Engineering Papers⌕ Search

Engineering topics

Wang, Ying

Publications and source records attributed to Wang, Ying.

At least 181 records · Page 10

Cadmium-induced neural tube defects and fetal growth restriction: Association with disturbance of placental folate transport

Previous studies found that maternal Cd exposure on gestational day (GD)9 caused forelimb ectrodactyly and tail deformity, the characteristic malformations. The aim of the present study was to investigate whether maternal Cd exposure on GD8 induces fetal neural tube defects (NTDs). Pregnant mice were intraperitoneally injected with CdCl{sub 2} (2.5 or 5.0 mg/kg) on GD8. Neither forelimb ectrodactyly nor tail deformity was observed in mice injected with CdCl{sub 2} on GD8. Instead, maternal Cd exposure on GD8 resulted in the incidence of NTDs. Moreover, maternal Cd exposure on GD8 resulted in fetal growth restriction. In addition, maternal Cd exposure on GD8 reduced placental weight and diameter. The internal space of maternal and fetal blood vessels in the labyrinth layer was decreased in the placentas of mice treated with CdCl{sub 2}. Additional experiment showed that placental PCFT protein and mRNA, a critical folate transporter, was persistently decreased when dams were injected with CdCl{sub 2} on GD8. Correspondingly, embryonic folate content was markedly decreased in mice injected with CdCl{sub 2} on GD8, whereas Cd had little effect on folate content in maternal serum. Taken together, these results suggest that maternal Cd exposure during organogenesis disturbs transport of folate from maternal circulation to the fetuses through down-regulating placental folate transporters. - Highlights: • Maternal Cd exposure during organogenesis causes NTDs and FGR. • Maternal Cd exposure during organogenesis impairs placental development. • Cd disturbs transport of folate by down-regulating placental folate transporters.

60 APPLIED LIFE SCIENCES↗

Broadband microwave characteristics of a novel coaxial gridded hollow cathode argon plasma

The interaction between microwave and large area plasma is crucially important for space communication. Gas pressure, input power, and plasma volume are critical to both the microwave electromagnetic wave phase shift and electron density. This paper presents a novel type of large coaxial gridded hollow cathode plasma having a 50 cm diameter and a 40 cm thickness. Microwave characteristics are studied using a microwave measurement system that includes two broadband antennae in the range from 2 GHz to 18 GHz. The phase shift under varying gas pressure and input power is shown. In addition, the electron density n{sub e}, which varies from 1.2 × 10{sup 16} m{sup −3} to 8.7 × 10{sup 16} m{sup −3} under different discharge conditions, is diagnosed by the microwave system. The measured results accord well with those acquired by Langmuir Probe measurement and show that the microwave properties in the large volume hollow cathode discharge significantly depend on the input power and gas pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The method of impedance transformation for electromagnetic waves propagating in one-dimension plasma photonic crystal

This study focuses on the transmission of normal-incidence electromagnetic waves in one-dimensional plasma photonic crystals. Using the Maxwell's equations in a medium, a method that is based on the concept of impendence is employed to perform the simulation. The accuracy of the method was evaluated by simulating a one-layer plasma and conventional photonic crystal. In frequency-domain, the transmission and reflection coefficients in the unmagnetized plasma photonic crystal were calculated, and the influence factors on plasma photonic crystals including dielectric constants of dielectric, spatial period, filling factor, plasma frequency, and collision frequency were studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute continuum intensity diagnostics of a novel large coaxial gridded hollow cathode argon plasma

This paper reports a novel coaxial gridded hollow discharge during operation at low pressure (20 Pa–80 Pa) in an argon atmosphere. A homogeneous hollow discharge was observed under different conditions, and the excitation mechanism and the discharge parameters for the hollow cathode plasma were examined at length. An optical emission spectrometry (OES) method, with a special focus on absolute continuum intensity method, was employed to measure the plasma parameters. The Langmuir probe measurement (LPM) was used to verify the OES results. Both provided electron density values (n{sub e}) in the order of 10{sup 16} m{sup −3} for different plasma settings. Taken together, the results show that the OES method is an effective approach to diagnosing the similar plasma, especially when the LPM is hardly operated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transmission characteristics of microwave in a glow-discharge dusty plasma

