Engineering Papers⌕ Search

Engineering topics

Wang, F

Publications and source records attributed to Wang, F.

At least 19 records

Ultrabroadband THz conductivity of gated graphene in- and out-of-equilibrium

We employ ultrabroadband terahertz (THz) spectroscopy to expose the high-frequency transport properties of Dirac fermions in monolayer graphene. By controlling the carrier concentration via tunable electrical gating, both equilibrium and transient optical conductivities are obtained for a range of Fermi levels. The frequency-dependent equilibrium response is determined through a combination of time-domain THz and Fourier-transform infrared spectroscopy for energies up to the near-infrared, which also provides a measure of the gate-voltage dependent Fermi level. Transient changes in the real and imaginary parts of the graphene conductivity are electro-optically resolved for frequencies up to 15 THz after near-infrared femtosecond excitation, both at the charge-neutral point and for higher electrostatic-doping levels. Modeling of the THz response provides insight into changes of the carrier spectral weights and scattering rates, and reveals an additional broad-frequency ($$\approx$$ 8 THz) component to the photo-induced response, which we attribute to the zero-momentum mode of quantum-critical transport observed here in large-area CVD graphene.

Coslovich, G↗

Access Patterns and Performance Behaviors of Multi-layer Supercomputer I/O Subsystems under Production Load

Scientific computing workloads at HPC facilities have been shifting from traditional numerical simulations to AI/ML applications for training and inference while processing and producing ever-increasing amounts of scientific data. To address the growing need for increased storage capacity, lower access latency, and higher bandwidth, emerging technologies such as non-volatile memory are integrated into supercomputer I/O subsystems. With these emerging trends, we need a better understanding of the multilayer supercomputer I/O systems and ways to use these subsystems efficiently. In this work, we study the I/O access patterns and performance characteristics of two representative supercomputer I/O subsystems. Through an extensive analysis of year-long I/O logs on each system, we report new observations in I/O reads and writes, unbalanced use of storage system layers, and new trends in user behaviors at the HPC I/O middleware stack.

Bez, JL↗

Highly Enhanced Curie Temperature in Ga-Implanted Fe3GeTe2 van der Waals Material

Among many efforts in the research of van der Waals (vdW) magnetic materials, increasing the Curie temperature above room temperature has been at the center of research in developing spintronics technology using vdW materials. Here an effective and reliable method of increasing the Curie temperature of ferromagnetic Fe3GeTe2 vdW materials by Ga implantation is reported. It is found that implanting Ga into Fe3GeTe2 by the amount of 10-3 Ga Å-3 could greatly enhance the Fe3GeTe2 Curie temperature by almost 100%. Spatially resolved microdiffraction and element-resolved X-ray absorption spectroscopy show little changes in the Fe3GeTe2 crystal structure and Fe valence state. In addition, the Ga implantation changes the Fe3GeTe2 magnetization from out-of-plane direction at low temperature to in-plane direction at high temperature. The result opens a new opportunity for tailoring the magnetic properties of vdW materials beyond room temperature.

Yang, M↗

SU-D-202-04: Validation of Deformable Image Registration Algorithms for Head and Neck Adaptive Radiotherapy in Routine Clinical Setting

Purpose: To evaluate the ROI contours and accumulated dose difference using different deformable image registration (DIR) algorithms for head and neck (H&N) adaptive radiotherapy. Methods: Eight H&N cancer patients were randomly selected from the affiliated hospital. During the treatment, patients were rescanned every week with ROIs well delineated by radiation oncologist on each weekly CT. New weekly treatment plans were also re-designed with consistent dose prescription on the rescanned CT and executed for one week on Siemens CT-on-rails accelerator. At the end, we got six weekly CT scans from CT1 to CT6 including six weekly treatment plans for each patient. The primary CT1 was set as the reference CT for DIR proceeding with the left five weekly CTs using ANACONDA and MORFEUS algorithms separately in RayStation and the external skin ROI was set to be the controlling ROI both. The entire calculated weekly dose were deformed and accumulated on corresponding reference CT1 according to the deformation vector field (DVFs) generated by the two different DIR algorithms respectively. Thus we got both the ANACONDA-based and MORFEUS-based accumulated total dose on CT1 for each patient. At the same time, we mapped the ROIs on CT1 to generate the corresponding ROIs on CT6 using ANACONDA and MORFEUS DIR algorithms. DICE coefficients between the DIR deformed and radiation oncologist delineated ROIs on CT6 were calculated. Results: For DIR accumulated dose, PTV D95 and Left-Eyeball Dmax show significant differences with 67.13 cGy and 109.29 cGy respectively (Table1). For DIR mapped ROIs, PTV, Spinal cord and Left-Optic nerve show difference with −0.025, −0.127 and −0.124 (Table2). Conclusion: Even two excellent DIR algorithms can give divergent results for ROI deformation and dose accumulation. As more and more TPS get DIR module integrated, there is an urgent need to realize the potential risk using DIR in clinical.

