Engineering Papers⌕ Search

Engineering topics

Wang, G.

Publications and source records attributed to Wang, G..

At least 127 records · Page 7

Status of the CCD development for the Dark Energy Spectroscopic Instrument

We describe improvements in CCD performance that have been achieved on 4k×4k, (15 μm)(2)-pixel, fully depleted CCDs for the Dark Energy Spectroscopic Instrument (DESI) [1]. With respect to our previous work on CCDs for the Dark Energy Camera and the Baryon Oscillation Spectroscopic Survey, our goals for the DESI CCD development were to improve read noise and quantum efficiency, improve the astrometric precision, and decrease pixel-size variations. We report experimental results on recently fabricated CCDs to be used in DESI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanism and Kinetics for Reaction of the Chemical Warfare Agent Simulant, DMMP( g ), with Zirconium(IV) MOFs: An Ultrahigh-Vacuum and DFT Study

The mechanism and kinetics of interactions between dimethyl methylphosphonate (DMMP), a key chemical warfare agent (CWA) simulant, and Zr 6 -based metal organic frameworks (MOFs) have been investigated with in situ infrared spectroscopy (IR), X-ray photoelectron spectroscopy (XPS), powder X-ray diffraction (PXRD), and DFT calculations. DMMP was found to adsorb molecularly to UiO-66 through the formation of hydrogen bonds between the phosphoryl oxygen and the free hydroxyl groups associated with Zr 6 nodes on the surface of crystallites and not within the bulk MOF structure. Unlike UiO-66, the infrared spectra for UiO-67 and MOF-808, recorded during DMMP exposure, suggest that uptake occurs through both physisorption and chemisorption. The XPS spectra of MOF-808 zirconium 3d electrons reveal a charge redistribution following exposure to DMMP. In addition, analysis of the phosphorus 2p electrons following exposure and thermal annealing to 600 K indicates that two types of stable phosphorus-containing species exist within the MOF. DFT calculations, used to guide the IR band assignments and to help interpret the XPS features, suggest that uptake is driven by nucleophilic addition of an OH group to DMMP with subsequent elimination of a methoxy substituent to form strongly bound methyl methylphosphonic acid (MMPA). The rates of product formation indicate that there are likely two distinct uptake processes, requiring rate constants that differ by approximately an order of magnitude. However, the rates of molecular uptake were found to be nearly identical to the rates of reaction, which strongly suggests that the reaction rates are diffusion-limited. Here, the final products were found to inhibit further reactions within the MOFs, and these products could not be thermally driven from the MOFs prior to decomposition of the MOFs themselves.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The electromechanical behavior of piezoelectric thin film composite diaphragms possessing in-plane stresses

Many piezoelectric microelectromechanical systems (MEMS) measure or generate acoustic signals via the motion of radially non-uniform, thin film composite plates. The composite layers provide piezoelectric actuation, structural support, electrode metallization, passivation, etc. Often, the layers are non-uniform over the plate and contain residual stresses introduced during the fabrication process. Accurate models of non-uniform composite plate mechanics are crucial for predicting and optimizing device performance. In this paper, an analytical solution for a radially non-uniform, piezoelectric, circular composite plate incorporating residual stress is derived. The analytical solution is compared to experimental measurements of a MEMS piezoelectric diaphragm. The results show the improved accuracy of the analytical model when including film stress, the speed of the analytical solution as compared to finite element analysis, the sensitivity of device performance to residual stress and the importance of accurate film stresses as model inputs. Finally, the analytical model presented is useful as a design optimization tool given the efficiency of the computational time, shown to be 275 times less than a comparable finite element analysis.

42 ENGINEERING↗

LDQ10: a compact ultra low-power radiation-hard 4 × 10 Gb/s driver array

Here, a High-speed and low-power VCSEL driver is an important component of the Versatile Link for the high-luminosity LHC (HL-LHC) experiments. A compact low-power radiation-hard 4 × 10 Gb/s VCSEL driver array (LDQ10) has been developed in 65 nm CMOS technology. Each channel in LDQ10 can provide a modulation current up to 8 mA and bias current up to 12 mA. Edge pre-emphasis is employed to compensate for the bandwidth limitations due to parasitic and the turn-on delay of VCSEL devices. LDQ10 occupies a chip area of 1900 μm × 1700 μm and consumes 130 mW power for typical current settings. The modulation amplitude degrades less than 5% after 300 Mrad total ionizing dose. LDQ10 can be directly wire-bonded to the VCSEL array and it is a suitable candidate for the Versatile Link.