In this study, the propagation characteristics of electromagnetic wave in a glow discharge plasma with dust particles are experimentally investigated. A helium alternating current glow discharge plasmas have been successfully generated. Measurements of the plasma parameters using Langmuir probes, in the absence of dust particles, provide plasma densities (n{sub e}) of 10{sup 17 }m{sup −3} and electron temperatures (T{sub e}) ranging from 2 to 4 eV. Dusty plasmas are made by adding 30 nm radius aluminum oxide (Al{sub 2}O{sub 3}) particles into the helium plasma. The density of the dust particle (n{sub d}) in the device is about 10{sup 11}–10{sup 12 }m{sup −3}. The propagation characteristics of electromagnetic waves are determined by a vector network analyzer with 4–6 GHz antennas. An apparent attenuation by the dust is observed, and the measured attenuation data are approximately in accordance with the theoretical calculations. The effects of gas pressure and input power on the propagation are also investigated. Results show that the transmission attenuation increases with the gas pressure and input power, the charged dust particles play a significant role in the microwave attenuation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interfractional variation in bladder volume and its impact on cervical cancer radiotherapy: Clinical significance of portable bladder scanner

Purpose: A constant bladder volume (BV) is essential to direct the radiotherapy (RT) of pelvic tumors with precision. The purpose of this study was to investigate changes in BV and their impact on cervical cancer RT and to assess the clinical significance of a portable bladder scanner (BS) in achieving a constant BV. Methods: A standard bladder phantom (133 ml) and measurements of actual urine volume were both used as benchmarks to evaluate the accuracy of the BS. Comparisons of BS with computed tomography (CT), cone-beam CT (CBCT), and an ultrasound diagnostic device (iU22) were made. Twenty-two consecutive patients with cervical cancer treated with external beam radical RT were divided into an experimental group (13 patients) and a control group (9 patients). In the experimental group, the BV was measured multiple times by BS pre-RT until it was consistent with that found by planning CT. Then a CBCT was performed. The BV was measured again immediately post-RT, after which the patient’s urine was collected and recorded. In the control group, CBCT only was performed pre-RT. Interfractional changes in BV and their impact on cervical cancer RT were investigated in both groups. The time of bladder filling was also recorded and analyzed. Results: In measuring the volume of the standard bladder phantom, the BS deviated by 1.4% in accuracy. The difference between the measurements of the BS and the iU22 had no statistical significance (linear correlation coefficient 0.96, P < 0.05). The BV measured by the BS was strongly correlated with the actual urine volume (R = 0.95, P < 0.05), planning CT (R = 0.95, P < 0.05), or CBCT (R = 0.91, P < 0.05). Compared with the BV at the time of CT, its value changed by −36.1% [1 SD (standard deviation) 42.3%; range, −79.1%–29.4%] in the control group, and 5.2% (1 SD 21.5%; range, −13.3%–22.1%) in the experimental group during treatment. The change in BV affected the target position in the superior–inferior (SI) direction but had little or no effect in the anterior–posterior and right–left directions. Based on the collected data, the target displacement in the SI direction was reduced from 2.0 to 0.4 mm, while the CTV-to-PTV (CTV: clinical target volume; PTV: planning target volume) margin in the SI direction was reduced from 11.1 to 6.4 mm. The BV increased by 3.7 ± 1.0 ml/min (range, 1.7–4.7 ml/min), which depended on the amount of water ingested by the patient (R = 0.96, P < 0.05). No correlation was found between the rate of urinary inflow and the patient’s body mass. The authors were able to reduce the workload of measuring by using individual patient information including the patient’s age, the water-drinking amount, time at which water-drinking began, and patient’s diet. Conclusions: Changes in the BV have an influence on the RT of cervical cancer. A consistent and reproducible BV is acquired by using a portable BS, whereby the target displacement and CTV-to-PTV margin can be both reduced in the SI direction.

