Engineering Papers⌕ Search

Engineering topics

Wang, Fei

Publications and source records attributed to Wang, Fei.

At least 163 records · Page 9

Evolution of irradiation defects in Ti 2 AlC ceramics during heavy ion irradiation

Here, the evolution of irradiation defects in Ti 2 AlC under Kr ion irradiation at room and elevated temperatures has been investigated. The dependence of defect size and density on the irradiation dose and temperature was characterized by in-situ transmission electron microscopy (TEM) irradiation experiments. At 25-800 °C, interstitial-type dislocation loops with several nanometers in diameter form on the basal plane of Ti 2 AlC mostly with a Burgers vector of 1/2[0 0 0 1], and no voids have been observed. The number density of dislocation loops approaches saturation at a level of about 2 dpa at 800 °C. Ti 2 AlC samples remain crystalline in structure without amorphization or phase transformation. However, the localized disorder of atomic positions on the basal plane of the irradiated Ti 2 AlC was revealed by high-resolution transmission electron microscopy (HRTEM) studies, which increases with irradiation dose while decreases with elevated temperatures.

36 MATERIALS SCIENCE↗

An FPGA-Based Voltage Balancing Control for Multi-HV-IGBTs in Series Connection

The series connection of insulated gate bipolar transistors (IGBTs) allows operation at voltage levels higher than the rated voltage of one IGBT and has less power semiconductor costs compared to multilevel topologies. However, voltage unbalance during the switching transient is a challenge for series-connected device application. This paper presents an field-programmable gate array (FPGA)-based voltage balancing strategy for multiseries-connected high-voltage (HV)-IGBTs including an FPGA-based active voltage balancing control (AVBC) circuit integrated into the gate driver and the control for multiseries-connected IGBTs. As a result, the effectiveness of the control has been experimentally validated in a prototype using four 4.5 kV HV-IGBTs in series connection.

42 ENGINEERING↗

A Universal Organic Cathode for Ultrafast Lithium and Multivalent Metal Batteries

Abstract Low‐cost multivalent battery chemistries (Mg 2+ , Al 3+ ) have been extensively investigated for large‐scale energy storage applications. However, their commercialization is plagued by the poor power density and cycle life of cathodes. A universal polyimides@CNT (PI@CNT) cathode is now presented that can reversibly store various cations with different valences (Li + , Mg 2+ , Al 3+ ) at an extremely fast rate. The ion‐coordination charge storage mechanism of PI@CNT is systemically investigated. Full cells using PI@CNT cathodes and corresponding metal anodes exhibit long cycle life (>10000 cycles), fast kinetics (>20 C), and wide operating temperature range (−40 to 50 °C), making the low‐cost industrial polyimides universal cathodes for different multivalent metal batteries. The stable ion‐coordinated mechanism opens a new foundation for the development of high‐energy and high‐power multivalent batteries.

Fan, Xiulin↗

Short-Circuit Characterization and Protection of 10-kV SiC mosfet

This paper presents the characterization of the temperature-dependent short-circuit performance of a Gen3 10 kV/20 A silicon carbide (SiC) mosfet. The test platform consisting of a phase-leg configuration and a fast speed 10-kV solid state circuit breaker, with temperature control, is introduced in detail. A novel FPGA-based short-circuit protection circuit having a response time of 1.5 μs is proposed and integrated into the gate driver. The short-circuit protection is validated through the platform. The short-circuit characteristics for both the hard switching fault and fault under load (FUL) types at various dc-link voltages (from 500 V to 6 kV) are tested and discussed. The saturation current increases with dc-link voltage and achieves 360 A at 6 kV. Different from low voltage SiC devices, there is no current spike in FUL type of fault. The temperature-dependent short-circuit performance is also presented from 25 to 125 °C. The difference of short-circuit waveforms at various initial junction temperatures can be neglected. Here, a thermal model of the 10-kV SiC mosfet is built for the junction temperature estimation during the short circuit and for analysis of the initial junction temperature impact on the short-circuit performance.

