Engineering Papers⌕ Search

Engineering topics

Watkins, M.

Publications and source records attributed to Watkins, M..

At least 19 records

A heterodyne dispersion interferometer for wide bandwidth density measurements on DIII-D

In order to improve both the density and particularly the temporal resolution beyond previous dispersion interferometers (DIs), a heterodyne technique based on an acousto-optic (AO) cell has been added to the DI. A 40 MHz drive frequency for the AO cell allows density fluctuation measurements into the MHz range. A CO 2 laser-based heterodyne DI (HDI) installed on DIII-D has demonstrated that the HDI is capable of tracking the density evolution throughout DIII-D discharges, including disruption events and other rapid transient phenomena. The data also show good agreement with independent density measurements obtained with the existing DIII-D two-color interferometer. The HDI line-integrated density resolution sampled over a 1 s interval is ~9 × 10 17 m -2 . Density fluctuations induced by MHD instabilities are also successfully measured by the HDI.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tests of a full-scale ITER toroidal interferometer and polarimeter (TIP) prototype on the DIII-D tokamak (invited)

A full-scale ITER toroidal interferometer and polarimeter (TIP) prototype, including an active feedback alignment system, has been installed and tested on the DIII-D tokamak. In the TIP prototype, a two-color interferometry measurement of line-integrated density is carried out at 10.59 μm and 5.22 μm using a CO 2 and quantum cascade laser, respectively, while a separate polarimetry measurement of the plasma-induced Faraday effect is made at 10.59 μm. The TIP prototype is equipped with a piezo tip/tilt stage active feedback alignment system that minimizes noise in the measurement and keeps the diagnostic aligned throughout DIII-D discharges. The measured phase resolution for the polarimeter and interferometer is 0.05° (100 Hz bandwidth) and 1.9° (1 kHz bandwidth), respectively. Here, the corresponding line-integrated density resolution for the vibration-compensated interferometer is δnL = 1.5 × 10 18 m -2 , and the magnetic field-weighted line-integrated density from the polarimeter is δnBL = 1.5 × 10 19 Tm -2 . Both interferometer and polarimeter measurements during DIII-D discharges compare well with the expectations based on calculations using Thomson scattering measured density profiles and magnetic equilibrium reconstructions. Additionally, larger bandwidth interferometer measurements show that the diagnostic is a sensitive monitor of core density fluctuations with demonstrated measurements of Alfvén eigenmodes and tearing modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bench testing of a heterodyne CO 2 laser dispersion interferometer for high temporal resolution plasma density measurements

Here, a heterodyne detection scheme is combined with a 10.59 μm CO 2 laser dispersion interferometer for the first time to allow large bandwidth measurements in the 10-100 MHz range. The approach employed utilizes a 40 MHz acousto-optic cell operating on the frequency doubled CO 2 beam which is obtained using a high 2nd harmonic conversion efficiency orientation patterned gallium arsenide crystal. The measured standard deviation of the line integrated electron density equivalent phase resolution obtained with digital phase demodulation technique, is 4 × 10 17 m –2 . Air flow was found to significantly affect the baseline of the phase signal, which an optical table cover was able to reduce considerably. The heterodyne dispersion interferometer (DI) approach is found to be robustly insensitive to motion, with measured phase shifts below baseline drifts even in the presence of several centimeters of retroreflector induced path length variations. Plasma induced dispersion was simulated with a wedged ZnSe plate and the measured DI phase shifts are consistent with expectations.

47 OTHER INSTRUMENTATION↗

Gamma ray imager on the DIII-D tokamak

A gamma ray camera is built for the DIII-D tokamak [J. Luxon, Nucl. Fusion 42, 614 (2002)] that provides spatial localization and energy resolution of gamma flux by combining a lead pinhole camera with custom-built detectors and optimized viewing geometry. This diagnostic system is installed on the outer midplane of the tokamak such that its 123 collimated sightlines extend across the tokamak radius while also covering most of the vertical extent of the plasma volume. A set of 30 bismuth germanate detectors can be secured in any of the available sightlines, allowing for customizable coverage in experiments with runaway electrons in the energy range of 1–60 MeV. Commissioning of the gamma ray imager includes the quantification of electromagnetic noise sources in the tokamak machine hall and a measurement of the energy spectrum of background gamma radiation. First measurements of gamma rays coming from the plasma provide a suitable testbed for implementing pulse height analysis that provides the energy of detected gamma photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and characterization of the lithium beam diagnostic on DIII-D

The 30 keV lithium beam diagnostic on DIII-D is suitable to measure both the radial electron density and poloidal magnetic field profiles in the pedestal. The refurbished system features a new setup to measure the Doppler shift allowing accurate alignment of the spectral filters. The injector has been optimized to generate a stable lithium neutral beam with a current of I= 15−20 mA and a diameter of 1.9 ± 0.1 cm measured by beam imaging. The typical temporal resolution is Δt= 1−10 ms and the radial resolution of ΔR= 5 mm is given by the optical setup. A new analysis technique based on fast Fourier transform avoids systematic error contributions from the digital lock-in analysis and accounts intrinsically for background light correction. Latest upgrades and a detailed characterization of the system are presented. Proof-of-principle measurements of the poloidal magnetic field with a statistical error of typically 2% show a fair agreement with the predictions modeled with the Grad-Shafranov equilibrium solver EFIT within 4%.

