Engineering PapersSearch

Engineering topics

Wasserbauer, J. F.

Publications and source records attributed to Wasserbauer, J. F..

At least 19 records

Experimental Investigation of the Performance of a Mach-2.7 Two-dimensional Bifurcated Duct Inlet with 30 Percent Internal Contraction

An experimental study was conducted to determine the performance of a two-dimensional, mixed-compression bifurcated duct inlet system designed for a free-stream Mach number of 2.7. Thirty percent of the supersonic area contraction occurred internally. A movable ramp was used to vary the contraction ratio for off-design operation. Boundary layer bleed regions were located on the cowl, centerbody, and sidewall surfaces. There were also provisions for vortex generators on the cowl and centerbody of the subsonic diffuser. Data were obtained over the Mach number range of 2.0 to 2.8 and at angles of yaw from 0 deg. to the maximum value prior to inlet un-start. The test at Mach 2.8 was to obtain data for an over- speed condition. The Reynolds number varied from 2.5 to 2.3 million/ft for Mach numbers above 2.5. At Mach numbers of 2.5 and lower, the Reynolds number was set at 2.5 million/ft. Bleed patterns, vortex generator patterns, and ramp position were varied, and three inlet configurations were selected for more extensive study. Two of these configurations had self-starting capability. The self-starting configuration that was developed produced 89 percent total pressure recovery at the compressor face station with 6.8 percent total bleed. The compressor face distortion was about 16 percent. Vortex generators were extremely effective in re-distributing flow but were not as effective in reducing distortion. Excellent flow symmetry was achieved between the separated halves of the inlet, and twin-duct instability was not observed. The ramp tip shock was steeper than expected. This caused the cowl lip shock to be reflected from the ramp instead of being cancelled at the shoulder. However, peak recovery at the throat was still obtained with the ramp near the design position.

Wasserbauer, J. F.

Performance and surge limits of a TF30-P-3 turbofan engine/axisymmetric mixed-compression inlet propulsion system at Mach 2.5

Steady-state performance and inlet-engine compatibility were investigated with a low-bleed inlet. The inlet had minimum internal contraction, consistent with high total pressure recovery and low cowl drag. The inlet-engine combination displayed good performance with only about 2% of inlet performance bleed. The inlet-engine combination had 5.58 deg angle-of-attack capability with 6% bleed.

Wasserbauer, J. F.

Low speed performance of a supersonic axisymmetric mixed compression inlet with auxiliary inlets

The aerodynamic performance of a representative supersonic cruise inlet was investigated using a fan simulator coupled to the inlet to provide characteristic noise signatures and to pump the inlet flow. Data were obtained at Mach numbers from 0 to 0.2 for the inlet equipped with an auxiliary inlet system that provided 20 to 40 percent of the fan flow. Results show that inlet performance improved when the inlet bleed systems were sealed; when the freestream Mach number was increased; and when the auxiliary inlets were opened. The inlet flow could not be choked by either centerbody translation or by increasing the fan speed when the 40 percent auxiliary inlet was incorporated. Previously announced in STAR as N83-27992

Wasserbauer, J. F.

Low speed performance of a supersonic axisymmetric mixed compression inlet with auxiliary inlets

The aerodynamic performance of a representative supersonic cruise inlet was investigated using a fan simulator coupled to the inlet to provide characteristic noise signatures and to pump the inlet flow. Data were obtained at Mach numbers from 0 to 0.2 for the inlet equipped with an auxiliary inlet system that provided 20 to 40 percent of the fan flow. Results show that inlet performance improved when the inlet bleed systems were sealed; when the freestream Mach number was increased; and when the auxiliary inlets were opened. The inlet flow could not be choked by either centerbody translation or by increasing the fan speed when the 40 percent auxiliary inlet was incorporated.

Wasserbauer, J. F.

Inlet-engine matching for SCAR including application of a bicone variable geometry inlet

Airflow characteristics of variable cycle engines (VCE) designed for Mach 2.32 can have transonic airflow requirements as high as 1.6 times the cruise airflow. This is a formidable requirement for conventional, high performance, axisymmetric, translating centerbody mixed compression inlets. An alternate inlet is defined where the second cone of a two cone centerbody collapses to the initial cone angle to provide a large off-design airflow capability, and incorporates modest centerbody translation to minimize spillage drag. Estimates of transonic spillage drag are competitive with those of conventional translating centerbody inlets. The inlet's cruise performance exhibits very low bleed requirements with good recovery and high angle of attack capability.

Wasserbauer, J. F.

Inlet-engine matching for SCAR including application of a bicone variable geometry inlet

Airflow characteristics of variable cycle engines (VCE) designed for Mach 2.32 can have transonic airflow requirements as high as 1.6 times the cruise airflow. This is a formidable requirement for conventional, high performance, axisymmetric, translating centerbody mixed compression inlets. An alternate inlet is defined, where the second cone of a two cone center body collapses to the initial cone angle to provide a large off-design airflow capability, and incorporates modest centerbody translation to minimize spillage drag. Estimates of transonic spillage drag are competitive with those of conventional translating centerbody inlets. The inlet's cruise performance exhibits very low bleed requirements with good recovery and high angle of attack capability.

Wasserbauer, J. F.