60 APPLIED LIFE SCIENCES↗

Enhancement of the performance of GaN IMPATT diodes by negative differential mobility

A theoretical analysis of high-efficiency punch-through operation GaN-based terahertz IMPATT diodes has been carried out in this paper. It is shown that the negative differential mobility (NDM) characteristics of GaN coupled with the space charge effect acting as a self-feedback system can markedly increase the drift velocity of injection carriers, and thereby enhance diode performance under appropriate external RF voltage. The behavior of traveling electrons in the transit zone is investigated in detail. It is found that the IMPATT diode with a punch-through structure operating in the NDM mode exhibits superior characteristics compared with the equivalent diode operating in the Si-like constant mobility mode. In particular, the NDM-mode diode can tolerate a larger RF voltage swing than that operating in constant mobility mode. Numerical simulation results reveal that the highest efficiency of 26.6% and maximum RF power of 2.29 W can be achieved for the NDM-mode diode at a frequency of 225 GHz. A highest efficiency of 19.0% and maximum RF power of 1.58 W are obtained for the diode with constant mobility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of Assay Type in Determining Free 25-Hydroxyvitamin D Levels in Diverse Populations

Serum 25-hydroxyvitamin D (25OHD) is the most frequently used marker of vitamin D status. Low 25OHD is associated with bone loss, fractures {Cauley, 2010 #1516;Ensrud, 2009 #1517}, and other adverse health outcomes {Theodoratou, 2014 #1518}. Most extra renal tissues only have access to free 25OHD, and free 25OHD concentration is thus a plausible biomarker of 25OHD availability and function {Johnsen, 2014 #1443;Chun, 2014 #1343}. Stronger associations with free or bioavailable 25OHD than with total 25OHD were reported for serum calcium, parathyroid hormone (PTH) {Bhan, 2012 #1124} and bone mineral density (BMD) {Powe, 2011 #1129}. These findings have led to the suggestion that free or bioavailable 25OHD may provide a more clinically relevant measure of tissue 25OHD availability and vitamin D status {Powe, 2013 #1369; Holick NEJM 2013 editorial}. The US Preventive Services Task Force (LeFevre 2015) recently pointed to the gap in research regarding bioavailable and free 25OHD and noted the possibility that these may be better markers of tissue 25OHD availability. Free 25OHD is conventionally calculated from the concentrations of total 25OHD, vitamin D binding protein (DBP) and albumin, with or without a factor accounting for DBP genotype-specific binding affinities {Bouillon, 1981 #1207;Chun, 2012 #1143; Powe, 2011 #1129;Johnsen, 2014 #1443}. DBP—or Group specific component (GC) {Hirschfeld, 1959 #1468}—polymorphisms (rs4588 and rs7041) give rise to three major polymorphic isoforms of DBP, GC-1F, GC-1S and GC-2, the frequencies of which differ globally, with GC-1F alleles more common in populations of African descent {Kambou, 1986 #1122}. Although DBP is a primary component of free and bioavailable 25OHD calculations, substantial variation in DBP between assays has been noted (Powe suggest to cite here previous publications as in previous version of this Ms). Using DBP measured by a monoclonal antibody Powe et al. {Powe, 2013 #1369} concluded that calculated free 25OHD in African-Americans was equal or higher than in US whites, questioning the implications of low total 25OHD concentrations in African Americans (Holick 2013). This idea gained widespread attention in medical and lay press {LeFevre, 2015 #1598; Bhan, 2014 #1485; Durazo-Arvizu, 2014 #1519}, and many others) and may have important implications for nutrional supplementation policy. To better understand the importance of free 25OHD estimates, and its racial differences, we conducted studies in cohorts based in the US, UK and The Gambia that included participants of African and European ancestry known to differ in GC genotype distribution. We characterized the molecular forms of circulating DBP through comparison of several DBP assays and DBP peptide proteomic analysis, to obtain both calculated and directly measured free 25OHD by geographical region, race and GC genotype.

