Engineering PapersSearch

Engineering topics

Welter, Gary

Publications and source records attributed to Welter, Gary.

ACS Without an Attitude

The book (ACS without an Attitude) is an introduction to spacecraft attitude control systems. It is based on a series of lectures that Dr. Hallock presented in the early 2000s to members of the GSFC flight software branch, the target audience being flight software engineers (developers and testers), fairly new to the field that desire an introductory understanding of spacecraft attitude determination and control.

Attitude Estimation

Precision Pointing for the Wide-Field Infrared Survey Telescope (WFIRST)

The Wide-Field Infrared Survey Telescope (WFIRST) mission, scheduled for a mid-2020's launch, is currently in its definition phase. The mission is designed to investigate essential questions in the areas of dark energy, exoplanets, and infrared astrophysics. WFIRST will use a 2.4-meter primary telescope (same size as the Hubble Space Telescope's primary mirror) and two instruments: the Wide Field Instrument (WFI) and the Coronagraph Instrument (CGI). In order to ad-dress the critical science requirements, the WFIRST mission will conduct large-scale surveys of the infrared sky, requiring both agility and precision pointing (11.6 milli-arcsec stability, 14 milli-arcsec jitter). This paper describes some of the challenges this mission profile presents to the GNC subsystem, and some of the design elements chosen to accommodate those challenges. The high-galactic-latitude survey is characterized by 3-minute observations separated by slews ranging from 0.025 deg to 0.8 deg. The need for observation efficiency drives the slew and settle process to be as rapid as possible. A description of the shaped slew profile chosen to minimize excitation of structural oscillation, and the handoff from star tracker-gyro control to fine guidance sensor control is detailed. Also presented is the fine guidance sensor (FGS), which is integral with the primary instrument (WFI). The FGS is capable of tracking up to 18 guide stars, enabling robust FGS acquisition and precision pointing. To avoid excitation of observatory structural jitter, reaction wheel speeds are operationally maintained within set limits. In addition, the wheel balance law is designed to maintain 1-Hz separation between the wheel speeds to avoid reinforcing jitter excitation at any particular frequency. The wheel balance law and operational implications are described. Finally, the candidate GNC hardware suite needed to meet the requirements of the mission is presented.

Stoneking, Eric

Precision Pointing for the Wide-Field Infrared Survey Telescope(WFIRST)

The Wide-Field Infrared Survey Telescope (WFIRST) mission, scheduled for a mid-2020's launch, is currently in its definition phase. The mission is designed to investigate essential questions in the areas of dark energy, exoplanets, and infrared astrophysics. WFIRST will use a 2.4-meter primary telescope (same size as the Hubble Space Telescope's primary mirror) and two instruments: the Wide Field Instrument (WFI) and the Coronagraph Instrument (CGI). In order to address the critical science requirements, the WFIRST mission will conduct large-scale surveys of the infrared sky, requiring both agility and precision pointing (11.6 milli-arcsec stability, 14 milli-arcsec jitter). This paper describes some of the challenges this mission profile presents to the Guidance, Navigation, and Control (GNC) subsystem, and some of the design elements chosen to accommodate those challenges. The high-galactic-latitude survey is characterized by 3-minute observations separated by slews ranging from 0.025 deg to 0.8 deg. The need for observation efficiency drives the slew and settle process to be as rapid as possible. A description of the shaped slew profile chosen to minimize excitation of structural oscillation, and the handoff from star tracker-gyro control to fine guidance sensor control is detailed. Also presented is the fine guidance sensor (FGS), which is integral with the primary instrument (WFI). The FGS is capable of tracking up to 18 guide stars, enabling robust FGS acquisition and precision pointing. To avoid excitation of observatory structural jitter, reaction wheel speeds are operationally maintained within set limits. In addition, the wheel balance law is designed to maintain 1-Hz separation between the wheel speeds to avoid reinforcing jitter excitation at any particular frequency. The wheel balance law and operational implications are described. Finally, the candidate GNC hardware suite needed to meet the requirements of the mission is presented.

Stoneking, Eric T.

