Engineering Papers⌕ Search

Engineering topics

Wang, Zhe

Publications and source records attributed to Wang, Zhe.

At least 91 records · Page 5

Two-dimensional ferromagnetic van der Waals CrCl 3 monolayer with enhanced anisotropy and Curie temperature

Among the recently widely studied van der Waals layered magnets Cr X 3 ( X = Cl, Br, I), CrCl 3 monolayer (ML) is particularly puzzling: it is shown by experiments to have only an in-plane magnetic easy axis and, furthermore, all previous first-principles calculation results contradict this. Through systematic first-principles calculations, we unveil that the in-plane shape anisotropy that dominates over the weak perpendicular magnetocrystalline anisotropy is responsible for the in-plane magnetic easy axis of CrCl 3 ML. Further, to tune the in-plane ferromagnetism of CrCl 3 ML into the desirable perpendicular one, we propose substituting Cr with isovalent tungsten (W). We find that CrWCl 6 has a strong perpendicular magnetic anisotropy and a high Curie temperature up to 76 K. Our work not only gives insight into understanding the two-dimensional ferromagnetism of van der Waals MLs but also sheds new light on engineering their performances for nanodevices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Linking human-building interactions in shared offices with personality traits

Occupant behavior influences office building energy performance. The level of human-building interactions (HBIs) in shared offices strongly influences building energy use and occupant well-being. This study explored the link between occupant personality types and their behaviors of sharing energy and environment control systems and interactions with their colleagues. Inspired by the Five-Factor Model (FFM), we classified HBI behaviors into four dimensions: willingness to share control, knowledge of control, group decision behavior, and adaptive strategies. These four variables can be mapped to the four personality traits proposed by the FFM: agreeableness, openness, extraversion, and conscientiousness. Our cluster analysis identified six behavioral patterns: average (17.7%), reserved (15.3%), environmentally friendly (16.6%), role model (24.2%), self-centered (17.2%), and mechanist (9.0%). We further applied association rules, a widely utilized machine learning technique, to discover how demographics, building-related contextual factors, and perception-attitudinal factors influence HBI behaviors. Country, control feature accessibility, and group dynamics were found to be the three most influential factors that determine occupants’ HBI behaviors. Finally, the study provides insights about building design and operation, as well as policy to promote socially and environmentally desirable HBI behaviors in a shared office environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

First Experiments: New Science Opportunities at the Spallation Neutron Source Second Target Station

Leadership in materials science underpins future technologies in energy, security, and other applications that drive this nation’s economy. Neutron scattering is among the crucial characterization techniques necessary to ensure a world-leading position in materials science for the United States. The Second Target Station (STS) at the Spallation Neutron Source (SNS) will provide transformative new capabilities for the study of a broad range of materials using neutron scattering and will support users in many fields of research—materials science, physics, chemistry, geology, biology, and engineering, among others—and from academia, government laboratories, and industry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Learning occupants’ indoor comfort temperature through a Bayesian inference approach for office buildings in United States

A carefully chosen indoor comfort temperature as the thermostat set-point is the key to optimizing building energy use and occupants’ comfort and well-being. ASHRAE Standard 55 or ISO Standard 7730 uses the PMV-PPD model or the adaptive comfort model that is based on small-sized or outdated sample data, which raises questions on whether and how ranges of occupant thermal comfort temperature should be revised using more recent larger-sized dataset. In this paper, a Bayesian inference approach has been used to derive new occupant comfort temperature ranges for U.S. office buildings using the ASHRAE Global Thermal Comfort Database. Bayesian inference can express uncertainty and incorporate prior knowledge. The comfort temperatures were found to be higher and less variable at cooling mode than at heating mode, and with significant overlapped variation ranges between the two modes. The comfort operative temperature of occupants varies between 21.9 and 25.4 °C for the cooling mode with a median of 23.7 °C, and between 20.5 and 24.9 °C for the heating mode with a median of 22.7 °C. These comfort temperature ranges are similar to the current ASHRAE standard 55 in the heating mode but 2–3 °C lower in the cooling mode. Finally, the results of this study could be adopted as more realistic thermostat set-points in building design, operation, control optimization, energy performance analysis, and policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Equivalence between Soft Star Polymers and Hard Spheres

