Sodiation via Heterogeneous Disproportionation in FeF2 Electrodes for Sodium-Ion Batteries
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Wang, Liping.
Explore the source record for details and available documents.
This paper presents a new model to simulate energy performance of variable refrigerant flow (VRF) systems in heat pump operation mode (either cooling or heating is provided but not simultaneously). The main improvement of the new model is the introduction of the evaporating and condensing temperature in the indoor and outdoor unit capacity modifier functions. The independent variables in the capacity modifier functions of the existing VRF model in EnergyPlus are mainly room wet-bulb temperature and outdoor dry-bulb temperature in cooling mode and room dry-bulb temperature and outdoor wet-bulb temperature in heating mode. The new approach allows compliance with different specifications of each indoor unit so that the modeling accuracy is improved. The new VRF model was implemented in a custom version of EnergyPlus 7.2. This paper first describes the algorithm for the new VRF model, which is then used to simulate the energy performance of a VRF system in a Prototype House in California that complies with the requirements of Title 24 ? the California Building Energy Efficiency Standards. The VRF system performance is then compared with three other types of HVAC systems: the Title 24-2005 Baseline system, the traditional High Efficiency system, and the EnergyStar Heat Pump system in three typical California climates: Sunnyvale, Pasadena and Fresno. Calculated energy savings from the VRF systems are significant. The HVAC site energy savings range from 51 to 85percent, while the TDV (Time Dependent Valuation) energy savings range from 31 to 66percent compared to the Title 24 Baseline Systems across the three climates. The largest energy savings are in Fresno climate followed by Sunnyvale and Pasadena. The paper discusses various characteristics of the VRF systems contributing to the energy savings. It should be noted that these savings are calculated using the Title 24 prototype House D under standard operating conditions. Actual performance of the VRF systems for real houses under real operating conditions will vary.
Hepatocyte growth factor activator inhibitor type 2 (SPINT2), a Kunitz-type serine proteinase inhibitor, has been identified as a putative tumor suppressor gene silenced by promoter methylation. We aimed to investigate whether SPINT2 might act as an esophageal squamous cell carcinoma (ESCC) tumor suppressor gene. Four ESCC cell lines, Fifty-two ESCC tissues and twenty-nine neighboring non-cancerous tissues were included in this study. The expression of SPINT2 was monitored by real time PCR. Bisulfite genomic sequencing and methylation-specific PCR were used to analyze methylation status. The effect of SPINT2 on cell proliferation and apoptosis in EC109 and EC9706 cells was observed by CCK-8 assay and flow cytometric analysis. We found that silencing of SPINT2 was associated with promoter methylation in ESCC cell lines. The densely methylated SPINT2 promoter region was confirmed by bisulfite genomic sequencing. Ectopic expression of SPINT2 inhibited cell proliferation through inducing cell apoptosis in vitro. Furthermore, methylation-specific PCR analysis revealed that SPINT2 promoter methylation was prominent in carcinoma tissues (52.08%) compared with neighboring non-cancerous tissues (22.58%). Kaplan–Meier analysis showed that patients with SPINT2 hypermethylation had shorter survival time. The tumor suppressor gene of SPINT2 is commonly silenced by promoter hypermethylation in human ESCC and SPINT2 hypermethylation is correlated with poor overall survival, implicating SPINT2 is an underlying prognostic marker for human ESCC. - Highlights: • We firstly found SPINT2 gene may be transcriptionally repressed by promoter hypermethylation in ESCC cells. • SPINT2 overexpressing cells induced proliferation inhibition through promoting apoptosis. • mRNA expression of SPINT2 was significantly higher in ESCC tissues than in neighboring non-cancerous tissues. • Promoter hypermethylation of SPINT2 is significantly linked to TNM stage and poor overall survival.
This software package is the Graphic User Interface (GUI) software component for the Sensor Suitcase Retro-Commissioning project, which is a sensor and analysis system to support monitoring-based retro-commissioning of small commercial buildings, performed by non-experts. Small commercial buildings typically do not have the budgets or business economics to allow investing in energy efficiency enhancements the building retro-commissioning provides. In addition, they do not have in-house staff with expertise in building systems who can perform building retro-commissioning or identify energy efficiency improvement opportunities. The solution to this problem is to develop a turn-key hardware/software solution (the RCx Sensor Suitcase) that can be used by non-experts to automatically generate low and no-cost energy efficiency rec commendations that will improve building operating costs, occupant comfort and building energy performance. This is a joint project between Lawrence Berkeley National Laboratory, leading the development of the software and analysis elements, and Pacific Northwest National Laboratory (PNNL), leading the development of the hardware and sensor elements with an associated table-based configuration support tool. The project is funded by the U.S. Department of Energy. This software package was developed as a proof-of-concept prototype for the sensor suitcase software component. The software component was developed with a Microsoft Excel spreadsheet which reads the sensor data and calls a MATLAB DLL to analyze the sensor data.
