Engineering Papers⌕ Search

Engineering topics

Wei, Jie

Publications and source records attributed to Wei, Jie.

The High Rigidity Spectrometer at the FRIB: Magnet Development Status

This paper presents the 2025 progress of the High Rigidity Spectrometer (HRS) project at the Facility for Rare Isotope Beams (FRIB). We report on the construction and testing of the first-article HRS-High Transmission BeamLine (HTBL) magnets. An HTBL dipole magnet has successfully completed cold testing, achieving full magnetic performance without quenching, and is now ready for field mapping at FRIBs offline test bench. HTBL quadrupole triplet coils have been fabricated and tested, with all coils reaching their design currents, some following initial training quenches. Furthermore, the preliminary design of the large-scale, large-aperture SPectrometer Section (SPS) magnets has progressed to determine the baseline of the downstream HRS-SPS subproject in 2025. This includes the introduction of novel magnet designs, such as the sweeper dipole magnet, the sector dipole magnet, and iron-free coil-dominated quadrupole magnets, representing a significant scale breakthrough and a first for FRIB.

Choi, Yoonhyuck↗

FRIB Beam Power Ramp-up: Status and Plans

After project completion on scope, on cost, and ahead of schedule, the Facility for Rare Isotope Beams began operations for scientific users in May of 2022. The ramp-up to a beam power of 400 kW is planned over a six-year period; 1 kW was delivered for initial user runs from in 2022, and 5 kW was delivered as of February 2023. Test runs with 10 kW 36Ar and 48Ca beams were conducted in July 2023. Upgrade plans include doubling the primary-beam energy to 400 MeV/nucleon for enhanced discovery potential (¿FRIB 400¿). This talk reports on the strategic plans towards high power operations emphasizing challenges and resolutions in beam-interception devices and targetry systems, radiation protection and controls, and legacy system renovation and integration.

43 PARTICLE ACCELERATORS↗

FRIB Transition to User Operations, Power Ramp Up, and Upgrade Perspectives

After project completion on scope, on cost, and ahead of schedule, the Facility for Rare Isotope Beams began operations for scientific users in May of 2022. During the first 12 months of user operations, the FRIB accelerator complex delivered 5250 beam hours, including 1528 hours to nine science experiments conducted with primary beams of 36Ar, 48Ca, 70Zn, 82Se, 124Xe, and 198Pt at beam energies >200 MeV/u; 2724 hours for beam developments, studies, and tuning; and 998 hours to industrial users and non-scientific programs using the FRIB Single Event Effect (FSEE) beam line. The ramp-up to a beam power of 400 kW is planned over a six-year period; 1 kW was delivered for initial user runs from in 2022, and 5 kW was delivered as of February 2023. Upgrade plans include doubling the primary-beam energy to 400 MeV/nucleon for enhanced discovery potential (¿FRIB 400¿). This talk reports on FRIB status and progress since SRF2021, emphasizing lessons learned during the transition from beam commissioning to machine operations, challenges and resolutions for the power ramp-up, progress with accelerator improvements, and R&D for the energy upgrade.

43 PARTICLE ACCELERATORS↗

Experimental Demonstration of the Thin-Film Liquid-Metal Jet as a Charge Stripper

For high-power heavy ion accelerators, the development of a suitable charge stripper, which can handle intense beams, is essential. This Letter describes the first experimental demonstration of a heavy ion liquid lithium charge stripper. A 10–20 μm thick liquid lithium jet flowing at >50 m/s was formed and confirmed stable when bombarded by various heavy ion beams, while increasing the charge state of the incoming beams to the desired charge state range. Finally, this demonstration proved the existing power limitation with the conventional strippers can be overcome by the liquid-metal stripper, opening completely new possibilities in high-power accelerator development.

43 PARTICLE ACCELERATORS↗

Design of β=0.65, 5 Cells, 644 MHz Elliptical Cavity for FRIB Upgrade

The superconducting (SC) linac of the Facility for Rare Isotope Beams (FRIB) under construction will deliver 200 MeV/u, 400 kW beam to the target for producing rare isotopes at Michigan State of University (MSU). For further beam energy upgrade, we have designed the β = 0.65, 5 cells, 644 MHz elliptical cavity. The beam energy can be upgraded to 400 MeV/u by installing 11 cryomodules to the available space in the FRIB tunnel.