Understanding the dynamics of soft colloids, such as star polymers, dendrimers, and microgels, is of scientific and practical importance. It is known that the excluded volume effect plays a key role in colloidal dynamics. Here, we propose a condition of compressibility equivalence that provides a simple method to experimentally evaluate the excluded volume of soft colloids from a thermodynamic view. We apply this condition to survey the dynamics of a series of star polymer dispersions. It is found that, as the concentration increases, the slowing of the long-time self-diffusivity of the star polymer, normalized by the short-time self-diffusivity, can be mapped onto the hard-sphere behavior. This phenomenon reveals the dynamic equivalence between soft colloids and hard spheres, despite the apparent complexity of the interparticle interaction of the soft colloids. The methods for measuring the osmotic compressibility and the self-diffusivities of soft colloidal dispersions are also presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-density thermal sensitivity maps of the human body

‘Personal comfort systems’ and thermally active clothing are able to warm and cool individual building occupants by transferring heat directly to and from their body surfaces. Such systems would ideally target local body surfaces with high temperature sensitivities. Such sensitivities have not been quantified in detail before. Here we report local thermal sensations and sensitivities for 318 local skin spots distributed over one side of the body, measured on a large number of subjects. Skin temperature changes were induced with a thermal probe 14 mm in diameter, and subjective thermal sensations were surveyed after 10 s. Our neutral base temperature was 31 °C and the spot stimulus was ±5 °C. Cool and warm sensitivities are seen to vary widely by body part. The foot, lower leg and upper chest are much less sensitive than average; in comparison, the cheek, neck back, and seat area are 2–3 times as sensitive to both cooling and warming stimuli. Every body part exhibits stronger sensitivity to cooling (1.3–1.6 times stronger) than to warming. Inter-personal differences and regional variance within body parts were observed to be 2–3 times greater than potential sex differences. These high-density thermal sensitivity maps with appended dataset provide the most comprehensive distributions of cold and warm sensitivity across the human body.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of thermal comfort infused with the latest big data and modeling progresses in public health

Thermal environment is important for both occupants’ comfort and health. Previously, the impacts of thermal environment were explored in the areas of thermal comfort and public health separately. This paper aims to bridge both disciplines by examining the correlation between comfort temperature and Minimum Mortality Temperature (MMT), which is a key index quantifying the association of health and weather temperature, through literature review and data-driven approach. It was found that the MMT data obtained from the public health area are generally in good agreement with the thermal neutral temperatures from the comfort perspective. The MMT data range from 17.2 °C to 30 °C, which are similar to the thermal neutral temperatures ranging from 19.5 °C to 30 °C based on the global field tests. Moreover, the MMT data demonstrate the potential to capture some complex distribution patterns of the field comfort data. The introduction of the health-temperature data could assist the intensive field experiments and modeling efforts and complement the thermal comfort dataset, which suffers from the problems of limited sample size. Some discrepancies between the two datasets were identified as well. The contextual factors other than the climate factor which may cause such discrepancies, such as socio-economics, population densities, etc. should be analyzed to enable the potential application of the health-temperature data and modeling to thermal comfort and health studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Separation of Refined Silicon from Al-Si Alloys by Air Pressure Filtration