42 ENGINEERING↗

Modeling Iridium-Based Trilayer and Bilayer Transition-Edge Sensors

Here, we report a model that can be used to calculate superconducting transition temperature of a transition-edge sensor (TES), which is either a normal metal-superconductor-normal metal trilayer or a normal metal-superconductor bilayer. The model allows the T C estimation of a trilayer when the normal metals at the bottom and at the top are different. Furthermore, the model includes the spin flip time of the normal metals. We also use the T C calculations from this model for selected Ir-based trilayers and bilayers to help understand potential designs of low T C TESs. A Au/Ir/Au trilayer can have a low T C because the superconducting order parameter is reduced with normal metals at both sides. On the other hand, an Ir/Pt bilayer can have a low T C because the much larger electron density of states of Pt reduces the superconducting order parameter more effectively. Moreover, the spin flip scattering of paramagnetic Pt also contributes to the T C reduction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization of Transition Edge Sensor Arrays for Cosmic Microwave Background Observations With the South Pole Telescope

In this paper, we describe the optimization of transition-edge-sensor (TES) detector arrays for the third-generation camera for the South PoleTelescope. The camera, which contains similar to 16 000 detectors, will make high-angular-resolution maps of the temperature and polarization of the cosmic microwave background. Our key results are scatter in the transition temperature of Ti/Au TESs is reduced by fabricating the TESs on a thin Ti(5 nm)/Au(5 nm) buffer layer and the thermal conductivity of the legs that support our detector islands is dominated by the SiOx dielectric in the microstrip transmission lines that run along the legs.

Ding, Junjia↗

Synthesis and crystal structure of the iridium(I) carbene complex with a pair of hydrogen wing tips

The iridium(I) cyclooctadiene complex with two (3-tert-butylimidazol-2-ylidene) ligands [(H-Im{sup t}Bu){sub 2}Ir(COD)]{sup +}PF{sub 6}{sup −} (C{sub 22}H{sub 32}PF{sub 6}IrN{sub 4}) has been prepared, and its crystal structure is determined by X-ray diffraction. Complex exhibits slightly distorted square planar configurations around the metal atom, which is coordinated by two H-Im{sup t}Bu ligands and one cyclooctadiene group. The new iridium carbene complex has a pair of hydrogen wing tips. The Ir−C{sub carbene} bond lengths are 2.066(5) and 2.052(5) Å, and the bond angle C−Ir−C between these bonds is 95.54(19)°. The dihedral angle between two imidazol-2-ylidene rings is 86.42°.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A novel technique for real-time estimation of edge pedestal density gradients via reflectometer time delay data

A new model-based technique for fast estimation of the pedestal electron density gradient has been developed. The technique uses ordinary mode polarization profile reflectometer time delay data and does not require direct profile inversion. Because of its simple data processing, the technique can be readily implemented via a Field-Programmable Gate Array, so as to provide a real-time density gradient estimate, suitable for use in plasma control systems such as envisioned for ITER, and possibly for DIII-D and Experimental Advanced Superconducting Tokamak. The method is based on a simple edge plasma model with a linear pedestal density gradient and low scrape-off-layer density. By measuring reflectometer time delays for three adjacent frequencies, the pedestal density gradient can be estimated analytically via the new approach. Using existing DIII-D profile reflectometer data, the estimated density gradients obtained from the new technique are found to be in good agreement with the actual density gradients for a number of dynamic DIII-D plasma conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam energy scan with asymmetric collision at RHIC

A beam energy scan of deuteron-gold collision, with center-of-mass energy at 19.6, 39, 62.4 and 200.7 GeV/n, was performed at the Relativistic Heavy Ion Collider in 2016 to study the threshold for quark-gluon plasma (QGP) production. The lattice, RF, stochastic cooling and other subsystems were in different configurations for the various energies. The operational challenges changed with every new energy. The operational experience at each energy, the operation performance, highlights and lessons of the beam energy scan are reviewed in this report.

43 PARTICLE ACCELERATORS↗

MILLIMETER TRANSIENT POINT SOURCES IN THE SPTpol 100 SQUARE DEGREE SURVEY

The millimeter transient sky is largely unexplored, with measurements limited to follow-up of objects detected at other wavelengths. High-angular-resolution telescopes, designed for measurement of the cosmic microwave background (CMB), offer the possibility to discover new, unknown transient sources in this band—particularly the afterglows of unobserved gamma-ray bursts (GRBs). Here, we use the 10 m millimeter-wave South Pole Telescope, designed for the primary purpose of observing the CMB at arcminute and larger angular scales, to conduct a search for such objects. During the 2012–2013 season, the telescope was used to continuously observe a 100 deg{sup 2} patch of sky centered at R.A. 23{sup h}30{sup m} and decl. −55° using the polarization-sensitive SPTpol camera in two bands centered at 95 and 150 GHz. These 6000 hr of observations provided continuous monitoring for day- to month-scale millimeter-wave transient sources at the 10 mJy level. One candidate object was observed with properties broadly consistent with a GRB afterglow, but at a statistical significance too low ( p = 0.01) to confirm detection.

79 ASTRONOMY AND ASTROPHYSICS↗

Procedure for measuring photon and vector meson circular polarization variation with respect to the reaction plane in relativistic heavy-ion collisions

The electromagnetic (EM) eld pattern created by spectators in relativistic heavy-ion collisions plants a seed of positive (negative) magnetic helicity in the hemisphere above (below) the reaction plane. Owing to the chiral anomaly, the magnetic helicity interacts with the fermionic helicity of the collision system, and causes photons emitted in upper- and lower-hemispheres to have different preferences in the circular polarization. Similar helicity separation for massive particles, due to the global vorticity, is also possible. In this paper, we lay down a procedure to measure the variation of the circular polarization w.r.t the reaction plane in relativistic heavy-ion collisions for massless photons, as well as similar polarization patterns for vector mesons decaying into two daughters. We propose to study the yield differentially and compare the yield between upper- and lower-hemispheres in order to identify and quantify such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