Boundary layer bleed system study for a full-scale, mixed-compression inlet with 45 percent internal contraction

The results of an experimental bleed development study for a full-scale, Mach 2.5, axisymmetric, mixed-compression inlet were presented. The inlet was designed to satisfy the airflow requirements of the TF30-P-3 turbofan engine. Capabilities for porous bleed on the cowl surface and ram-scoop/flush-slot bleed on the centerbody were provided. A configuration with no bleed on the cowl achieved a minimum stable, diffuser exit, total pressure recovery of 0.894 with a centerbody-bleed mass flow ratio of 0.02. Configurations with cowl bleed had minimum stable recoveries as high as 0.900 but suffered range decrement penalties from the increased bleed mass flow removal. Limited inlet stability and unstart angle-of-attack data are presented.

Shaw, R. J.

Performance of vortex generators in a Mach 2.5 low-bleed full scale 45-percent-internal-contraction axisymmetric inlet

Steady-state and dynamic flow characteristics associated with two sets of vortex generators having different mixing criteria were determined. The inlet performance with and without these vortex generators is presented. The vortex generators were successful in eliminating separation, increasing area-weighted total pressure recovery, and decreasing distortion. Transmission times obtained from cross-correlations of the wall static pressures and the diffuser exit total pressure showed no effect of the upstream flow characteristics on the diffuser exit pressures when generators were used. Without generators, separation occurred and the upstream pressure characteristics had immediate effects on the diffuser exit pressure characteristics.

Neumann, H. E.

Design of a very-low-bleed Mach 2.5 mixed-compression inlet with 45 percent internal contraction

A full-scale, mixed-compression inlet was designed for operation with the TF30-P-3 turbofan engine and tested at Mach numbers of 2.5 and 2.0. The two-cone axisymmetric inlet had minimum internal contraction consistent with high total pressure recovery and low cowl drag. At Mach 2.5, inlet recovery was 0.906 with only 0.021 centerbody bleed mass-flow ratio and no cowl bleed. Increased centerbody bleed gave a maximum inlet unstart angle of attack of 6.85 deg. At Mach 2.0, inlet recovery was 0.94 with only 0.014 centerbody bleed mass-flow ratio and no cowl bleed. Inlet performance and angle-of-attack tolerance is presented for operation at Mach numbers of 2.5 and 2.0.

Wasserbauer, J. F.

Distortion in a full-scale bicone inlet with internal focused compression and 45 percent internal contraction

The distortion characteristics were investigated at the subsonic diffuser exit of a full-scale, Mach 2.5, axisymmetric, mixed compression inlet. Performance and steady-state distortion characteristics were obtained at zero and maximum angle of attack and during an inlet unstart-restart sequence. For the configuration with no cowl bleed, steady-state distortion P(max)P(min)P(bar) ranged from 0.10 for critical inlet operation at 0 deg angle-of-attack to 0.306 for supercritical inlet operation at 6.84 deg angle-of-attack. Vortex generators provided a 50 percent reduction in steady-state distortion for critical operation. Bleed has a smaller effect on steady-stated distortion.

Wasserbauer, J. F.

Minimizing boundary layer bleed for a mixed compression inlet

An experimental investigation of a full scale mixed compression inlet sized for the TF30-P-3 turbofan engine was conducted at Mach 2.5 and 2.0 operating conditions. The two cone axisymmetric inlet had minimum internal contraction consistent with high total pressure recovery and low cowl drag. At Mach 2.5, inlet recovery exceeded 0.90 with only 0.02 centerbody bleed mass-flow ratio and zero cowl bleed. A centerbody bleed of approximately 0.05 gave a maximum inlet unstart angle-of-attack of 6.85 deg. Inlet performance and angle-of-attack tolerance is presented for operation at Mach 2.5 and 2.0.

Wasserbauer, J. F.

Minimizing boundary layer bleed for a mixed compression inlet

An experimental investigation of a full scale mixed compression inlet sized for the TF30-P-3 turbofan engine was conducted at Mach 2.5 and 2.0 operating conditions. The two cone axisymmetric inlet had minimum internal contraction consistent with high total pressure recovery and low cowl drag. At Mach 2.5, inlet recovery exceeded 0.90 with only 0.02 centerbody bleed mass-flow ratio and zero cowl bleed. A centerbody bleed of approximately 0.05 gave a maximum inlet unstart angle-of-attack of 6.85 deg. Inlet performance and angle-of-attack tolerance is presented for operation at Mach 2.5 and 2.0.

Wasserbauer, J. F.

Performance of a bicone inlet designed for Mach 2.5 with internal distributed compression and 40 percent internal contraction

The inlet was designed to have the minimum internal contraction consistent with high total-pressure recovery and low cowl drag. Without a bypass system, the peak pressure recoveries increased from 0.890 to 0.936 when the supercritical bleed mass flow ratio was varied from 0.035 to 0.060. With an operating bypass system and installed centerbody vortex generators, a slight increase in peak pressure recovery was obtained. The values of steady-state distortion and dynamic distortion were below 0.10 and 0.02, respectively, near critical operation. Simulation of a turbofan engine with concentric pipes showed no effect on compressor face flow profiles with varying bypass flow ratio.

Wasserbauer, J. F.