60 APPLIED LIFE SCIENCES↗

SU-F-T-560: Measurement of Dose Blurring Effect Due to Respiratory Motion for Lung Stereotactic Body Radiation Therapy (SBRT) Using Monte Carlo Based Calculation Algorithm

Purpose: Intra-fractional tumor motion due to respiration may potentially compromise dose delivery for SBRT of lung tumors. Even sufficient margins are used to ensure there is no geometric miss of target volume, there is potential dose blurring effect may present due to motion and could impact the tumor coverage if motions are larger. In this study we investigated dose blurring effect of open fields as well as Lung SBRT patients planned using 2 non-coplanar dynamic conformal arcs(NCDCA) and few conformal beams(CB) calculated with Monte Carlo (MC) based algorithm utilizing phantom with 2D-diode array(MapCheck) and ion-chamber. Methods: SBRT lung patients were planned on Brainlab-iPlan system using 4D-CT scan and ITV were contoured on MIP image set and verified on all breathing phase image sets to account for breathing motion and then 5mm margin was applied to generate PTV. Plans were created using two NCDCA and 4-5 CB 6MV photon calculated using XVMC MC-algorithm. 3 SBRT patients plans were transferred to phantom with MapCheck and 0.125cc ion-chamber inserted in the middle of phantom to calculate dose. Also open field 3×3, 5×5 and 10×10 were calculated on this phantom. Phantom was placed on motion platform with varying motion from 5, 10, 20 and 30 mm with duty cycle of 4 second. Measurements were carried out for open fields as well 3 patients plans at static and various degree of motions. MapCheck planar dose and ion-chamber reading were collected and compared with static measurements and computed values to evaluate the dosimetric effect on tumor coverage due to motion. Results: To eliminate complexity of patients plan 3 simple open fields were also measured to see the dose blurring effect with the introduction of motion. All motion measured ionchamber values were normalized to corresponding static value. For open fields 5×5 and 10×10 normalized central axis ion-chamber values were 1.00 for all motions but for 3×3 they were 1 up to 10mm motion and 0.97 and 0.87 for 20 and 30mm motion respectively. For SBRT plans central axis dose values were within 1% upto 10mm motions but decreased to average of 5% for 20mm and 8% for 30mm motion. Mapcheck comparison with static showed penumbra enlargement due to motion blurring at the edges of the field for 3×3,5×5,10×10 pass rates were 88% to 12%, 100% to 43% and 100% to 63% respectively as motion increased from 5 to 30mm. For SBRT plans MapCheck mean pass rate were decreased from 73.8% to 39.5% as motion increased from 5mm to 30mm. Conclusion: Dose blurring effect has been seen in open fields as well as SBRT lung plans using NCDCA with CB which worsens with increasing respiratory motion and decreasing field size(tumor size). To reduce this effect larger margins and appropriate motion reduction techniques should be utilized.

60 APPLIED LIFE SCIENCES↗

SU-F-T-622: Comparative Analysis of Pencil Beam and Anisotropic Analytical Algorithm (AAA) for Stereotactic Body Radiation Therapy (SBRT) of Thoracic Spine

