Engineering Papers⌕ Search

Engineering topics

Webb, Micah

Publications and source records attributed to Webb, Micah.

GRid Analysis and Visualization Interface (GRAVI) [SWR-24-16]

GRAVI (GRid Analysis and Visualization Interface) is a web application for viewing and analyzing nodal Production Cost Model (PCM) and Capacity Expansion Model (CEM) simulations. The web application provides the ability to animate geospatially coupled timeseries data in an agnostic way regardless of the underlying simulation tool used to generate the data. GRAVI also provides capabilities to animate non-geospatial data relevant to a PCM or CEM model. Furthermore, this web application can be tailored as an real-time operational tool to better understand a live grid.

Webb, Micah↗

High broadband photoconductivity of few-layered MoS 2 field-effect transistors measured using multi-terminal methods: effects of contact resistance

Among the layered two dimensional semiconductors, molybdenum disulfide (MoS 2 ) is considered to be an excellent candidate for applications in optoelectronics and integrated circuits due to its layer-dependent tunable bandgap in the visible region, high ON/OFF current ratio in field-effect transistors (FET) and strong light–matter interaction properties. In this study, using multi-terminal measurements, we report high broadband photocurrent response ( R ) and external quantum efficiency (EQE) of few-atomic layered MoS 2 phototransistors fabricated on a SiO 2 dielectric substrate and encapsulated with a thin transparent polymer film of Cytop. The photocurrent response was measured using a white light source as well as a monochromatic light of wavelength λ = 400 nm–900 nm. We measured responsivity using a 2-terminal configuration as high as R = 1 × 10 3 A W -1 under white light illumination with an optical power P opt = 0.02 nW. The R value increased to 3.5 × 10 3 A W -1 when measured using a 4-terminal configuration. Using monochromatic light on the same device, the measured values of R were 10 3 and 6 × 10 3 A W -1 under illumination of λ = 400 nm when measured using 2- and 4-terminal methods, respectively. The highest EQE values obtained using λ = 400 nm were 10 5 % and 10 6 % measured using 2- and 4-terminal configurations, respectively. The wavelength dependent responsivity decreased from 400 nm to the near-IR region at 900 nm. The observed photoresponse, photocurrent–dark current ratio (PDCR), detectivity as a function of applied gate voltage, optical power, contact resistances and wavelength were measured and are discussed in detail. The observed responsivity is also thoroughly studied as a function of contact resistance of the device.

36 MATERIALS SCIENCE↗