43 PARTICLE ACCELERATORS↗

Influence of the secondary phase on micro galvanic corrosion of low carbon bainitic steel in NaCl solution

Highlights: • Micro galvanic couple forms between steel matrix and secondary phase for LCB steel. • Micro galvanic couple causes non-uniform corrosion on micro area surface of steel. • The ω secondary phase acts as the micro anode in lath bainitic steel. • The M secondary phase acts as the micro cathode in granular bainitic steel. • Galvanic accelerated corrosion is obvious initially and weakened for long term. - Abstract: The corrosion behavior of lath bainitic and granular bainitic steels in 0.01 mol/L NaCl solution was studied by SEM and TEM observation, electrochemical monitoring and weight loss test. The results indicate that the micro galvanic couple forms between the steel matrix and the secondary phase, which causes non-uniform micro corrosion on surfaces of two steels. In lath bainitic steel, the secondary phase ω acts as the micro anode. While in granular bainitic steel, the secondary phase M acts as the micro cathode. Moreover, the corrosion acceleration caused by micro galvanic couple is obvious in the initial immersion stage, and then it becomes weak during the long term corrosion.

36 MATERIALS SCIENCE↗

FRIB Project Status and Beam Instrumentation Challenges

With an average beam power two orders of magnitude higher than operating heavy-ion facilities, the Facility for Rare Isotope Beams (FRIB) stands at the power frontier of the accelerator family. This report summarizes the status of design, technology development, construction, commissioning, as well as path to operations and upgrades. We also highlight beam instrumentation challenges including machine protection of high-power heavy-ion beams and complications of multi-charge-state and multi-ion-species accelerations.

43 PARTICLE ACCELERATORS↗

Novel Super-Resolution Approach to Time-Resolved Volumetric 4-Dimensional Magnetic Resonance Imaging With High Spatiotemporal Resolution for Multi-Breathing Cycle Motion Assessment

Purpose: To develop and evaluate a super-resolution approach to reconstruct time-resolved 4-dimensional magnetic resonance imaging (TR-4DMRI) with a high spatiotemporal resolution for multi-breathing cycle motion assessment. Methods and Materials: A super-resolution approach was developed to combine fast 3-dimensional (3D) cine MRI with low resolution during free breathing (FB) and high-resolution 3D static MRI during breath hold (BH) using deformable image registration. A T1-weighted, turbo field echo sequence, coronal 3D cine acquisition, partial Fourier approximation, and SENSitivity Encoding parallel acceleration were used. The same MRI pulse sequence, field of view, and acceleration techniques were applied in both FB and BH acquisitions; the intensity-based Demons deformable image registration method was used. Under an institutional review board–approved protocol, 7 volunteers were studied with 3D cine FB scan (voxel size: 5 × 5 × 5 mm{sup 3}) at 2 Hz for 40 seconds and a 3D static BH scan (2 × 2 × 2 mm{sup 3}). To examine the image fidelity of 3D cine and super-resolution TR-4DMRI, a mobile gel phantom with multi-internal targets was scanned at 3 speeds and compared with the 3D static image. Image similarity among 3D cine, 4DMRI, and 3D static was evaluated visually using difference image and quantitatively using voxel intensity correlation and Dice index (phantom only). Multi-breathing-cycle waveforms were extracted and compared in both phantom and volunteer images using the 3D cine as the references. Results: Mild imaging artifacts were found in the 3D cine and TR-4DMRI of the mobile gel phantom with a Dice index of >0.95. Among 7 volunteers, the super-resolution TR-4DMRI yielded high voxel-intensity correlation (0.92 ± 0.05) and low voxel-intensity difference (<0.05). The detected motion differences between TR-4DMRI and 3D cine were −0.2 ± 0.5 mm (phantom) and −0.2 ± 1.9 mm (diaphragms). Conclusion: Super-resolution TR-4DMRI has been reconstructed with adequate temporal (2 Hz) and spatial (2 × 2 × 2 mm{sup 3}) resolutions. Further TR-4DMRI characterization and improvement are necessary before clinical applications. Multi-breathing cycles can be examined, providing patient-specific breathing irregularities and motion statistics for future 4D radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Respiratory Motion Perturbation Model Adaptable to Patient Breathing Irregularities