Environmental Molecular Sciences Laboratory↗

Asymmetric quantum-well structures for AlGaN/GaN/AlGaN resonant tunneling diodes

Asymmetric quantum-well (QW) structures including the asymmetric potential-barrier and the asymmetric potential-well are proposed for AlGaN/GaN/AlGaN resonant tunneling diodes (RTDs). Theoretical investigation gives that an appropriate decrease in Al composition and thickness for emitter barrier as well as an appropriate increase of both for collector barrier can evidently improve the negative-differential-resistance characteristic of RTD. Numerical simulation shows that RTD with a 1.5-nm-thick GaN well sandwiched by a 1.3-nm-thick Al{sub 0.15}Ga{sub 0.85}N emitter barrier and a 1.7-nm-thick Al{sub 0.25}Ga{sub 0.75}N collector barrier can yield the I-V characteristic having the peak current (Ip) and the peak-to-valley current ratio (PVCR) of 0.39 A and 3.6, respectively, about double that of RTD with a 1.5-nm-thick Al{sub 0.2}Ga{sub 0.8}N for both barriers. It is also found that an introduction of InGaN sub-QW into the diode can change the tunneling mode and achieve higher transmission coefficient of electron. The simulation demonstrates that RTD with a 2.8-nm-thick In{sub 0.03}Ga{sub 0.97}N sub-well in front of a 2.0-nm-thick GaN main-well can exhibit the I-V characteristic having Ip and PVCR of 0.07 A and 11.6, about 7 times and double the value of RTD without sub-QW, respectively. The purpose of improving the structure of GaN-based QW is to solve apparent contradiction between the device structure and the device manufacturability of new generation RTDs for sub-millimeter and terahertz applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin-orbit torque induced magnetization switching in Ta/Co{sub 20}Fe{sub 60}B{sub 20}/MgO structures under small in-plane magnetic fields

Spin-orbit torque (SOT)-induced magnetization switching under small in-plane magnetic fields in as-deposited and annealed Ta/CoFeB/MgO structures is studied. For the as-deposited samples, partial SOT-induced switching behavior is observed under an in-plane field of less than 100 Oe. Conversely, for the annealed samples, an in-plane field of 10 Oe is large enough to achieve full deterministic magnetization switching. The Dzyaloshinskii-Moriya interaction at the Ta/CoFeB interface is believed to be the main reason for the discrepancy of the requisite in-plane magnetic fields for switching in the as-deposited and annealed samples. In addition, asymmetric field dependence behavior of SOT-induced magnetization switching is observed in the annealed samples. Deterministic magnetization switching in the absence of an external magnetic field is obtained in the annealed samples, which is extremely important to develop SOT-based magnetoresistive random access memory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface defect passivation of MoS{sub 2} by sulfur, selenium, and tellurium

Few-layer MoS{sub 2} field-effect transistors often show an n-type conduction behavior due to the presence of high-density sulfur vacancies. Here, we investigated the possibility of surface defect passivation of MoS{sub 2} by sulfur treatment in (NH{sub 4}){sub 2}S solution or coating with an ultrathin layer of selenium or tellurium. It was found that all three elements investigated are able to induce a p-doping effect through suppressing the residual electron concentration by an amount exceeding 0.5 × 10{sup 12 }cm{sup −2} in few-layer MoS{sub 2}. Among them, the sulfur-treatment exhibits the most superior thermal stability that survives thermal annealing at temperatures ≥120 °C for at least 10 h. Tellurium exhibits the strongest p-doping effect due to electron trapping by physisorption-induced gap states near the valence band edge. On the other hand, selenium is highly volatile on MoS{sub 2}; it evaporates and desorbs easily due to Joule heating during electrical measurements in vacuum. The results of first-principles calculations support the experimental observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Propagation of electromagnetic waves in a weak collisional and fully ionized dusty plasma

The propagation properties of electromagnetic (EM) waves in fully ionized dusty plasmas is the subject of this study. The dielectric relationships for EM waves propagating in a fully ionized dusty plasma was derived from the Boltzmann distribution law, taking into consideration the collision and charging effects of the dust grains. The propagation properties of the EM waves in a dusty plasma were numerically calculated and studied. The study results indicated that the dusty grains with an increased radius and charge were more likely to impede the penetration of EM waves. Dust grains with large radii and high charge cause the attenuation of the EM wave in the dusty plasma. The different density of the dust in the plasma appeared to have no obvious effect on the transmission of the EM waves. The propagation of the EM waves in a weakly ionized dusty plasma varies from that in a fully ionized dusty plasma. The results are helpful to analyze the effects of dust in dusty plasmas and also provide a theoretical basis for future studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparison of volumetric modulated arc therapy and sliding-window intensity-modulated radiotherapy in the treatment of Stage I-II nasal natural killer/T-cell lymphoma