Global Precipitation Measurement Mission Launch and Commissioning

During launch and early operation of the Global Precipitation Measurement (GPM) Mission, the Guidance, Navigation and Control (GNC) analysis team encountered four main on orbit anomalies. These include: (1) unexpected shock from Solar Array deployment, (2) momentum buildup from the Magnetic Torquer Bars (MTBs) phasing errors, (3) transition into Safehold due to albedo-induced Course Sun Sensor (CSS) anomaly, and (4) a flight software error that could cause a Safehold transition due to a Star Tracker occultation. This paper will discuss ways GNC engineers identified and tracked down the root causes. Flight data and GNC on board models will be shown to illustrate how each of these anomalies were investigated and mitigated before causing any harm to the spacecraft. On May 29, 2014, GPM was handed over to the Mission Flight Operations Team after a successful commissioning period. Currently, GPM is operating nominally on orbit, collecting meaningful scientific data that will significantly improve our understanding of the Earth's climate and water cycle.

Guidance Navigation and Control

Global Precipitation Measurement Mission Launch and Commissioning

During launch and early operation of the Global Precipitation Measurement (GPM) Mission, the Guidance, Navigation, and Control (GN&C) analysis team encountered four main on-orbit anomalies. These include: (1) unexpected shock from Solar Array deployment, (2) momentum buildup from the Magnetic Torquer Bars (MTBs) phasing errors, (3) transition into Safehold due to albedo induced Course Sun Sensor (CSS) anomaly, and (4) a flight software error that could cause a Safehold transition due to a Star Tracker occultation. This paper will discuss ways GN&C engineers identified the anomalies and tracked down the root causes. Flight data and GN&C on-board models will be shown to illustrate how each of these anomalies were investigated and mitigated before causing any harm to the spacecraft. On May 29, 2014, GPM was handed over to the Mission Flight Operations Team after a successful commissioning period. Currently, GPM is operating nominally on orbit, collecting meaningful scientific data that will significantly improve our understanding of the Earth's climate and water cycle.

Guidance Navigation and Control

Towards Automating Spacecraft Attitude Sensor Calibration

With a view towards reducing cost and complexity for spacecraft early mission support at the NASA Goddard Space Flight Center (GSFC), efforts are being made to automate the attitude sensor calibration process. This paper addresses one of the major components needed by such a system. The beneficiaries of an improved calibration process are missions that demand moderate to high precision attitude knowledge or that need to perform accurate attitude slews. Improved slew accuracy reduces the time needed for re-acquisition of fine-pointing after each attitude maneuver, Rapid target acquisition can be very important for astronomical targeting or for off-nadir surface feature targeting by Earth-oriented spacecraft. The normal sequence of on-orbit calibration starts with alignment calibration of the star trackers and possibly the Sun sensor. Their relative alignment needs to be determined using a sufficiently large data set so their fields of view are adequately sampled. Next, the inertial reference unit (IRU) is calibrated for corrections to its alignment and scale factors. The IRU biases are estimated continuously by the onboard attitude control system, but the IRU alignment and scale factors are usually determined on the ground using a batch-processing method on a data set that includes several slews sufficient to give full observability of all the IRU calibration parameters. Finally, magnetometer biases, alignment, and its coupling to the magnetic torquers are determined in order io improve momentum management and occasionally for use in the attitude determination system. The detailed approach used for automating calibrations will depend on whether the automated system resides on the ground or on the spacecraft with an ultimate goal of autonomous calibration. Current efforts focus on a ground-based system driving subsystems that could run either on the ground or onboard. The distinction is that onboard calibration should process the data sequentially rather than in a single large batch since onboard computer data storage is limited. Very good batch- processing calibration utilities have been developed and used extensively at NASA/GSFC for mission support but no sequential calibration utilities are available. To meet this need, this paper presents the mathematical description of a sequential IRU calibration system. The system has been tested using flight data from the Rossi X-ray Timing Explorer (RXTE) during a series of attitude slews. The paper also discusses the current state of the overall automated system and describes plans for adding sequential alignment calibration and other additions that will reduce the amount of analyst time and input.

Sedlak, Joseph