Properties of nearly perfect crystals at very low temperatures

Data shows that the frequency stability of 5 MHz AT-cut quartz crystal oscillators is improved by lowering the temperature to 4.3 K. The resultant level of stability is apparently not, at this point, sufficient for a clock accurate to 1 part in 10(exp 17). However, many improvements are possible in the scheme presented here. These would involve better temperature regulation, better crystal mounting and vibration isolation, and lower temperatures. Below the lambda-transition at 2.17 K the residual bubbling of the bath would be eliminated. Thus, the prospect of a successful clock built on this scheme is not ruled out.

Weber, J.

Removal of Residual Chromium from Aluminum Oxide by Containerless Liquid-phase Processing

Berneuil sapphire was purified of Cr 3+ by containerless melting and processing at ca. 2550 K in high purity argon, dry air and pure oxygen. Recovered material was examined by laser induced fluorescence and Raman spectroscopy. The Cr 3+ fluorescence intensity decreased in processed specimens at rates proportional to the chromium concentration and p(O 2 ) 0.21 . The initial chromium concentration was ca. 5 ppm and decreased by factors of ca. 50, 3000, and 2x10 5 after processing for 300 seconds in argon, air and oxygen, respectively. Evidence is presented that the Cr 3+ was removed predominantly as CrO 2 (g) and not by conversion to other oxidation states of chromium in the condensed phase. A comparison of the Raman peak shifts for as-received and processed samples indicates that considerable stress was retained during containerless solidification of the highly undercooled melts.

sapphire

Properties of large nearly perfect crystals at very low temperatures

A liquid helium cryostat of a size and construction unavailable commercially, was built for use in measuring the Q of several materials at milli-Kelvin temperatures. The design and testing of the cryostat is described as well as the design of the experiment vacuum chamber and adaptor for the dilution refrigerator insert. Theory, design, and testing are also discussed for the magnetic coils built to levitate the materials so as to isolate them and increase the measured Q. A four point suspension with capacitor end plates as the transducer was used to obtain preliminary Q measurements of 6061 aluminum alloy and single crystal silicon. Results are tabulated.

Davis, W.

Solid state crystal physics at very low temperatures

The mechanical dissipation (Q) and resonant frequency of a 15 kg silicon crystal were measured at cryogenic temperatures. In the experiment described, temperature control was incorporated to reduce the time derivative of the temperature. The results of the Q measurements with and without this temperature control are quite different. Measurements of the resonant frequency of the fundamental longitudinal mode of the silicon crystal from 6 to 300 Kelvin are presented and discussed with respect to temperature, df/dT. It is observed that frequency increases as temperature decreases down to about 16 Kelvin, i.e. dt/dT is negative. However, below this temperature the frequency decreases as temperature decreases, i.e. dt/dT is positive. It is suggested that this behavior is related to the coefficient of thermal contraction of silicon, which changes sign at 18 Kelvin. Continuation of these experiments to 20 mK is discussed.

Davis, W.

Solid state crystal physics at very low temperatures

The properties of nearly perfect crystals was studied at cryogenic temperatures. A large Helium 3 and Helium 4 dilution refrigerator has been assembled, and is described. A cryostat suitable for cooling a 35 liter volume to .020 Kelvin was designed and constructed, together with instrumentation to observe the properties of nearly perfect crystals.

Davis, W.

Lunar surface gravimeter experiment

The lunar surface gravimeter used the moon as an instrumented antenna to search for gravitational waves predicted by Einstein's general theory of relativity. Tidal deformation of the moon was measured. Gravitational radiation is a channel that is capable of giving information about the structure and evolution of the universe.

Giganti, J. J.

Lunar Surface Gravimeter Experiment

The lunar surface gravimeter which was emplaced on the moon by the Apollo 17 flight is described and a schematic diagram of the sensor is provided. The objective of the lunar surface gravimeter is to use the moon as an instrumented antenna to detect gravitational waves. Another objective is to measure tidal deformation of the moon. Samples of signals received during lunar sunrise activity and during quiet periods are presented in graph form based on power spectrum analysis

Giganti, J. J.

Gravitational waves.

Gravitational wave detection covering principles and technique for measuring Riemann curvature tensor, noting gravimeter system diagram

Weber, J.

Gravitational shielding and absorption.

Gravitational shielding and absorption, examining tidal effects induced in solid sphere by another sphere, analogy to electromagnetic fields, etc

ELECTROMAGNETIC FIELD