This article is aimed to compare the dosimetric differences between volumetric modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) for Stage I-II nasal natural killer/T-cell lymphoma (NNKTL). Ten patients with Stage I-II NNKTL treated with IMRT were replanned with VMAT (2 arcs). The prescribed dose of the planning target volume (PTV) was 50 Gy in 25 fractions. The VMAT plans with the Anisotropic Analytical Algorithm (Version 8.6.15) were based on an Eclipse treatment planning system; the monitor units (MUs) and treatment time (T) were scored to measure the expected treatment efficiency. All the 10 patients under the study were subject to comparisons regarding the quality of target coverage, the efficiency of delivery, and the exposure of normal adjacent organs at risk (OARs). The study shows that VMAT was associated with a better conformal index (CI) and homogeneity index (HI) (both p < 0.05) but slightly higher dose to OARs than IMRT. The MUs with VMAT (650.80 ± 24.59) were fewer than with IMRT (1300.10 ± 57.12) (relative reduction of 49.94%, p = 0.00) when using 2-Gy dose fractions. The treatment time with VMAT (3.20 ± 0.02 minutes) was shorter than with IMRT (7.38 ± 0.18 minutes) (relative reduction of 56.64%, p = 0.00). We found that VMAT and IMRT both provide satisfactory target dosimetric coverage and OARs sparing clinically. Likely to deliver a bit higher dose to OARs, VMAT in comparison with IMRT, is still a better choice for treatment of patients with Stage I-II NNKTL, thanks to better dose distribution, fewer MUs, and shorter delivery time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Chemisorption-induced n-doping of MoS{sub 2} by oxygen

Both chemisorption and physisorption affect the electronic properties of two-dimensional materials, such as MoS{sub 2}, but it remains a challenge to probe their respective roles experimentally. Through repeated in-situ electrical measurements of few-layer MoS{sub 2} field-effect transistors in an ultrahigh vacuum system with well-controlled oxygen partial pressure (6 × 10{sup −8} mbar–3 × 10{sup −7} mbar), we were able to study the effect of chemisorption on surface defects separately from physically adsorbed oxygen molecules. It is found that chemisorption of oxygen results in n-doping in the channel but negligible effect on mobility and on/off ratio of the MoS{sub 2} transistors. These results are in disagreement with the previous reports on p-doping and degradation of the device's performance when both chemisorption and physisorption are present. Through the analysis of adsorption-desorption kinetics and the first-principles calculations of electronic properties, we show that the experimentally observed n-doping effect originates from dissociative adsorption of oxygen at the surface defects of MoS{sub 2}, which lowers the conduction band edge locally and makes the MoS{sub 2} channel more n-type-like as compared to the as-fabricated devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TLR4/MD-2 activation by a synthetic agonist with no similarity to LPS

Structurally disparate molecules reportedly engage and activate Toll-like receptor (TLR) 4 and other TLRs, yet the interactions that mediate binding and activation by dissimilar ligands remain unknown. We describe Neoseptins, chemically synthesized peptidomimetics that bear no structural similarity to the established TLR4 ligand, lipopolysaccharide (LPS), but productively engage the mouse TLR4 (mTLR4)/myeloid differentiation factor 2 (MD-2) complex. Neoseptin-3 activates mTLR4/MD-2 independently of CD14 and triggers canonical myeloid differentiation primary response gene 88 (MyD88)- and Toll-interleukin 1 receptor (TIR) domain-containing adaptor inducing IFN-beta (TRIF)-dependent signaling. The crystal structure mTLR4/MD-2/Neoseptin-3 at 2.57-Å resolution reveals that Neoseptin-3 binds as an asymmetrical dimer within the hydrophobic pocket of MD-2, inducing an active receptor complex similar to that induced by lipid A. Furthermore, Neoseptin-3 and lipid A form dissimilar molecular contacts to achieve receptor activation; hence strong TLR4/MD-2 agonists need not mimic LPS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