Engineering Papers⌕ Search

Engineering topics

Wang, Ge

Publications and source records attributed to Wang, Ge.

The United States Department of Energy and National Institutes of Health Collaboration: Medical Care Advances by Discovery in Radiation Detection

A National Institutes of Health (NIH) and U.S. Department of Energy (DOE) Office of Science virtual workshop on shared general topics was held in July of 2021 and reported on in this publication in January of 2023. Following the inaugural 2021 joint meeting representatives from the DOE Office of Science and NIH met to discuss organizing a second joint workshop that would concentrate on radiation detection to bring together teams from both agencies and their grantee populations to stimulate collaboration and efficiency. To meet this scientific mission within the NIH and DOE radiation detection space, the organizers assembled workshop sessions covering the state–of–the–art in cameras, detectors, and sensors for radiation external and internal (diagnostic and therapeutic) to human, data acquisition and electronics, image reconstruction and processing, and the application of artificial intelligence. NIH and DOE are committed to continuing the process of convening a joint workshop every 12–24 months. This Special Report recaps the findings of this second workshop. Beyond showing only the innovations and areas of success, important gaps in our knowledge were defined and presented. Finally, we summarize by defining four areas of greatest opportunity and need that emerged from the unique, dynamic dialogue the in–person workshop provided the attendees.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tunable phase structure in NaNbO 3 ceramics by grain-size effect, electric field and heat treatment

Large polarization and strain change during antiferroelectric - ferroelectric phase transition under electric field is the foundation for realizing excellent electrical properties in antiferroelectric ceramics, therefore, the adjustment of antiferroelectricity and clarification of the corresponding mechanism is the foundation for controlling electrical properties. NaNbO3 is the most complex perovskite system showing multiple antiferroelectric phases in a wide temperature range, in which the antiferroelectricity shows obvious instability with changing external and internal conditions, namely the antiferroelectric phase can be adjusted by grain-size effect, electric field and heat treatment. According to the systematical study in terms of the Rietveld refinement of synchrotron XRD and Raman, NaNbO3 exhibits a ferrielectric P21ma structure at room temperature, the ferroelectric component of which increases with decreasing grain size. Two antiferroelectric tetragonal phases exist around Curie temperature TC before the entrance of antiferroelectric R phase zone, while an antiferroelectric monoclinic phase, which can be maintained to room temperature by annealing treatment, acts as the bridge for the depolarization of the poled NaNbO3 with ferroelectric Q phase. A detailed phase diagram mainly focused on the antiferroelectric phase zones of NaNbO3 is plotted, which gives a clear understanding about the polymorphic phase transitions under different conditions. Finally, the results concluded in this work would give a clear guidance for designing high-performance NaNbO3-based lead-free ceramics from the point of structure.

36 MATERIALS SCIENCE↗

Workability of High-Strength Automobile Steel at High Temperatures Using Hot Processing Maps and Electron Backscatter Diffraction

Hot deformation behavior of a high-strength steel Docol 1500 Bor was investigated by compression tests on a thermal–mechanical simulator Gleeble 3500. The workability of tested steel was analyzed by building processing maps at three strains based on the test results of flow stresses. The essential deformation mechanism was further studied based on the deformation texture analysis on a scanning electronic microscope with a TSL-OIM™EBSD system. It was found that that strain can affect the workability of the tested steel remarkably. At the engineering strain of 0.6, obvious textures in martensite mainly include recrystallization textures <110>//ND and other texture components <110>//RD and {001} <100>, etc. Dynamic recrystallization and recrystallization texture component <111>//ND in deformed austenite can contribute to increasing the workability of a steel Docol 1500 Bor. Finally, the optimized deformation conditions of the tested steel were obtained.

36 MATERIALS SCIENCE↗

Self–Destruction of Cancer Induced by Ag 2 S Amorphous Nanodots

Studies on distinctive performances and novel applications of amorphous inorganic nanomaterials are becoming attractive. Herein, Ag 2 S amorphous and crystalline nanodots (ANDs and CNDs) are prepared via facile methods. In vitro and in vivo studies indicate that Ag 2 S ANDs, rather than CNDs, can induce the self-destruction of tumors, which can be attributed to their distinctive chemical properties, e.g., the higher electrochemical active surface area and lower redox potential well matching with the redox reaction requirement in the tumor microenvironment. Ag 2 S ANDs can be oxidized by intracellular reactive oxygen species (ROS) to release Ag + , which further stimulates high generation of intracellular ROS. This mutual stimulation damages the mitochondria, induces apoptosis, and leads to the self-destruction of the tumor. Moreover, Ag 2 S ANDs do not show observable in vitro and in vivo side effects. Furthermore, these findings provide a promising self-destructive strategy for cancer therapy by utilizing distinctive chemical properties of inorganic nanomaterials, while avoiding complicated external assistance.

