Engineering Papers⌕ Search

Engineering topics

Warwick, Tony

Publications and source records attributed to Warwick, Tony.

At least 19 records

Ex situ metrology and data analysis for optimization of beamline performance of aspherical pre-shaped x-ray mirrors at the advanced light source

Super high quality aspherical x-ray mirrors with a residual slope error of ~100 nrad (root-mean-square) and a height error of ~1-2 nm (peak-to-valley), and even lower, are now available from a number of the most advanced vendors utilizing deterministic polishing techniques. The mirror specification for the fabrication is based on the simulations of the desired performance of the mirror in the beamline optical system and is normally given with the acceptable level of deviation of the mirror figure and finish from the desired ideal shape. For example, in the case of aspherical x-ray mirrors designed for the Advanced Light Source (ALS) QERLIN beamline, the ideal shape is defined with the beamline application (conjugate) parameters and their tolerances. Here, we first introduce an original procedure and dedicated software developed at the ALS X-Ray Optics Laboratory (XROL) for optimization of beamline performance of pre-shaped hyperbolic and elliptical mirrors. The optimization is based on results of ex situ surface slope metrology and consists in minimization of the mirror shape error by determining the conjugate parameters of the best-fit ideal shape within the specified tolerances. We describe novel optical metrology instrumentation, measuring techniques, and analytical methods used at the XROL for acquisition of surface slope data and optimization of the optic’s beamline performance. The high efficacy of the developed experimental methods and data analysis procedures is reflected in results of measurements with and performance optimization of hyperbolic and elliptical cylinder mirrors designed and fabricated for the ALS QERLIN beamline.

47 OTHER INSTRUMENTATION↗

Three-dimensional localization of nanoscale battery reactions using soft X-ray tomography

Battery function is determined by the efficiency and reversibility of the electrochemical phase transformations at solid electrodes. The microscopic tools available to study the chemical states of matter with the required spatial resolution and chemical specificity are intrinsically limited when studying complex architectures by their reliance on two-dimensional projections of thick material. Here in this paper, we report the development of soft X-ray ptychographic tomography, which resolves chemical states in three dimensions at 11 nm spatial resolution. We study an ensemble of nano-plates of lithium iron phosphate extracted from a battery electrode at 50% state of charge. Using a set of nanoscale tomograms, we quantify the electrochemical state and resolve phase boundaries throughout the volume of individual nanoparticles. These observations reveal multiple reaction points, intra-particle heterogeneity, and size effects that highlight the importance of multi-dimensional analytical tools in providing novel insight to the design of the next generation of high-performance devices.

25 ENERGY STORAGE↗

Radiological Protection Studies for NGLS XTOD

The X-ray transport, optics and diagnostic system (XTOD) starts from the end of bending magnets sending electrons to the main dump and ends at the end wall separating the accelerator tunnel from the user experimental hall (hereafter referred as EH wall), as shown in Figure 1. Figure 1.a shows the general schematic and Figure 1.b shows the initial layout with possible shielding components. This document summarizes the extensive studies on the shielding and collimator system design necessary to meet the radiation protection requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Near-edge X-ray refraction fine structure microscopy

We demonstrate a method for obtaining increased spatial resolution and specificity in nanoscale chemical composition maps through the use of full refractive reference spectra in soft x-ray spectro-microscopy. Using soft x-ray ptychography, we measure both the absorption and refraction of x-rays through pristine reference materials as a function of photon energy and use these reference spectra as the basis for decomposing spatially resolved spectra from a heterogeneous sample, thereby quantifying the composition at high resolution. While conventional instruments are limited to absorption contrast, our novel refraction based method takes advantage of the strongly energy dependent scattering cross-section and can see nearly five-fold improved spatial resolution on resonance.

36 MATERIALS SCIENCE↗

Soft X‐ray Ptychographic Imaging and Morphological Quantification of Calcium Silicate Hydrates (C–S–H)

Morphological details of calcium silicate hydrate (C–S–H) stemming from the hydration process of Portland cement ( PC ) phases are crucial for understanding the PC ‐based systems but are still only partially known. Here we introduce the first soft X‐ray ptychographic imaging of tricalcium silicate (C 3 S) hydration products. The results are compared using both scanning transmission X‐ray and electron transmission microscopy data. The evidence shows that ptychography is a powerful method to visualize the details of outer and inner product C–S–H of fully hydrated C 3 S, which have fibrillar and an interglobular structure with average void sizes of 20 nm, respectively. The high‐resolution ptychrography image enables us to perform morphological quantification of C–S–H, and, for the first time, to possibly distinguish the contributions of inner and outer product C–S–H to the small angle scattering of cement paste. The results indicate that the outer product C–S–H is mainly responsible for the q −3 regime, whereas the inner product C–S–H transitions to a q −2 regime. Various hypotheses are discussed to explain these regimes.