10-kV SiC mosfet↗

Circular RNA expression profiles in placental villi from women with gestational diabetes mellitus

Highlights: • More than 40,000 circRNAs are sequenced in the placental villi. • The expression profile of circRNAs in GDM is different from that in controls. • The potential effects of many differential circRNAs are involve in the development of GDM. • Some differential circRNAs have binding sites of GDM-related miRNAs. Circular RNAs (circRNAs) have recently been shown to exert their effects on multiple pathological processes by acting as microRNA (miRNA) sponges. However, the roles of circRNAs in gestational diabetes mellitus (GDM) are largely unknown. This study aimed to identify the circRNAs involved in GDM and predict their potential biological functions. We first performed next-generation sequencing (NGS) to generate unbiased placental villi circRNA expression profiles of GDM and normal controls. In total, 48,270 circRNAs from the placental villi of the two groups were sequenced. Of these, 227 circRNAs were significantly up-regulated and 255 circRNAs were significantly down-regulated. Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) biological pathway analyses demonstrated that glycometabolism and lipometabolism processes, which are important in GDM development, were significantly enriched. Further analysis showed that most of the circRNAs harbored miRNA binding sites, and some were associated with GDM. These results showed that circRNAs are aberrantly expressed in the placental villi of GDM patients and play potential roles in the development of GDM.

60 APPLIED LIFE SCIENCES↗

Frequency support comparison for vanadium and lithium-ion BESSs using a converter-based grid emulator

Battery energy storage systems (BESSs) are commonly used for frequency support services in power systems because they have fast response times and can frequently inject and absorb active power. Lithium-ion (Li-ion) BESSs dominate the grid energy storage market now, but Vanadium redox flow (VRB) BESSs are predicted to contend in future markets for large-scale storage systems. Previously, a Li-ion BESS emulator has been developed for a grid emulation system known as the Hardware Testbed (HTB), which consists of converters controlled to emulate different power system components. In this paper, we develop a VRB BESS emulator with a VRB-specific internal battery model and a power electronics interface similar to that of the Li-ion BESS emulator. Then, we compare the effectiveness of the VRB and Li-ion technologies for primary frequency regulation and inertia emulation applications. It is concluded that these two technologies are virtually indistinguishable from the power system's perspective when conducting these services over a short period of time.

Boles, Jessica↗

High precision gate signal timing control based active voltage balancing scheme for series-connected fast switching field-effect transistors

Due to the low availability, high cost, and limited performance of high voltage power devices in high voltage high power applications, series-connection of low voltage switches is commonly considered. Practically, because of the dynamic voltage unbalance and the resultant reliability issue, switches in series-connection are not popular, especially for fast switching field-effect transistors such as silicon (Si) super junction MOSFETs, silicon carbide (SiC) JFETs, SiC MOSFETs, and gallium nitride (GaN) HEMTs, since their switching performance is highly sensitive to gate control, circuit parasitics, and device parameters. In the end, slight mismatch can introduce severe unbalanced voltage. This paper proposes an active voltage balancing scheme, including 1) tunable gate signal timing unit between series-connected switches with <; 1 ns precision resolution by utilizing a high resolution pulse-width modulator (HRPWM) which has existed in micro-controllers; and 2) online voltage unbalance monitor unit integrated with the gate drive as the feedback. Based on the latest generation 600-V Si CoolMOS, experimental results show that the dynamic voltage can be automatically well balanced in a wide range of operating conditions, and more importantly, the proposed scheme has no penalty for high-speed switching.

Zhang, Zheyu↗

Direct 400 Vdc to 1 Vdc power conversion with input series output parallel connection for data center power supplies

Data centers consume an ever-increasing amount of electricity because of the rapid growth of cloud computing and digital information storage. A high voltage point of load (HV POL) converter is proposed to convert the 400-VDC distribution voltage to 1-VDC within a single stage to increase the power conversion efficiency. A six-phase input series output parallel (ISOP) connected structure is implemented for the HV POL. The symmetrical controlled half bridge current doubler is selected as the converter topology in the ISOP structure. The full load efficiency is improved by 4% points compared with state of the art products. A voltage compensator has been designed in order to meet the strict dynamic voltage regulation requirement. A laboratory prototype has been built, and experimental results have been provided to verify the proposed HV POL with a single power conversion stage can meet the dynamic voltage regulation requirement for an on-board power supply with higher efficiency compared to the conventional architecture.

Cui, Yutian↗

Understanding middle-point inductance's effect on switching transients for multi-chip SiC package design with P-cell/N-cell concept

Middle-point inductance L_middle can be introduced in power module designs with P-cell/N-cell concept. In this paper, the effect of middle-point inductance on switching transients is analyzed first using frequency domain analysis. Then a dedicated multiple-chips power module is fabricated with the capability of varying L_middle, and extensive switching tests are conducted to evaluate the device’s switching performance at different L_middle. Experiment results show that as L_middle changes, different voltage stresses are imposed on the active switch and anti-parallel diode. For lower MOSFET’s turn-off, as L_middle goes up, the maximum voltage of lower MOSFET increases; however, the maximum voltage of anti-parallel diode decreases significantly. In addition to voltage spikes, it is observed that the active MOSFET’s turn-on loss will decrease at higher values of L_middle while its turn-off loss will increase. Detailed analysis of this loss variation is presented. The analysis and experiment results will provide design guidelines for multiple-chips power module package design with P-cell/N-cell concept.

