-group) at the time, smaller number of established cross-sectional data, as well as a larger uncertainty within the resonance region of neutron energies. With these constraints in mind, these critical parameters are recalculated with newer cross-sectional data, a newer Monte Carlo code: SCALE 6.1.3 using KENO V.a, and a larger number of energy bins.