Engineering PapersSearch

Engineering topics

Wen, L. C.

Publications and source records attributed to Wen, L. C..

The Pathfinder Microrover

An exciting scientific component of the Pathfinder mission is the rover, which will act as a mini-field geologist by providing us with access to samples for chemical analyses and close-up images of the Martian surface, performing active experiments to modify the surface and study the results, and exploring the landing site area.

Mars Mars Pathfinder rover microrover imager for p

Solder Creep-Fatigue Interactions with Flexible Leaded Part

In most electronic packaging applications it is not a single high stress event that breaks a component solder joint; rather it is repeated or prolonged load applications that result in fatigue or creep failure of the solder. The principal strain in solder joints is caused by differential expansion between the part and its mounting environment due to hanges in temperature (thermal cycles) and/or due to temperature gradients between the part and the board.

creep effects

Solder creep-fatigue interactions with flexible leaded parts

With flexible leaded parts, the solder-joint failure process involves a complex interplay of creep and fatigue mechanisms. To better understand the role of creep in typical multi-hour cyclic loading conditions, a specialized non-linear finite-element creep simulation computer program has been formulated. The numerical algorithm includes the complete part-lead-solder-PWB system, accounting for strain-rate dependence of creep on applied stress and temperature, and the role of the part-lead dimensions and flexibility that determine the total creep deflection (solder strain range) during stress relaxation. The computer program has been used to explore the effects of various solder creep-fatigue parameters such as lead height and stiffness, thermal-cycle test profile, and part/board differential thermal expansion properties. One of the most interesting findings is the strong presence of unidirectional creep-ratcheting that occurs during thermal cycling due to temperature dominated strain-rate effects. To corroborate the solder fatigue model predictions, a number of carefully controlled thermal-cycle tests have been conducted using special bimetallic test boards.

Ross, R. G., Jr.

Leakage-current properties of encapsulants

A theoretical modeling of leakage current in ethylene vinyl acetate (EVA) and polyvinyl butyral (PVB) modules is being developed and is described. The modeling effort derives mathematical relationships for the bulk and surface conductivites of EVA and PVB, the surface conductivities of glass and polymeric films, and the EVA and PVB pottants, all as functions of environmental parameters. Results from the modeling indicate that for glass/EVA, the glass surface controls the interfacial conductivity, although EVA bulk conductivity controls total leakage current. For PVB/glass, the interface conductivity controls leakage currents for relative humidity (RH) less than 40 to 50%, but PVB bulk conductivity controls leakage current above 50% RH.

Wen, L. C.

Preliminary study: Moisture-polymer interaction. Stuby objectives

The problems associated with mathematically modeling water-module interaction phenomena, including sorption and desorption, diffusion, and permeation are discussed. With reliable analytical models, an extensive materials data base, and solar radiation surface meteorological observations (SOLMET) weather data, predicting module lifetimes in realistic environments can become a practical reality. The status of the present techniques of simulating the various transport mechanisms was reported. The Dent model (a modified Brunauer-Emmet-Teller) approach represented polyvinyl butyral (PVB) sorption data. A 100-layer material model and Fick's diffusion model gave diffusivity values exhibiting adequate agreement with those measured for PVB. Diffusivity of PVB is concentration dependent, decreasing as the water content in PVB increases. The temperature dependence of diffusion in PVB is well modeled by the Arrhenius rate equation. Equilibrium conductivity and leakage current data are well represented by Hearle's model for bulk ionic conductivity. A nodal network analysis using the Systems Improved Numerical Differencing Analyzer (SINDA) Thermal Analyzer gave reasonable correlation with measurable data. It is concluded that realistic lifetime predictions seem to be feasible.

Wen, L. C.

Evaluating Solar Collectors

Survey discusses several methods for assessing performance of solar-concentrator designs to determine whether given design suitable for given high-temperature solar powered generator system.

Wen, L. C.

Cost Effectiveness of Hybrid Solar Powerplants

Report discusses cost effectiveness of high-temperature thermal storage system for representative parabolic dish solar powerplant. Economic viability of thermal storage system assesses; cost and performance projections made; cost of electricity generated by solar power plant also calculated.

Wen, L. C.

Solar receiver performance of point focusing collector system

The solar receiver performance of cavity receivers and external receivers used in dispersed solar power systems was evaluated for the temperature range 300-1300 C. Several parameters of receiver and concentrator are examined. It was found that cavity receivers are generally more efficient than external receivers, especially at high temperatures which require a large heat transfer area. The effects of variation in the ratio of receiver area to aperture area are considered.

Wu, Y. C.