Purpose: To develop a physical, adaptive motion perturbation model to predict tumor motion using feedback from dynamic measurement of breathing conditions to compensate for breathing irregularities. Methods and Materials: A novel respiratory motion perturbation (RMP) model was developed to predict tumor motion variations caused by breathing irregularities. This model contained 2 terms: the initial tumor motion trajectory, measured from 4-dimensional computed tomography (4DCT) images, and motion perturbation, calculated from breathing variations in tidal volume (TV) and breathing pattern (BP). The motion perturbation was derived from the patient-specific anatomy, tumor-specific location, and time-dependent breathing variations. Ten patients were studied, and 2 amplitude-binned 4DCT images for each patient were acquired within 2 weeks. The motion trajectories of 40 corresponding bifurcation points in both 4DCT images of each patient were obtained using deformable image registration. An in-house 4D data processing toolbox was developed to calculate the TV and BP as functions of the breathing phase. The motion was predicted from the simulation 4DCT scan to the treatment 4DCT scan, and vice versa, resulting in 800 predictions. For comparison, noncorrected motion differences and the predictions from a published 5-dimensional model were used. Results: The average motion range in the superoinferior direction was 9.4 ± 4.4 mm, the average ΔTV ranged from 10 to 248 mm{sup 3} (−26% to 61%), and the ΔBP ranged from 0 to 0.2 (−71% to 333%) between the 2 4DCT scans. The mean noncorrected motion difference was 2.0 ± 2.8 mm between 2 4DCT motion trajectories. After applying the RMP model, the mean motion difference was reduced significantly to 1.2 ± 1.8 mm (P=.0018), a 40% improvement, similar to the 1.2 ± 1.8 mm (P=.72) predicted with the 5-dimensional model. Conclusions: A novel physical RMP model was developed with an average accuracy of 1.2 ± 1.8 mm for interfraction motion prediction, similar to that of a published lung motion model. This physical RMP was analytically derived and is able to adapt to breathing irregularities. Further improvement of this RMP model is under investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel spirometry based on optical surface imaging

Purpose: To evaluate the feasibility of using optical surface imaging (OSI) to measure the dynamic tidal volume (TV) of the human torso during free breathing. Methods: We performed experiments to measure volume or volume change in geometric and deformable phantoms as well as human subjects using OSI. To assess the accuracy of OSI in volume determination, we performed experiments using five geometric phantoms and two deformable body phantoms and compared the values with those derived from geometric calculations and computed tomography (CT) measurements, respectively. To apply this technique to human subjects, an institutional review board protocol was established and three healthy volunteers were studied. In the human experiment, a high-speed image capture mode of OSI was applied to acquire torso images at 4–5 frames per second, which was synchronized with conventional spirometric measurements at 5 Hz. An in-house MATLAB program was developed to interactively define the volume of interest (VOI), separate the thorax and abdomen, and automatically calculate the thoracic and abdominal volumes within the VOIs. The torso volume change (TV C = ΔV{sub torso} = ΔV{sub thorax} + ΔV{sub abdomen}) was automatically calculated using full-exhalation phase as the reference. The volumetric breathing pattern (BP{sub v} = ΔV{sub thorax}/ΔV{sub torso}) quantifying thoracic and abdominal volume variations was also calculated. Under quiet breathing, TVC should equal the tidal volume measured concurrently by a spirometer with a conversion factor (1.08) accounting for internal and external differences of temperature and moisture. Another MATLAB program was implemented to control the conventional spirometer that was used as the standard. Results: The volumes measured from the OSI imaging of geometric phantoms agreed with the calculated volumes with a discrepancy of 0.0% ± 1.6% (range −1.9% to 2.5%). In measurements from the deformable torso/thorax phantoms, the volume differences measured using OSI imaging and CT imaging were 1.2% ± 2.1% (range −0.5% to 3.6%), with a linear regression fitting (slope = 1.02 and R{sup 2} = 0.999). In volunteers, the relative error in OSI tidal volume measurement was −2.2% ± 4.9% (range −9.2% to 4.8%) and a correlation of r = 0.98 was found with spirometric measurement. The breathing pattern values of the three volunteers were substantially different from each other (BP{sub v} = 0.15, 0.45, and 0.32). Conclusions: This study demonstrates the feasibility of using OSI to measure breathing tidal volumes and breathing patterns with adequate accuracy. This is the first time that dynamic breathing tidal volume as well as breathing patterns is measured using optical surface imaging. The OSI-observed movement of the entire torso could serve as a new respiratory surrogate in the treatment room during radiation therapy.

60 APPLIED LIFE SCIENCES↗

Influence of epitaxial strain on elastocaloric effect in ferroelectric thin films

We report the influence of epitaxial strain u{sub m} on the elastocaloric properties of BaTiO{sub 3} thin films. Using thermodynamic calculations, we show that there exists a critical compressive stress σ{sub 3c} at which the elastocaloric effect is maximized for any compressive misfit strain we investigate. Moreover, it is found that |σ{sub 3c}| decreases significantly with decreasing |u{sub m}|, which is accompanied by a reduction of the elastocaloric response. Interestingly, a several fold enhancement in the electrocaloric effect can be achieved for stress in proximity of σ{sub 3c}. The elastocaloric effect predicted here may find potential cooling applications by combining the stress-mediated electrocaloric effect or designing hybrid elastocaloric/electrocaloric devices in the future.