Purpose: To compare the impact of Pencil Beam(PB) and Anisotropic Analytic Algorithm(AAA) dose calculation algorithms on OARs and planning target volume (PTV) in thoracic spine stereotactic body radiation therapy (SBRT). Methods: Ten Spine SBRT patients were planned on Brainlab iPlan system using hybrid plan consisting of 1–2 non-coplanar conformal-dynamic arcs and few IMRT beams treated on NovalisTx with 6MV photon. Dose prescription varied from 20Gy to 30Gy in 5 fractions depending on the situation of the patient. PB plans were retrospectively recalculated using the Varian Eclipse with AAA algorithm using same MUs, MLC pattern and grid size(3mm).Differences in dose volume parameters for PTV, spinal cord, lung, and esophagus were analyzed and compared for PB and AAA algorithms. OAR constrains were followed per RTOG-0631. Results: Since patients were treated using PB calculation, we compared all the AAA DVH values with respect to PB plan values as standard, although AAA predicts the dose more accurately than PB. PTV(min), PTV(Max), PTV(mean), PTV(D99%), PTV(D90%) were overestimated with AAA calculation on average by 3.5%, 1.84%, 0.95%, 3.98% and 1.55% respectively as compared to PB. All lung DVH parameters were underestimated with AAA algorithm mean deviation of lung V20, V10, V5, and 1000cc were 42.81%,19.83%, 18.79%, and 18.35% respectively. AAA overestimated Cord(0.35cc) by mean of 17.3%; cord (0.03cc) by 12.19% and cord(max) by 10.5% as compared to PB. Esophagus max dose were overestimated by 4.4% and 5cc by 3.26% for AAA algorithm as compared to PB. Conclusion: AAA overestimated the PTV dose values by up to 4%.The lung DVH had the greatest underestimation of dose by AAA versus PB. Spinal cord dose was overestimated by AAA versus PB. Given the critical importance of accuracy of OAR and PTV dose calculation for SBRT spine, more accurate algorithms and validation of calculated doses in phantom models are indicated.

60 APPLIED LIFE SCIENCES↗

SU-F-T-632: On the Use of Intensity Modulated Arc Therapy for Thoracic Vertebral Metastases SBRT Treatment

Purpose: To retrospectively evaluate quality, efficiency and delivery accuracy of intensity modulated arc therapy (IMAT) plans for thoracic-vertebral metastases using stereotactic body radiotherapy (SBRT). Methods: After obtaining approval of RPC-benchmark plan, seven previously treated thoracic-vertebral metastases patients with non-coplanar hybrid arcs(NC-HA)using 1–2 3D-dynamic conformal partial-arcs plus 7–9 IMRT-beams were re-optimized with IMAT using 3 full co-planar arcs. Tumors were located between T2–T7. T1/T2-weighted MRI images were co-registered with planning-CT. PTVs were between 24.3–240.1cc(median=48.1cc). Prescription was 30Gy in 5 fractions with 6-MV beams at Novalis-TX consisting of HD-MLC.Plans were compared for target coverage:conformality index(CI),homogeneity index(HI),PTVD90. Organs-at-risks(OARs)was evaluated for spinal cord(Dmax, D0.35cc, and D1.2cc), esophagus(Dmax and D5cc),heart(Dmax, D15cc)and lung(V5 and V10). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance(QA) plan. Beam-on time was recorded and a gamma index was used to compare agreement between planned and measured doses. Results: SBRT IMAT plans resulted in superior CI(1.02 vs. 1.36, p=0.05) and HI (0.14 vs. 0.27, p=0.01). PTVD90 was improved but statistically insignificant (31.0 vs. 30.4Gy, p=0.38). IMAT resulted in statistically significant improvements in OARs sparing: esophagus max(22.5 vs. 27.0Gy, p=0.03), esophagus 5cc (17.6 vs. 21.5Gy, p=0.02) and heart max(13.1 vs. 15.8Gy, p=0.03). Spinal cord,lung V5 and V10 were lower but statistically insignificant. Average total MU and beam-on time were 2598±354 vs. 3542±495 and 4.7±0.6 min vs. 7.1±1.0min for IMAT vs. NC-HA (without accounting for couch kicks time for NC-HA). IMAT plans demonstrated an accurate dose delivery of 95.5±1.0% for clinical gamma passing-rate of 2%/2mm criteria on MapCHECK, that was comparable to NC-HA plans. Conclusion: IMAT plans provided highly conformal and homogeneous dose distributions to target and reduced OARs doses compared to NC-HA. Total MU was reduced by a factor of 1.4 and subsequently decreased treatment times significantly - potentially minimizing intra-fraction motion error and owing to patient comfort. SBRT using IMAT planning for single fraction thoracic-vertebrae metastases will be investigated.