We conducted in-situ high-pressure synchrotron x-ray experiments on beryllium metal at pressures up to 7.9 GPa and temperatures up to 1373 K. A complete pressure (P)–volume (V)–temperature (T) equation of state (EOS) is determined based on the experiment, which includes temperature derivatives of elastic bulk modulus (at both constant pressure and constant volume) and pressure dependence of thermal expansivity. From this EOS, we calculate thermal pressure, heat capacity at constant volume, and thermodynamic Grüneisen parameter as a function of temperature. Above ∼600 K, our results show notable deviation from theoretical predictions using the quasiharmonic and local-density approximations, indicating that the free energy calculations need to be further improved within the current scheme of approximations.
Abstract not provided
Explore the source record for details and available documents.
Almost half of the total energy used in the U.S. buildings is consumed by heating, ventilation and air conditionings (HVAC) according to EIA statistics. Among various driving factors to energy performance of building, operations and maintenance play a significant role. Many researches have been done to look at design efficiencies and operational controls for improving energy performance of buildings, but very few study the impacts of HVAC systems maintenance. Different practices of HVAC system maintenance can result in substantial differences in building energy use. If a piece of HVAC equipment is not well maintained, its performance will degrade. If sensors used for control purpose are not calibrated, not only building energy usage could be dramatically increased, but also mechanical systems may not be able to satisfy indoor thermal comfort. Properly maintained HVAC systems can operate efficiently, improve occupant comfort, and prolong equipment service life. In the paper, maintenance practices for HVAC systems are presented based on literature reviews and discussions with HVAC engineers, building operators, facility managers, and commissioning agents. We categorize the maintenance practices into three levels depending on the maintenance effort and coverage: 1) proactive, performance-monitored maintenance; 2) preventive, scheduled maintenance; and 3) reactive, unplanned or no maintenance. A sampled list of maintenance issues, including cooling tower fouling, boiler/chiller fouling, refrigerant over or under charge, temperature sensor offset, outdoor air damper leakage, outdoor air screen blockage, outdoor air damper stuck at fully open position, and dirty filters are investigated in this study using field survey data and detailed simulation models. The energy impacts of both individual maintenance issue and combined scenarios for an office building with central VAV systems and central plant were evaluated by EnergyPlus simulations using three approaches: 1) direct modeling with EnergyPlus, 2) using the energy management system feature of EnergyPlus, and 3) modifying EnergyPlus source code. The results demonstrated the importance of maintenance for HVAC systems on energy performance of buildings. The research is intended to provide a guideline to help practitioners and building operators to gain the knowledge of maintaining HVAC systems in efficient operations, and prioritize HVAC maintenance work plan. The paper also discusses challenges of modeling building maintenance issues using energy simulation programs.
Constitutive laws and crystal plasticity in diamond deformation have been the subjects of substantial interest since synthetic diamond was made in 1950's. To date, however, little is known quantitatively regarding its brittle-ductile properties and yield strength at high temperatures. In this paper, we report, for the first time, the strain-stress constitutive relations and experimental demonstration of deformation mechanisms under confined high pressure. The deformation at room temperature is essentially brittle, cataclastic, and mostly accommodated by fracturing on {111} plane with no plastic yielding at uniaxial strains up to 15%. At elevated temperatures of 1000°C and 1200°C diamond crystals exhibit significant ductile flow with corresponding yield strength of 7.9 and 6.3 GPa, indicating that diamond starts to weaken when temperature is over 1000°C. Finally, at high temperature the plastic deformation and ductile flow is meditated by the <110>{111} dislocation glide and a very active {111} micro-twinning.
Abstract not provided
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Commercial mortgage contracts currently do not fully account for the risks inherent in the level and volatility of energy use in commercial buildings. As a result, energy efficiency is not explicitly included in the valuation process for commercial mortgage underwriting. In particular, there is limited if any consideration of the volatility of energy use and price, which is critical to evaluate the impact of extreme events and default risk. Explicit inclusion of energy use and volatility in commercial mortgage underwriting can send a strong “price signal” that financially rewards and values energy efficiency in commercial properties. This report presents the results of a technical analysis of and a proposed protocol to assess energy use volatility for the purposes of commercial mortgage valuation.
Compressional and shear wave velocities of Zr{sub 46}Cu{sub 37.6}Ag{sub 8.4}Al{sub 8} bulk metallic glass (BMG) have been measured up to 6.3 GPa at room temperature using ultrasonic interferometry in conjunction with synchrotron X-radiography. The densities at high pressures are uniquely determined using the measured velocities. The experimental results for the elastic moduli of Zr{sub 46}Cu{sub 37.6}Ag{sub 8.4}Al{sub 8} show a reasonable agreement with the Voigt-Reuss-Hill approximation of the element metal phases, indicating that the elastic properties of the BMG have a close correlation with its constituent components.
Explore the source record for details and available documents.