Engineering Papers⌕ Search

Engineering topics

Watson, Robert

Publications and source records attributed to Watson, Robert.

Panel Session 24B: Records, Knowledge, and Memory for Radioactive Waste Repositories: Generational Equity Focus

This panel focused on the latest thoughts, ideas, and methodologies being explored throughout the world on how to communicate with future generations regarding nuclear waste disposal. Scientists determined many years ago that geological disposal in a repository was the preferred solution for nuclear waste disposal given the longevity concerns of the waste(s). Future generations must be informed through records, memory keeping and permanent markers to ensure they are aware of, and knowledgeable of, the dangers associated with nuclear waste isolated from the biosphere. Panelists with presentations: You Want to Drill Where? Human Intrusion Messaging Considerations (Thomas Peake, Jonathan Major); Ethical Reflections on the Basic Reasons for RK and M Measures (Carl-Reinhold Brakenhielm); NEA Activities on Information, Data and Knowledge Management (Rebecca Tadesse); Records, Knowledge and Memory (RK and M) Across Generations: Recent Activities and Progress in Sweden (Claudio Pescatore)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Testing of a Membrane CO 2 Capture Process with a Coal-Fired Boiler

This final technical report describes work conducted by Membrane Technology and Research, Inc. (MTR) for the Department of Energy, National Energy Technology Laboratory (DOE NETL) to demonstrate integrated operation of the MTR small pilot membrane CO 2 capture system with Babcock & Wilcox Enterprises, Inc.’s (B&W) Small Boiler Simulator-II (SBS-II) pilot coal boiler (award number DE-FE0026414). The work was performed from July 1, 2015 through March 31, 2018. The overall goal of this project was to operate the existing MTR small pilot membrane CO 2 capture system at an appropriately-sized coal-fired boiler to test integrated operation with CO 2 recycle to the boiler. MTR was assisted in this project by B&W, which hosted the integrated membrane-boiler field test at the B&W Research Facility in Barberton, OH. This report details the work performed to prepare the B&W site, modify the existing MTR membrane system, install the MTR system at B&W, and operate an integrated membrane-boiler field test with CO 2 recycle to the boiler. Detailed analysis of the integrated membrane-boiler test data was conducted to validate prior B&W computational fluid dynamics (CFD) modeling and SBS-II boiler tests with CO 2 -laden air that showed modest effects of recycled CO 2 on boiler performance. The integrated test results also demonstrated how various membrane parameters impact the performance of a dynamic boiler system. Key results for all tasks and recommendations for future research are discussed in this report.

20 FOSSIL-FUELED POWER PLANTS↗

Ethical Considerations in Determining the Societal Investment in Warning Future Generations about Latent Long-term Risks from Radioactive Waste Disposal Facilities - 17058

Writers and philosophers have long romanticized and pondered the great challenge of communicating with future generations. The only way that man can travel through time. Never has this notion been more studied and debated than in the nuclear waste disposal arena. Regulatory requirements in the United States and internationally, require that there be some form of notification of future generations in place once a deep geologic nuclear waste repository has been closed. It is considered a generational responsibility. Since the difficulty of this task is so daunting, it has been assumed that the monetary cost to accomplish this millennia-spanning message-in-a-bottle must also be extreme. This paper will discuss both the ethical and equitable implications across generations, as they pertain to the reality of future inadvertent intrusion scenarios and the associated cost of communicating through time to prevent them. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Practical Considerations for the Implementation of a World Information Library (WIL) - 17112

The U.S. Department of Energy's (DOE) Waste Isolation Pilot Plant (WIPP) is a deep geologic repository for the permanent disposal of defense-generated transuranic waste. Title 40 Code of Federal Regulations (CFR) Part 194.43, Passive institutional controls, requires that measures be employed, '...to preserve knowledge about the location, design, and contents of the [WIPP] disposal system'. These measures include the, 'Placement of records in the archives and land record systems of local, State, and Federal governments, as well as international archives, that would likely be consulted by individuals in search of unexploited resources'. One possibility for allowing individuals to quickly and easily access information on the location, design, and contents of a disposal system and its relation to unexploited resources is the development of an electronic geographic information system (GIS) that would be used to interpret spatial data. In 2016, R. Patterson proposed such a system, known as the 'World Information Library (WIL)'. Information in this database system would be designed to be publicly accessible through a simple web-based user interface that would focus on spatial databases with categories such as; waste repositories, resources, historical sites, wildlife, infrastructure, medicine, agriculture, and technology. The conceptual WIL would be a compilation of searchable libraries and databases. A category in the WIL would consist of spatial databases created for the purpose of preserving knowledge and providing a means of communicating location information in a GIS-based Land Use Information System (LUIS) user interface. The successful implementation of the WIL would require the robust use of project controls, an effective Quality Assurance program, and the development of international standards in collaboration with industry experts. The purpose of this paper is to identify and discuss known practices and industry standards that could be utilized for the implementation of a WIL as was introduced by Patterson et al. in 'A Conceptual World Information Library (WIL) and Land Use Information System (LUIS)'. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