60 APPLIED LIFE SCIENCES↗

SU-F-T-647: Linac-Based Stereotactic Radiosurgery (SRS) in the Treatment of Trigeminal Neuralgia: Detailed Description of SRS Procedural Technique and Reported Clinical Outcomes

Purpose: SRS is an effective non-invasive alternative treatment modality with minimal-toxicity used to treat patients with medically/surgically refractory trigeminal neuralgia root(TNR) or those who may not tolerate surgical intervention. We present our linac-based SRS procedure for TNR treatment and simultaneously report our clinical outcomes. Methods: Twenty-eight TNR-patients treated with frame-based SRS at our institution (2009–2015) with a single-fraction point-dose of 60-80Gy to TNR were included in this IRB-approved study. Experienced neurosurgeon and radiation oncologist delineated the TNR on 1.0mm thin 3D-FIESTA-MRI that was co-registered with 0.7mm thin planning-CT. Treatment plans were generated in iPlan (BrainLAB) with a 4-mm diameter cone using 79 arcs with differential-weighting for Novalis-TX 6MV-SRS(1000MU/min) beam and optimized to minimize brainstem dose. Winston-Lutz test was performed before each treatment delivery with sub-millimeter isocenter accuracy. Quality assurance of frame placement was maintained by helmet-bobble-measurement before simulation-CT and before patient setup at treatment couch. OBI-CBCT scan was performed for patient setup verification without applying shifts. On clinical follow up, treatment response was assessed using Barrow Neurological Institute Pain Intensity Score(BNI-score:I–V). Results: 26/28 TNR-patients (16-males/10-females) who were treated with following single-fraction point-dose to isocenter: 80Gy(n=22),75Gy(n=1),70Gy(n=2) and 60Gy(n=1, re-treatment) were followed up. Median follow-up interval was 8.5-months (ranged:1–48.5months). Median age was 70-yr (ranged:43–93-yr). Right/left TNR ratio was 15/11. Delivered total # of average MUs was 19034±1204. Average beam-on-time: 19.0±1.3min. Brainstem max-dose and dose to 0.5cc were 13.3±2.4Gy (ranged:8.1–16.5Gy) and 3.6±0.4Gy (ranged:3.0–4.9Gy). On average, max-dose to optic-apparatus was ≤1.2Gy. Mean value of max-dose to eyes/lens was 0.26Gy/0.11Gy. Overall, 20-patients (77%) responded to treatment: 5(19%) achieved complete pain relief without medication (BNI score: I); 5(19%) had no-pain, decreased medication (BNI-score:II); 2(7.7%) had no-pain, but, continued medication (BNI-score:IIIA), and 8(30.8%) had pain that was well controlled by medication (BNI-score: IIIB). Six-patients (23.0%) did not respond to treatment (BNI-score:IV–V). Neither cranial nerve deficit nor radio-necrosis of temporal lobe was clinically observed. Conclusion: Linac-based SRS for medically/surgically refractory TNR provided an effective treatment option for pain resolution/control with very minimal if any normal tissue toxicity. Longer follow up of these patients is anticipated/needed to confirm our observations.

60 APPLIED LIFE SCIENCES↗

WE-H-BRA-02: Radiobiological Modeling of Tumor Control Probability (TCP) and Radiation-Induced Pneumonitis (RP) for Lung Cancer Patients Treated with Monte Carlo-Based Lung SBRT