The separation of refined silicon from Al-Si alloys through a solvent refining process was studied. Purified silicon particles were separated by air pressure filtration using stainless steel sieves as the filtration media. After the efficient removal of impurities in the refining process, the effects of the mesh number (N), separation temperature (T), silicon content in the alloy (ω{sub (a)}), and pressure differential (p) on the separation efficiency were evaluated. At N = 80, T = 873 K (600 °C), ω{sub (a)} = 45 wt pct and p = 0.25 MPa, the recovery rate of refined silicon was 98.2 pct, and the residual aluminum in the separated silicon was less than 8 wt pct. The separation process was efficient when N = 60 to 150. It was advisable for the separation temperature to approach the eutectic temperature. Efficient filtration could be achieved when ω{sub (a)} = 35 to 55 wt pct. The filtration efficiency was improved with a higher pressure differential, and the separation was efficient at p ≥ 0.10 MPa. The results show that air pressure filtration is a promising method to separate refined silicon.

36 MATERIALS SCIENCE↗

Effect of Addition of Other Acids into Butyric Acid on Selective Leaching of Zinc from Basic Oxygen Steelmaking Filter Cake

The selective leaching of zinc over iron from basic oxygen steelmaking (BOS) filter cake was investigated using mixtures of butyric acid with acetic and/or propionic acid, HCl, or H{sub 2}SO{sub 4}. The main focus was to assess the effects of other acids on the zinc and iron leaching in butyric acid. The results show that slight reduction of zinc leaching and increase in iron leaching may take place with addition of acetic and propionic acids, causing a minor decrease in the selectivity of zinc leaching over iron. Intermittent addition of H{sub 2}SO{sub 4} and HCl was required to control the pH to be not less than that of pure butyric acid solution. Overall, an excellent selectivity can be maintained with the butyric acid–other acid mixtures. The results demonstrate the feasibility to use raw butyric acid without purification or waste butyric acid containing other impurity acids for leaching of zinc from the BOS filter cake to be recycled. Using high content of H{sub 2}SO{sub 4} in leaching is not recommended because it has a more detrimental effect on the selectivity of zinc leaching and may cause deposition of CaSO{sub 4} in the leaching residue which may increase the SO{sub 2} or CO{sub 2} emission in later high-temperature recycling processes.

36 MATERIALS SCIENCE↗

Predicting plug loads with occupant count data through a deep learning approach

Predictive control has gained increasing attention for its ability to reduce energy consumption and improve occupant comfort in buildings. The plug loads prediction is a key component for the predictive building controls, as plug loads is a major source of internal heat gains in buildings. This study proposed a novel method to apply the Long-Short-Term-Memory (LSTM) Network, a special form of Recurrent Neural Network, to predict plug loads. The occupant count and the time have been confirmed to drive the plug load profile and thus selected as the features for the plug load prediction. The LSTM network was trained and tested with ground truth occupant count data collected from a real office building in Berkeley, California. Results from the LSTM network markedly improve the prediction accuracy compared with traditional linear regression methods and the classical Artificial Neural Network. 95% of 1-hour predictions from LSTM network are within ±1 kW of the actual plug loads, given the average plug loads during the office hour is 8.6 kW. The CV(RMSE) of the predicted plug load is 11% for the next hour, and 20% for the next eight hours. Lastly, we compared four prediction approaches with the office building we monitored: LSTM vs. ARIMA, with occupant counts vs. without occupant counts. It was found, the prediction error of the LSTM approach is around 4% less than the ARIMA approach. Using occupant counts as an exogenous input could further reduce the prediction error by 5%-6%. The findings of this paper could shed light on the plug load prediction for building control optimizations such as model-predictive control.