There is Nothing Here for You: Passive Institutional Controls and Preemptive Resource Exploitation - 16197

The Department of Energy (DOE) Carlsbad Field Office (CBFO) is required by Title 40 CFR Part 191.14(c) and Title 40 CFR Part 194.43 to develop a Passive Institutional Controls (PICs) program to prevent the likelihood for future human intrusion into the Waste Isolation Pilot Plant (WIPP). The purpose of this paper is to explore how the exploitation of resources under nuclear waste repositories as a part of PICs could reduce the risk of future human intrusion. The WIPP, located in the northern Permian Basin near Carlsbad, New Mexico, is a geologic repository for the permanent isolation of defense-related transuranic waste. In 1995, a series of geophysical surveys by the New Mexico Bureau of Mines and Mineral Resources estimated the total hydrocarbon reserves underneath the WIPP, which included a 16-section area plus a one mile buffer. Since that time the Delaware Basin well database has been maintained to closely monitor hydrocarbon extraction activities. The database was used in compiling relevant oil and gas extraction data retrieved from The New Mexico Oil Conservation Division. The volume of hydrocarbons extracted from 1995 to the present suggests that if current extraction growth trends continue (as historic market and production data indicate they will), all known crude oil reserves under the WIPP, obtainable through current extraction technology, will be depleted within approximately 10 years, i.e., by 2026. This is well before the anticipated WIPP closure and start of the Active Institutional Controls (AICs) program called for in 40 CFR Part 194.41(b). In addition, gas resources, although more difficult to forecast, are not expected to last beyond 2137. Title 40 CFR 194.33 states, 'Inadvertent and intermittent intrusion by drilling for resources... is the most severe human intrusion scenario'. This human intrusion scenario is the feature, event, and process (FEP) that performance assessment (PA) has identified as having the most significant impact on radionuclide releases during the 10,000 year regulatory period for the WIPP. Title 40 CFR 194.43 requires a PICs program which contains '... [records] in the international archives that would likely be consulted by individuals in search of unexploited resources'. Due to political, social, and economic motivators for resource exploration and exploitation, the potential future absence of hydrocarbon resources under the WIPP is important in deterring possible human intrusion. To minimize the risk of future human intrusion, it may be necessary to consider actively removing as many of the exploitable hydrocarbon resources under and around a nuclear waste repository as is practicable before the end of the period of AICs (i.e., 100 years after closure of the repository). Additionally, communicating the absence of hydrocarbon resources under a nuclear repository should take a prominent role in any PICs program. Due to its high-cost nature, exploratory drilling of any kind currently involves cost/benefit analysis. If in the future the economic realities of resource exploration remain similar to today, and future oil companies know the resources for a particular area have already been heavily exploited, hypothetically, they would become less motivated to drill in that area. They would instead opt to explore an area with better prospects. It is important then that the remaining hydrocarbon reserves be clearly stated and prominently displayed. In essence we should communicate the message, loud and clear, 'There is nothing here for you'. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pilot testing of a membrane system for postcombustion CO 2 capture

This final report summarizes work conducted for the U.S. Department of Energy, National Energy Technology Laboratory (DOE) to scale up an efficient post-combustion CO 2 capture membrane process to the small pilot test stage (award number DE-FE0005795). The primary goal of this research program was to design, fabricate, and operate a membrane CO 2 capture system to treat coal-derived flue gas containing 20 tonnes CO 2 /day (20 TPD). Membrane Technology and Research (MTR) conducted this project in collaboration with Babcock and Wilcox (B&W), the Electric Power Research Institute (EPRI), WorleyParsons (WP), the Illinois Sustainable Technology Center (ISTC), Enerkem (EK), and the National Carbon Capture Center (NCCC). In addition to the small pilot design, build and slipstream testing at NCCC, other project efforts included laboratory membrane and module development at MTR, validation field testing on a 1 TPD membrane system at NCCC, boiler modeling and testing at B&W, a techno-economic analysis (TEA) by EPRI/WP, a case study of the membrane technology applied to a ~20 MWe power plant by ISTC, and an industrial CO 2 capture test at an Enerkem waste-to-biofuel facility. The 20 TPD small pilot membrane system built in this project successfully completed over 1,000 hours of operation treating flue gas at NCCC. The Polaris™ membranes used on this system demonstrated stable performance, and when combined with over 10,000 hours of operation at NCCC on a 1 TPD system, the risk associated with uncertainty in the durability of postcombustion capture membranes has been greatly reduced. Moreover, next-generation Polaris membranes with higher performance and lower cost were validation tested on the 1 TPD system. The 20 TPD system also demonstrated successful operation of a new low-pressure-drop sweep module that will reduce parasitic energy losses at full scale by as much as 10 MWe. In modeling and pilot boiler testing, B&W confirmed the viability of CO 2 recycle to the boiler as envisioned in the MTR process design. The impact of this CO 2 recycle on boiler efficiency was quantified and incorporated into a TEA of the membrane capture process applied to a full-scale power plant. As with previous studies, the TEA showed the membrane process to be lower cost than the conventional solvent capture process even at 90% CO 2 capture. A sensitivity study indicates that the membrane capture cost decreases significantly if the 90% capture requirement is relaxed. Depending on the process design, a minimum capture cost is achieved at 30-60% capture, values that would meet proposed CO 2 emission regulations for coal-fired power plants. In summary, this project has successfully advanced the MTR membrane capture process through small pilot testing (technology readiness level 6). The technology is ready for future scale-up to the 10 MWe size.