Purpose: To present radiobiological modeling of TCP using tumor size-adjusted BED(s-BED)and PTV(D99) to lung SBRT patients treated with X-ray Voxel Monte Carlo(XVMC) algorithm, apply parameterized Lyman-NTCP model to predict grade-2 RP and subsequently, compare with clinical outcomes/observations. Methods: Dosimetric parameters and clinical follow-up for XVMC-based lung-SBRT patients were retrospectively evaluated. Patients were treated at Novalis-TX with hybrid(2 non-coplanar partial-arcs plus 3–6 static-beams)plan using HD-MLC/6MV-SRS-beam.For TCP,s-BED modelling was utilized: TCP=EXP[sBED-TCD50]/k/(1.0+EXP[sBED-TCD50]/k), where k=31Gy corresponding to TCD50=0Gy and s-BED was defined as BED10 minus 10 times the tumor diameter(in centimeters)by Ohri et al.(IJROBP,2012). For 2-yr local-control, we used more-realistic MC-computed PTVD99 as a predictive parameter, s-BED(D99).Due to relatively shorter median follow-up interval(12-months),Kaplan-Meier curves were generated to estimate 2-yr observed local-control and compared to predicted-rate by TCP modeling. For NTCP, we employed parameterized Lyman-NTCP model utilizing normal-lung DVH and α/β=3Gy fitted to predict grade-2 RP after lung-SBRT. Results: Total 108 patients (137 tumors) treated for 35–70Gy in 3–5 fractions, either primary-lung(n=74)or metastatic-lung(n=53)tumors were included.F or the given prescription dose with MC-computed MUs, 2-yr local-control rates with s-BED(D99) was 87±8%. Kaplan-Meier generated observed local-control rate at 2-yr was 87.5%,suggesting that PTV(D99) could be a potential predictor (p-value=0.38). Observed vs predicted TCP for primary-lung tumors and metastatic tumors were 97% vs 88±7% and 94% vs 86±9%.NTCP model predicted well for symptomatic-RP with predicted vs observed (3±5% vs 2%). Radiographic and clinically significant RP was observed in 13% and 2% of patients. Higher rates of radiographic change were observed in patients who received >50Gy compared to ≤50Gy(24% vs 10%). Conclusion: Utilizing MC-computed PTVD99, our TCP results were well correlated with clinical outcome. The predicted grade-2 RP rate was comparable to clinical observations. Clinical application of these radiobiological models may potentially allow for target dose escalation and/or lung-toxicity reduction. Further validation of these radiobiological models with longer follow up interval for large cohorts of lung-SBRT patients is anticipated.

60 APPLIED LIFE SCIENCES↗

SU-E-T-304: Dosimetric Comparison of Cavernous Sinus Tumors: Heterogeneity Corrected Pencil Beam (PB-Hete) Vs. X-Ray Voxel Monte Carlo (XVMC) Algorithms for Stereotactic Radiotherapy (SRT)

Purpose: To compare dose distributions calculated using PB-hete vs. XVMC algorithms for SRT treatments of cavernous sinus tumors. Methods: Using PB-hete SRT, five patients with cavernous sinus tumors received the prescription dose of 25 Gy in 5 fractions for planning target volume PTV(V100%)=95%. Gross tumor volume (GTV) and organs at risk (OARs) were delineated on T1/T2 MRI-CT-fused images. PTV (range 2.1–84.3cc, mean=21.7cc) was generated using a 5mm uniform-margin around GTV. PB-hete SRT plans included a combination of non-coplanar conformal arcs/static beams delivered by Novalis-TX consisting of HD-MLCs and a 6MV-SRS(1000 MU/min) beam. Plans were re-optimized using XVMC algorithm with identical beam geometry and MLC positions. Comparison of plan specific PTV(V99%), maximal, mean, isocenter doses, and total monitor units(MUs) were evaluated. Maximal dose to OARs such as brainstem, optic-pathway, spinal cord, and lenses as well as normal tissue volume receiving 12Gy(V12) were compared between two algorithms. All analysis was performed using two-tailed paired t-tests of an upper-bound p-value of <0.05. Results: Using either algorithm, no dosimetrically significant differences in PTV coverage (PTVV99%,maximal, mean, isocenter doses) and total number of MUs were observed (all p-values >0.05, mean ratios within 2%). However, maximal doses to optic-chiasm and nerves were significantly under-predicted using PB-hete (p=0.04). Maximal brainstem, spinal cord, lens dose and V12 were all comparable between two algorithms, with exception of one patient with the largest PTV who exhibited 11% higher V12 with XVMC. Conclusion: Unlike lung tumors, XVMC and PB-hete treatment plans provided similar PTV coverage for cavernous sinus tumors. Majority of OARs doses were comparable between two algorithms, except for small structures such as optic chiasm/nerves which could potentially receive higher doses when using XVMC algorithm. Special attention may need to be paid on a case-by-case basis when planning for sinus SRT based on tumor size and location to OARs particularly the optic apparatus.