Occupant count↗

Inferring occupant counts from Wi-Fi data in buildings through machine learning

An important approach to curtail building energy consumption is to optimize building control based on occupancy information. Various studies proposed to estimate occupant counts through different approaches and sensors. However, high cost and privacy concerns remain as major barriers, restricting the practice of occupant count detection. In this study, we propose a novel method utilizing data from widely deployed Wi-Fi infrastructure to infer occupant counts through machine learning. Compared with the current indirect measurement methods, our method improves the performance of estimating people count: (1) we avoid privacy concerns by anonymizing and reshuffling the MAC addresses on a daily basis; (2) we adopted a heuristic feature engineer approach to cluster connected devices into different types based on their daily connection duration. We tested the method in an office building located in California. In an area with an average occupancy of 22–27 people and a peak occupancy of 48 - 74 people, the root square mean error on the test set is less than four people. The error is within two people counts for more than 70% of estimations, and less than six counts for more than 90% of estimations, indicating a relatively high accuracy. The major contribution of this study is proposing a novel and accurate approach to detect occupant counts in a non-intrusive way, i.e., utilizing existing Wi-Fi infrastructure in buildings without requiring the installation of extra hardware or sensors. The method we proposed is generic and could be applied to other commercial buildings to infer occupant counts for energy efficient building control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data fusion in predicting internal heat gains for office buildings through a deep learning approach

Heating, Ventilation, and Air Conditioning (HVAC) is a major energy consumer in buildings. The predictive control has demonstrated a potential to reduce HVAC energy use. To facilitate predictive HVAC control, internal heat gains prediction is required. Here, we applied Long Short-Term Memory Networks, a special form of deep neural network, to predict miscellaneous electric loads, lighting loads, occupant counts and internal heat gains in two United States office buildings. Compared with the predetermined schedules used in American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) standard 90.1, the Long Short-Term Memory Networks method could reduce the prediction errors of internal heat gains from 12% to 8% in Building A, and from 26% to 16% in Building B. It was also found that for internal heat gains prediction, miscellaneous electric loads is a more important feature than occupant counts for two reasons. First, miscellaneous electric loads is the best proxy variable for internal heat gains, as it is the major component of and has the highest correlation coefficient with the internal heat gains. Second, miscellaneous electric loads contain valuable information to predict occupant count, while occupant count could not help improve miscellaneous electric loads prediction. Lastly, these findings could help researchers and practitioners select the most relevant features to more accurately predict internal heat gains for the implementation of predictive HVAC control in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zinc Removal from Basic Oxygen Steelmaking Filter Cake by Leaching with Organic Acids

The dust generated from the basic oxygen steelmaking (BOS) process is a waste material mainly containing iron that cannot be recycled owing to its high zinc content. In this study, the leaching effects of different organic acids are compared, with the aim of determining an acid that selectively leaches and removes zinc from BOS dust, so that the waste material can be recycled into ironmaking and steelmaking processes in order to substitute part of the raw materials of steelmaking. The dust used in this study was scrubbed and collected in the form of a filter cake. The acids tested were oxalic, citric, acetic, propionic, butyric, and valeric acids. Butyric acid was found to be the most effective, with a high zinc extraction level of 49.7 pct and a low iron level of only 2.5 pct. Oxalic acid was the least effective leaching reagent for both zinc and iron extractions, owing to the formation of zinc and iron oxalate precipitates following metal dissolution. The filter cake and leached residues were characterized by chemical analysis, X-ray diffraction, X-ray photoelectron spectroscopy, and scanning electron microscopy with energy dispersive spectroscpopy.

36 MATERIALS SCIENCE↗

Slow liquid scintillator candidates for MeV-scale neutrino experiments

Slow liquid scintillator Cherenkov detectors have been proposed as part of several future neutrino experiments because they can provide both directionality and energy measurements. This feature is expected to enhance the sensitivities for MeV-scale neutrino physics, including solar physics, the search for supernova relic neutrino, and the study of geo-sciences. In this study, the characteristics of a slow liquid scintillator were investigated, along with the light yields and decay time constants for various combinations of linear alkylbenzene (LAB), 2,5-diphenyloxazole (PPO), and 1,4-bis (2-methylstyryl)-benzene (bis-MSB). Here, the results of our study indicated that LAB with 0.07 g/L of PPO and 13 mg/L of bis-MSB was the best candidate for an effective separation between Cherenkov and scintillation lights with a reasonably high light yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