43 PARTICLE ACCELERATORS↗

Embedded calibration system for the DIII-D Langmuir probe analog fiber optic links

This paper describes a generally applicable technique for simultaneously measuring offset and gain of 64 analog fiber optic data links used for the DIII-D fixed Langmuir probes by embedding a reference voltage waveform in the optical transmitted signal before every tokamak shot. The calibrated data channels allow calibration of the power supply control fiber optic links as well. The array of fiber optic links and the embedded calibration system described here makes possible the use of superior modern data acquisition electronics in the control room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GRACE: millimeters and microns in orbit

The Gravity Recovery and Climate Experiment launched March 17, 2002. The GPS data for this experiment are processed to contribute to the recover long wavelength gravity field; remove errors due to long term on-board oscillator drift; and align K/Ka-band measurments between the two spacecraft to 0.1 ns. This paper will concentrate on the use of GPS for these timing and calibration functions and will not address the recovery of the gravity field.

GRACE GPS K/Ka-band↗

Global Geophysical Fluids Center of IERS

The Global Geophysical Fluids Center (GGFC) and its seven Special Bureaus (SB, for Atmosphere, Oceans, Tides, Hydrology, Mantle, Core and Gravity/Geocenter) were establishes by the International Earth Rotation Service in 1998, to support global geodynamic research. Mass transports in the geophysical fluids of the Earth system will cause observable geodynamic effects on a broad time scale.These include (1) variations in the solid Earth's rotation (in length-of-day and polar motion/nutation) via the conservation of angular momentum and effected by torques at the fluid-solid Earth interface; (2) changes in the global gravitational field according to Newton's gravitational law; and (3) motion in the center of mass of the solid Earth relative to that of the whole Earth ("geocenter") via the conservation of linear momentum. These minute signals have become observable by space geodetic techniques, primarily VLBI, SLR, GPS, and DORIS, and new exciting data will be available by space gravity, altimetry, SAR, and magnetic missions. In this sense the precise space geodetic techniques have become effective means of remote sensing of global mass transports. The GGFC and its SBs have the responsibility of supporting, facilitating, and providing services to the worldwide research community in the related research areas. We compute, analyze, compare, archive, and disseminate the time series of the angular momenta and the related torques, gravitational coefficients, and geocenter shift for all geophysical fluids, based on global observational data, and/or products from state-of-the-art models some of which assimilate such data. The computed quantities, algorithm and data formats are standardized. This paper reviews our activities, reports the status, and looks forward into the future.

Chao, Benjamin F.↗

Monitoring Global Geophysical Fluids by Space Geodesy

Since its establishment on 1/1/1998 by the International Earth Rotation Service, the Coordinating Center for Monitoring Global Geophysical Fluids (MGGF) and its seven Special Bureaus have engaged in an effort to support and facilitate the understanding of the geophysical fluids in global geodynamics research. Mass transports in the atmosphere-hydrosphere-solid Earth-core system (the "global geophysical fluids") will cause the following geodynamic effects on a broad time scale: (1) variations in the solid Earth's rotation (in length-of-day and polar motion/nutation) via the conservation of angular momentum and effected by torques at the fluid-solid Earth interface; (2) changes in the global gravitational field according to Newton's gravitational law; and (3) motion in the center of mass of the solid Earth relative to that of the whole Earth ("geocenter") via the conservation of linear momentum. These minute signals have become observable by space geodetic techniques, primarily VLBI, SLR, GPS, and DORIS, with ever increasing precision/accuracy and temporal/spatial resolution. Each of the seven Special Bureaus within MGGF is responsible for calculations related to a specific Earth component or aspect -- Atmosphere, Ocean, Hydrology, Ocean Tides, Mantle, Core, and Gravity/Geocenter. Angular momenta and torques, gravitational coefficients, and geocenter shift will be computed for geophysical fluids based on global observational data, and from state-of-the-art models, some of which assimilate such data. The computed quantities, algorithm and data formats are standardized. The results are archived and made available to the scientific research community. This paper reports the status of the MGGF activities and current results.

Chao, Benjamin F.↗