60 APPLIED LIFE SCIENCES↗

High-quality mesoporous graphene particles as high-energy and fast-charging anodes for lithium-ion batteries

The application of graphene for electrochemical energy storage has received tremendous attention; however, challenges remain in synthesis and other aspects. Here we report the synthesis of high-quality, nitrogen-doped, mesoporous graphene particles through chemical vapor deposition with magnesium-oxide particles as the catalyst and template. Such particles possess excellent structural and electrochemical stability, electronic and ionic conductivity, enabling their use as high-performance anodes with high reversible capacity, outstanding rate performance (e.g., 1,138 mA h g -1 at 0.2 C or 440 mA h g -1 at 60 C with a mass loading of 1 mg cm -2 ), and excellent cycling stability (e.g., >99% capacity retention for 500 cycles at 2 C with a mass loading of 1 mg cm -2 ). Interestingly, thick electrodes could be fabricated with high areal capacity and current density (e.g., 6.1 mA h cm -2 at 0.9 mA cm -2 ), providing an intriguing class of materials for lithium-ion batteries with high energy and power performance.

25 ENERGY STORAGE↗

Spherical grating based x-ray Talbot interferometry

Purpose: Grating interferometry is a state-of-the-art x-ray imaging approach, which can acquire information on x-ray attenuation, phase shift, and small-angle scattering simultaneously. Phase-contrast imaging and dark-field imaging are very sensitive to microstructural variation and offers superior contrast resolution for biological soft tissues. However, a common x-ray tube is a point-like source. As a result, the popular planar grating imaging configuration seriously restricts the flux of photons and decreases the visibility of signals, yielding a limited field of view. The purpose of this study is to extend the planar x-ray grating imaging theory and methods to a spherical grating scheme for a wider range of preclinical and clinical applications. Methods: A spherical grating matches the wave front of a point x-ray source very well, allowing the perpendicular incidence of x-rays on the grating to achieve a higher visibility over a larger field of view than the planer grating counterpart. A theoretical analysis of the Talbot effect for spherical grating imaging is proposed to establish a basic foundation for x-ray spherical gratings interferometry. An efficient method of spherical grating imaging is also presented to extract attenuation, differential phase, and dark-field images in the x-ray spherical grating interferometer. Results: Talbot self-imaging with spherical gratings is analyzed based on the Rayleigh–Sommerfeld diffraction formula, featuring a periodic angular distribution in a polar coordinate system. The Talbot distance is derived to reveal the Talbot self-imaging pattern. Numerical simulation results show the self-imaging phenomenon of a spherical grating interferometer, which is in agreement with the theoretical prediction. Conclusions: X-ray Talbot interferometry with spherical gratings has a significant practical promise. Relative to planar grating imaging, spherical grating based x-ray Talbot interferometry has a larger field of view and improves both signal visibility and dose utilization for pre-clinical and clinical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vision 20/20: Simultaneous CT-MRI — Next chapter of multimodality imaging

Multimodality imaging systems such as positron emission tomography-computed tomography (PET-CT) and MRI-PET are widely available, but a simultaneous CT-MRI instrument has not been developed. Synergies between independent modalities, e.g., CT, MRI, and PET/SPECT can be realized with image registration, but such postprocessing suffers from registration errors that can be avoided with synchronized data acquisition. The clinical potential of simultaneous CT-MRI is significant, especially in cardiovascular and oncologic applications where studies of the vulnerable plaque, response to cancer therapy, and kinetic and dynamic mechanisms of targeted agents are limited by current imaging technologies. The rationale, feasibility, and realization of simultaneous CT-MRI are described in this perspective paper. The enabling technologies include interior tomography, unique gantry designs, open magnet and RF sequences, and source and detector adaptation. Based on the experience with PET-CT, PET-MRI, and MRI-LINAC instrumentation where hardware innovation and performance optimization were instrumental to construct commercial systems, the authors provide top-level concepts for simultaneous CT-MRI to meet clinical requirements and new challenges. Simultaneous CT-MRI fills a major gap of modality coupling and represents a key step toward the so-called “omnitomography” defined as the integration of all relevant imaging modalities for systems biology and precision medicine.

