Loose Belt Fault Detection and Virtual Flow Meter Development Using Identified Data-driven Energy Model for Fan Systems

An energy model that correlates fan airflow, head, speed, and system power input is essential to detect device faults and optimize control strategies in fan systems. Since the application of variable-frequency drives (VFDs) makes the motor-efficiency data published by manufacturers inapplicable for VFD–motor–fan systems, the fan efficiency and drive (belt–motor–VFD) efficiency must be identified for each individual system to obtain accurate energy models. The objectives of this paper are to identify an energy model of existing VFD–motor–fan systems using available experimental data and demonstrate its applications in loose belt fault detection and virtual airflow meter development for optimal control. First, an approach is developed to identify the fan head, fan efficiency, and drive-efficiency curves using available fan head, speed, and system power input as well as temporarily measured airflow rate without measuring shaft power. Then, the energy model is identified for an existing VFD–motor–fan system. Finally, the identified model is applied to detect the slipped belt faults and develop the virtual airflow meter. The experiment results reveal that the developed approach can effectively obtain the energy model of VFD–motor–fan systems and the model can be applied to effectively detect slipped belt faults and accurately calculate the fan airflow rate.

42 ENGINEERING↗

Evaluation of supply air temperature control performance with different control strategies at air handling units

Due to its nonlinear feature, supply air temperature control systems at air handling units using single-loop fixed gain control frequently suffer unstable response under dynamic conditions. This paper is aimed at identifying a more effective control strategy to stabilize the valve control and achieve desirable supply air temperature response under various operation conditions by evaluating three control strategies, cascade, gain scheduling and cascade plus gain scheduling controls. Firstly, a control-oriented model is developed and calibrated through open-loop tests. Then, the control issues with single-loop fixed gain control are evaluated through simulations and field tests, which indicates that the system has more aggressive response or becomes unstable under lower load conditions when the chilled-water flow rate is less than 0.1 L/s. Finally, three control strategies are proposed and evaluated. Further, the results reveal that all three proposed controls can achieve better robustness with the integral square error of supply air temperature decreased to 16%, 47% and 5%, respectively, under lower load condition. However, since high-frequency oscillation of the control valve occurs with cascade and cascade plus gain scheduling control, the gain scheduling control is recommended considering a trade-off among the supply air temperature response, valve lifetime and implementation complexity.

42 ENGINEERING↗

Evaluation of nonlinear control performance of air handling units under variable operation conditions using root distribution approach

The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.

42 ENGINEERING↗

Improving the nonlinear control performance of the supply fan at air handling units using a gain scheduling control strategy

Due to its nonlinear nature, the supply fan at air handling units with the controller tuned at the design condition tends to be aggressive and oscillate under partial load conditions. Here, the objective of this paper is to develop and validate a gain scheduling control strategy to improve its nonlinear control performance. First, a control-oriented model, which does not require numerous physical parameters and extensive test data, is developed to study the nonlinearity of the fan system. Based on the theoretical model and experimental verifications, the issue of an aggressive response with a conventional fixed-gain controller is caused by the fact that the system gain is proportional to the ratio of the duct static pressure to the fan speed. To address the issue, a scheduling function of the measurable duct static pressure and fan speed is proposed to be included in the conventional fixed-gain controller to compensate for the fan system gain variation. The gain scheduling control strategy is found to approximately maintain the identical control performance under all operation conditions. Most importantly, the gain scheduling control strategy can be readily implemented without intensive computation and additional measurements, showing a promising potential in industrial applications.

42 ENGINEERING↗