36 MATERIALS SCIENCE↗

Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity

Purpose: Motion artifacts are common in patient four-dimensional computed tomography (4DCT) images, leading to an ill-defined tumor volume with large variations for radiotherapy treatment and a poor foundation with low imaging fidelity for studying respiratory motion. The authors developed a method to estimate 4DCT image quality by establishing a correlation between the severity of motion artifacts in 4DCT images and the periodicity of the corresponding 1D respiratory waveform (1DRW) used for phase binning in 4DCT reconstruction. Methods: Discrete Fourier transformation (DFT) was applied to analyze 1DRW periodicity. The breathing periodicity index (BPI) was defined as the sum of the largest five Fourier coefficients, ranging from 0 to 1. Distortional motion artifacts (excluding blurring) of cine-scan 4DCT at the junctions of adjacent couch positions around the diaphragm were classified in three categories: incomplete, overlapping, and duplicate anatomies. To quantify these artifacts, discontinuity of the diaphragm at the junctions was measured in distance and averaged along six directions in three orthogonal views. Artifacts per junction (APJ) across the entire diaphragm were calculated in each breathing phase and phase-averaged APJ{sup ¯}, defined as motion-artifact severity (MAS), was obtained for each patient. To make MAS independent of patient-specific motion amplitude, two new MAS quantities were defined: MAS{sup D} is normalized to the maximum diaphragmatic displacement and MAS{sup V} is normalized to the mean diaphragmatic velocity (the breathing period was obtained from DFT analysis of 1DRW). Twenty-six patients’ free-breathing 4DCT images and corresponding 1DRW data were studied. Results: Higher APJ values were found around midventilation and full inhalation while the lowest APJ values were around full exhalation. The distribution of MAS is close to Poisson distribution with a mean of 2.2 mm. The BPI among the 26 patients was calculated with a value ranging from 0.25 to 0.93. The DFT calculation was within 3 s per 1DRW. Correlations were found between 1DRW periodicity and 4DCT artifact severity: −0.71 for MAS{sup D} and −0.73 for MAS{sup V}. A BPI greater than 0.85 in a 1DRW suggests minimal motion artifacts in the corresponding 4DCT images. Conclusions: The breathing periodicity index and motion-artifact severity index are introduced to assess the relationship between 1DRW and 4DCT. A correlation between 1DRW periodicity and 4DCT artifact severity has been established. The 1DRW periodicity provides a rapid means to estimate 4DCT image quality. The rapid 1DRW analysis and the correlative relationship can be applied prospectively to identify irregular breathers as candidates for breath coaching prior to 4DCT scan and retrospectively to select high-quality 4DCT images for clinical motion-management research.

60 APPLIED LIFE SCIENCES↗

Giant room-temperature barocaloric effect and pressure-mediated electrocaloric effect in BaTiO{sub 3} single crystal

Barocaloric effect in BaTiO{sub 3} single crystal is studied by a thermodynamic phenomenological model. It is demonstrated that a giant barocaloric effect can be achieved near room temperature with an adiabatic temperature change of more than 3 K and a temperature span about 50 K. As expected, the electrocaloric peak can be shifted towards room temperature by pressure. However, a slight reduction of the electrocaloric peak is found in contrast to relaxor ferroelectrics and LiNbO{sub 3}. We believe that our findings could open a potential route by combining the barocaloric effect and pressure-mediated electrocaloric effect in BaTiO{sub 3} single crystal for cooling devices.

36 MATERIALS SCIENCE↗

Low-temperature hydrothermal synthesis of BiFeO{sub 3} microcrystals and their visible-light photocatalytic activity

Highlights: ► Urea-assisted hydrothermal synthesis of pure BiFeO{sub 3} at 120 °C was reported. ► Possible formation mechanism of pure phase BiFeO{sub 3} at low temperature was illuminated. ► BiFeO{sub 3} microcrystals exhibited efficient visible-light photocatalytic activity. -- Abstract: Pure BiFeO{sub 3} (BFO) microcrystals were synthesized at the temperature as low as 120 °C via a urea-assisted hydrothermal process. The crystal structure, morphology and photocatalytic property of BFO microcrystals were investigated. The analysis reveals that the hydrolysis of urea in the hydrothermal process plays a key role in the synthesis of pure phase BFO microcrystals. FE-SEM and TEM results show that these BFO microcrystals present a nearly spherical microstructure, and specially exhibit superstructures consisting of large amounts of small particles with the size of 100–150 nm by further observation. Moreover, these BFO microcrystals exhibit efficient photocatalytic activity under visible-light irradiation, suggesting their promising applications as photocatalysts and related fields.

36 MATERIALS SCIENCE↗