01 COAL, LIGNITE, AND PEAT↗

Hardware Implementation of a Bilateral Subtraction Filter

A bilateral subtraction filter has been implemented as a hardware module in the form of a field-programmable gate array (FPGA). In general, a bilateral subtraction filter is a key subsystem of a high-quality stereoscopic machine vision system that utilizes images that are large and/or dense. Bilateral subtraction filters have been implemented in software on general-purpose computers, but the processing speeds attainable in this way even on computers containing the fastest processors are insufficient for real-time applications. The present FPGA bilateral subtraction filter is intended to accelerate processing to real-time speed and to be a prototype of a link in a stereoscopic-machine- vision processing chain, now under development, that would process large and/or dense images in real time and would be implemented in an FPGA. In terms that are necessarily oversimplified for the sake of brevity, a bilateral subtraction filter is a smoothing, edge-preserving filter for suppressing low-frequency noise. The filter operation amounts to replacing the value for each pixel with a weighted average of the values of that pixel and the neighboring pixels in a predefined neighborhood or window (e.g., a 9 9 window). The filter weights depend partly on pixel values and partly on the window size. The present FPGA implementation of a bilateral subtraction filter utilizes a 9 9 window. This implementation was designed to take advantage of the ability to do many of the component computations in parallel pipelines to enable processing of image data at the rate at which they are generated. The filter can be considered to be divided into the following parts (see figure): a) An image pixel pipeline with a 9 9- pixel window generator, b) An array of processing elements; c) An adder tree; d) A smoothing-and-delaying unit; and e) A subtraction unit. After each 9 9 window is created, the affected pixel data are fed to the processing elements. Each processing element is fed the pixel value for its position in the window as well as the pixel value for the central pixel of the window. The absolute difference between these two pixel values is calculated and used as an address in a lookup table. Each processing element has a lookup table, unique for its position in the window, containing the weight coefficients for the Gaussian function for that position. The pixel value is multiplied by the weight, and the outputs of the processing element are the weight and pixel-value weight product. The products and weights are fed to the adder tree. The sum of the products and the sum of the weights are fed to the divider, which computes the sum of products the sum of weights. The output of the divider is denoted the bilateral smoothed image. The smoothing function is a simple weighted average computed over a 3 3 subwindow centered in the 9 9 window. After smoothing, the image is delayed by an additional amount of time needed to match the processing time for computing the bilateral smoothed image. The bilateral smoothed image is then subtracted from the 3 3 smoothed image to produce the final output. The prototype filter as implemented in a commercially available FPGA processes one pixel per clock cycle. Operation at a clock speed of 66 MHz has been demonstrated, and results of a static timing analysis have been interpreted as suggesting that the clock speed could be increased to as much as 100 MHz.

Huertas, Andres↗

Multiple Embedded Processors for Fault-Tolerant Computing

A fault-tolerant computer architecture has been conceived in an effort to reduce vulnerability to single-event upsets (spurious bit flips caused by impingement of energetic ionizing particles or photons). As in some prior fault-tolerant architectures, the redundancy needed for fault tolerance is obtained by use of multiple processors in one computer. Unlike prior architectures, the multiple processors are embedded in a single field-programmable gate array (FPGA). What makes this new approach practical is the recent commercial availability of FPGAs that are capable of having multiple embedded processors. A working prototype (see figure) consists of two embedded IBM PowerPC 405 processor cores and a comparator built on a Xilinx Virtex-II Pro FPGA. This relatively simple instantiation of the architecture implements an error-detection scheme. A planned future version, incorporating four processors and two comparators, would correct some errors in addition to detecting them.

Bolotin, Gary↗