60 APPLIED LIFE SCIENCES↗

Modification of Helicobacter pylori peptidoglycan enhances NOD1 activation and promotes cancer of the stomach

Helicobacter pylori is the strongest known risk factor for gastric carcinogenesis. One cancer-linked locus is the cag pathogenicity island, which translocates components of peptidoglycan (PGN) into host cells. NOD1 is an intracellular immune receptor that senses PGN from Gram-negative bacteria and responds by inducing autophagy and activating NF-κB, leading to inflammation-mediated bacterial clearance; however chronic pathogens can evade NOD1-mediated clearance by altering PGN structure. We previously demonstrated that the H. pylori cag + strain 7.13 rapidly induces gastric cancer in Mongolian gerbils. Using 2D-DIGE and mass spectrometry, we identified a novel mutation within the gene encoding the peptidoglycan deacetylase PgdA; therefore, we sought to define the role of H. pylori PgdA in NOD1-dependent activation of NF-κB, inflammation, and cancer. Co-culture of H. pylori strain 7.13 or its pgdA $-$ isogenic mutant with AGS gastric epithelial cells or HEK293 epithelial cells expressing a NF-κB reporter revealed that pgdA inactivation significantly decreased NOD1-dependent NF-κB activation and autophagy. Infection of Mongolian gerbils with an H. pylori pgdA $-$ mutant strain led to significantly decreased levels of inflammation and malignant lesions in the stomach; however, pre-activation of NOD1 prior to bacterial challenge reciprocally suppressed inflammation and cancer in response to wild-type H. pylori . Expression of NOD1 differs in human gastric cancer specimens compared to non-cancer samples harvested from the same patients. In conclusion, these results indicate that PGN deacetylation plays an important role in modulating host inflammatory responses to H. pylori , allowing the bacteria to persist and induce carcinogenic consequences in the gastric niche.

59 BASIC BIOLOGICAL SCIENCES↗

Interior micro-CT with an offset detector

Purpose: The size of field-of-view (FOV) of a microcomputed tomography (CT) system can be increased by offsetting the detector. The increased FOV is beneficial in many applications. All prior investigations, however, have been focused to the case in which the increased FOV after offset-detector acquisition can cover the transaxial extent of an object fully. Here, the authors studied a new problem where the FOV of a micro-CT system, although increased after offset-detector acquisition, still covers an interior region-of-interest (ROI) within the object. Methods: An interior-ROI-oriented micro-CT scan with an offset detector poses a difficult reconstruction problem, which is caused by both detector offset and projection truncation. Using the projection completion techniques, the authors first extended three previous reconstruction methods from offset-detector micro-CT to offset-detector interior micro-CT. The authors then proposed a novel method which combines two of the extended methods using a frequency split technique. The authors tested the four methods with phantom simulations at 9.4%, 18.8%, 28.2%, and 37.6% detector offset. The authors also applied these methods to physical phantom datasets acquired at the same amounts of detector offset from a customized micro-CT system. Results: When the detector offset was small, all reconstruction methods showed good image quality. At large detector offset, the three extended methods gave either visible shading artifacts or high deviation of pixel value, while the authors’ proposed method demonstrated no visible artifacts and minimal deviation of pixel value in both the numerical simulations and physical experiments. Conclusions: For an interior micro-CT with an offset detector, the three extended reconstruction methods can perform well at a small detector offset but show strong artifacts at a large detector offset. When the detector offset is large, the authors’ proposed reconstruction method can outperform the three extended reconstruction methods by suppressing artifacts and maintaining pixel values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom

Purpose : X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosis and treatment is studied using a novel approach for three-dimensional (3D) x-ray fluorescence mapping (XFM) of gold nanoparticle (GNP)-loaded objects in a physical phantom at the technical level. Methods : All the theoretical analysis and experiments are conducted under the condition of using x-ray pencil beam and a compactly integrated x-ray spectrometer. The penetrability of the fluorescence x-rays from GNPs is first investigated by adopting a combination of BR12 with 70 mm/50 mm in thickness on the excitation/emission path to mimic the possible position of tumor goldin vivo. Then, a physical phantom made of BR12 is designed to translate in 3D space with three precise linear stages and subsequently the step by step XFM scanning is performed. The experimental technique named as background subtraction is applied to isolate the gold fluorescence from each spectrum obtained by the spectrometer. Afterwards, the attenuations of both the incident primary x-ray beam with energies beyond the gold K-edge energy (80.725 keV) and the isolated gold K{sub α} fluorescence x-rays (65.99 –69.80 keV) acquired after background subtraction are well calibrated, and finally the unattenuated K{sub α} fluorescence counts are used to realize mapping reconstruction and to describe the linear relationship between gold fluorescence counts and corresponding concentration of gold solutions. Results : The penetration results show that the goldK{sub α} fluorescence x-rays have sufficient penetrability for this phantom study, and the reconstructed mapping results indicate that both the spatial distribution and relative concentration of GNPs within the designed BR12 phantom can be well identified and quantified. Conclusions : Although the XFM method in this investigation is still studied at the technical level and is not yet practical for routinein vivo mapping tasks with GNPs, the current penetrability measurements and phantom study strongly suggest the feasibility to establish and develop a 3D XFM system.

61 RADIATION PROTECTION AND DOSIMETRY↗