60 APPLIED LIFE SCIENCES↗

SU-E-T-322: Dosimetric Evaluation of Rib Dose in Peripheral Lung Tumors Treated with X-Ray Voxel Monte Carlo (XVMC) Based Lung Stereotactic Body Radiotherapy (SBRT) Following RTOG 0915 Guidelines

Purpose: To evaluate XVMC computed rib doses for peripherally located non-small-cell-lung tumors treated with SBRT following RTOG-0915 guidelines. Methods: Twenty patients with solitary peripherally located non-small-cell-lung tumors were treated using XVMC-based SBRT to 50–54Gy in 5−3 fractions, respectively, for PTV(V100%)=95%. Based on 4D-CT, ITV was delineated on MaximumIP images and organs-at-risk(OARs) including ribs were contoured on MeanIP images. Mean PTV(ITV+5mm uniform margin) was 46.1±38.7cc (range, 11.1–163.0cc). XVMC SBRT treatment plans were generated with a combination of non-coplanar 3D-conformal arcs/beams, and were delivered by Novalis-TX consisting of HD-MLCs and a 6MV-SRS(1000MU/min) beam, following RTOG-0915 criteria. XVMC rib maximum dose and dose to <1cc, <5cc, <10cc were evaluated as a function of PTV, prescription dose and 3D-distance from tumor isocenter to the most proximal rib contour. Plans were re-computed using heterogeneity-corrected pencil-beam (PB-hete) algorithm utilizing identical beam geometry/MLC positions and MUs and subsequently compared to XVMC. Results: XVMC average maximum rib dose was 50.9±6.4Gy (range, 35.1–59.3Gy). XVMC mean rib dose to <1cc was 41.6±5.6Gy (range, 27.9–47.9Gy), <5cc was 31.2±7.3Gy (range, 10.6–43.1Gy), and <10cc was 21.2±8.7Gy (range, 1.1–36Gy), respectively. For the given prescription, correlation between PTV and rib doses to <5cc (p=0.005) and <10cc (p=0.018) was observed. 3D-distance from the tumor isocenter to the proximal rib contour strongly correlated with maximum rib dose (p=0.0001). PB-hete algorithm overestimated maximum rib dose and dose to <1cc, <5cc, and <10cc of ribs by 5%, 3%, 3%, and 3%, respectively. Conclusion: PB-hete overestimates ribs dose relative to XVMC. Since all the clinical XVMC plans were generated without compromising the target coverage (per RTOG-0915), almost all patient’s ribs doses were higher than the protocol guidelines. As expected, larger tumor size and proximity to ribs received higher absolute dose to ribs. Prospective observation is needed to determine if XVMC delivered rib doses correlates with patient symptoms including chest wall pain and/or rib fractures.

60 APPLIED LIFE SCIENCES↗

SU-E-T-625: Potential for Reduced Radiation Induced Toxicity for the Treatment of Inoperable Non-Small-Cell Lung Cancer Using RapidArc Planning

Purpose: To investigate the feasibility of using RapidArc (RA) treatment planning to reduce irradiation volume of normal lung and other organs at risk (OARs) in the treatment of inoperable non-small-cell lung cancer (NSCLC) patients. Methods: A retrospective treatment planning and delivery study was performed to compare target coverage and the volumes of the normal lung, spinal cord, heart and esophagus on 4D-CT scan above their dose tolerances delivered by RA vs. IMRT for ten inoperable NSCLC patients (Stage I-IIIB). RA plans consisted of either one-full or two-partial co-planar arcs used to treat 95% of the planning target volume (PTV) with 6MV beam to a prescription of 66Gy in 33 fractions. IMRT plans were generated using 5–7 co-planar fields with 6MV beam. PTV coverage, dose-volume histograms, homogeneity/conformity indices (CI), total number of monitor units(MUs), beam-on time and delivery accuracy were compared between the two treatment plans. Results: Similar target coverage was obtained between the two techniques. RA (CI=1.02) provided more conformal plans without loss of homogeneity compared to IMRT plans (CI=1.12). Compared to IMRT, RA achieved a significant median dose reduction in V10 (3%), V20 (8%), and mean lung dose (3%) on average, respectively. On average, V5 was comparable between the two treatment plans. RA reduced mean esophagus (6%), mean heart (18%), and maximum spinal cord dose (7%), on average, respectively. Total number of MUs and beam-on time were each reduced almost by a factor of 2 when compared to IMRT-patient comfort, reduced intra-fraction-motion and leakage dose. The average IMRT and RA QA pass rate was about 98% for both types of plans for 3%/3mm criterion. Conclusion: Compared to IMRT plans, RA provided not only comparable target coverage, but also improved conformity, treatment time, and significant reduction in irradiation of OARs. This may potentially allow for target dose escalation without increase in normal tissue toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