Bae, Sungchul↗

High-order multilayer coated blazed gratings for high resolution soft x-ray spectroscopy

A grand challenge in soft x-ray spectroscopy is to drive the resolving power of monochromators and spectrometers from the 10 4 achieved routinely today to well above 10 5 . This need is driven mainly by the requirements of a new technique that is set to have enormous impact in condensed matter physics, Resonant Inelastic X-ray Scattering (RIXS). Unlike x-ray absorption spectroscopy, RIXS is not limited by an energy resolution dictated by the core-hole lifetime in the excitation process. Using much higher resolving power than used for normal x-ray absorption spectroscopy enables access to the energy scale of soft excitations in matter. These excitations such as magnons and phonons drive the collective phenomena seen in correlated electronic materials such as high temperature superconductors. RIXS opens a new path to study these excitations at a level of detail not formerly possible. However, as the process involves resonant excitation at an energy of around 1 keV, and the energy scale of the excitations one would like to see are at the meV level, to fully utilize the technique requires the development of monochromators and spectrometers with one to two orders of magnitude higher energy resolution than has been conventionally possible. Here we investigate the detailed diffraction characteristics of multilayer blazed gratings. These elements offer potentially revolutionary performance as the dispersive element in ultra-high resolution x-ray spectroscopy. In doing so, we have established a roadmap for the complete optimization of the grating design. Traditionally 1st order gratings are used in the soft x-ray region, but we show that as in the optical domain, one can work in very high spectral orders and thus dramatically improve resolution without significant loss in efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conformal growth of Mo/Si multilayers on grating substrates using collimated ion beam sputtering

Deposition of multilayers on saw-tooth substrates is a key step in the fabrication of multilayer blazed gratings (MBG) for extreme ultraviolet and soft x-rays. Growth of the multilayers can be perturbed by shadowing effects caused by the highly corrugated surface of the substrates, which results in distortion of the multilayer stack structure and degradation of performance of MBGs. In this study, to minimize the shadowing effects, we used an ion-beamsputtering machine with a highly collimated atomic flux to deposit Mo/Si multilayers on saw-tooth substrates. The sputtering conditions were optimized by finding a balance between smoothening and roughening processes in order to minimize degradation of the groove profile in the course of deposition and at the same time to keep the interfaces of a multilayer stack smooth enough for high efficiency. An optimal value of energy of 200 eV for sputtering Kr + ions was found by deposition of test multilayers on flat substrates at a range of ion energies. Two saw-tooth substrates were deposited at energies of 200 eV and 700 eV for the sputtering ions. It was found that reduction of the ion energy improved the blazing performance of the MBG and resulted in a 40% gain in the diffraction efficiency due to better replication of the groove profile by the multilayer. As a result of the optimization performed, an absolute diffraction efficiency of 28.8% was achieved for the 2nd blaze order of the MBG with a groove density of 7350 lines/mm at a wavelength of 13.5 nm. Lastly, details of the growth behavior of the multilayers on flat and saw-tooth substrates are discussed in terms of the linear continuous model of film growth.

36 MATERIALS SCIENCE↗

Ultra-high efficiency multilayer blazed gratings through deposition kinetic control

Diffraction efficiency of multilayer coated blazed gratings (MBG) strongly depends on the perfection of the saw-tooth-shaped layers in the overall composite structure. Growth of multilayers on saw-tooth substrates should be carefully optimized in order to reduce groove profile distortion and at the same time to avoid significant roughening of multilayer interfaces. In this work we report on a new way to optimize growth of sputter-deposited Mo/Si multilayers on saw-tooth substrates through variation of the sputtering gas pressure. Lastly, a new record for diffraction efficiency of 44% was achieved for a optimized MBG with groove density of 5250 lines /mm at the wavelength of 13.1 nm.

36 MATERIALS SCIENCE↗