Yang, Fei↗

Online condition monitoring based dead-time compensation for high frequency SiC voltage source inverter

Dead-time, device output capacitance, and other non-ideal characteristics cause voltage error for the midpoint PWM voltage of the semiconductor phase-leg employed in a voltage-source inverter (VSI). Voltage-second balancing is a well-known concept to mitigate this distortion and improve converter power quality. This paper proposes a unique voltage-second balancing scheme for a SiC based voltage source inverter using online condition monitoring of turn-off delay time and drain-source voltage rise/fall time. This data is sent to the micro-controller to be used in an algorithm to actively adjust the duty cycle of the input PWM gate signals to match the voltage-second of the non-ideal output voltage with an ideal output voltage-second. The monitoring system also allows for this implementation to eliminate the need for precise current sensing and allows for the implementation to be load independent. Dynamic current sensing is still a developing technology, and each load has a unique effect on the output voltage distortion. Test results for a 1 kW half-bridge inverter implementing this monitoring system and voltage-second balancing scheme show a 70% enhancement on the error against the ideal fundamental current value of the output current and a 2% THD improvement on the output current low frequency harmonics.

Dyer, Jacob↗

Common-mode noise reduction with impedance balancing in DC-fed motor drives

Unlike conventional passive or active filters, an impedance balancing circuit reduces the common-mode (CM) electromagnetic interference (EMI) noise by establishing an impedance balancing bridge. The EMI noise can be significantly reduced when the impedance bridge is designed to be well balanced. This paper investigates impedance balancing circuits in Dc-fed motor drive systems where both DC input and AC output need to meet EMI standards and thus EMI filters are needed for both sides. An impedance balancing circuit is proposed to reduce both DC and AC side CM noise. Two auxiliary branches are added to the conventional passive filters to establish an impedance bridge and reduce CM noise. The design criteria are presented, and the impact of the proposed impedance balancing circuit on both sides CM noise are investigated. It shows that the proposed impedance balancing circuit can reduce DC side and AC side CM noise based on different mechanisms. The CM noise reduction performance of the proposed method does not depend on the motor and cable models. Experiment results are presented to demonstrate the feasibility and effectiveness of the proposed method.

Chen, Ruirui↗

Common-mode inductor saturation analysis and design optimization based on spectrum concept

Understanding the CM inductor core saturation mechanism and reducing core flux density is critical for CM inductor design optimization. Instead of a time domain method, this paper introduces frequency domain spectrum concept for CM inductor core saturation analysis and design optimization, which will provide designers a better understanding of CM inductor design. First, both core permeability and converter modulation index's opposite influence on DM flux density and CM flux density are identified. Then, CM flux density is further investigated based on the spectrum concept. Three components in the CM inductor which may cause large CM flux density and core saturation are summarized: (1) switching frequency related components, (2) impedance resonance frequency related components, and (3) modulation frequency related components. Each component is investigated for CM flux density reduction and filter design optimization. A connecting AC and DC side midpoint with notch filter structure is proposed to reduce modulation frequency related components. Experiment results are presented to verify the proposed concept and method.

Chen, Ruirui↗

Short circuit characterization of 3rdgeneration 10 kV SiC MOSFET

The short circuit performance of a 3 rd generation 10 kV/20 A SiC MOSFET with short channel is characterized in this paper. The platform consisting of a phase-leg configuration, which can test both hard switching fault (HSF) and fault under load (FUL) types of fault, is introduced in detail. A Si IGBT based solid state circuit breaker is developed for short circuit test. The short circuit protection having a response time of 1.5 μs is validated by the test platform. The short circuit characteristics for both the HSF and FUL types at 6 kV DC-link are presented and analyzed.

Ji, Shiqi↗

Development of a Converter-Based Transmission Line Emulator with Three-Phase Short-Circuit Fault Emulation Capability

A transmission line emulator has been developed to flexibly represent interconnected ac lines under normal operating conditions in a voltage source converter (VSC)-based power system emulation platform. As the most serious short-circuit fault condition, the three-phase short-circuit fault emulation is essential for power system studies. Here, this paper proposes a model to realize a three-phase short-circuit fault emulation at different locations along a single transmission line or one of several parallel-connected transmission lines. At the same time, a combination method is proposed to eliminate the undesired transients caused by the current reference step changes while switching between the fault state and the normal state. Experiment results verify the developed transmission line three-phase short-circuit fault emulation capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