Engineering Papers⌕ Search

Engineering topics

Wagner, Eric

Publications and source records attributed to Wagner, Eric.

List-Mode source injection algorithm for detectors with arbitrary pose and trajectory

environments, introducing actual sources is usually neither feasible nor economical. It is more practical to move the detector (whether airborne, vehicle-borne, or human-portable) through the test environment and then later artificially superimpose either measured or simulated source signatures on the recorded background data. We present a source injection (SI) algorithm that inserts source events into list-mode background data. It is designed to accommodate cases where “injection data” are available only at a limited set of locations. Stochastic methods are employed both to select source events from a measured dataset containing both source and background events, and to scale the number of selected events to match the field conditions of detector-source distance, air attenuation, acquisition duration, and the relative strength of the measured and injected sources. The algorithm is deployed as part of the Airborne Radiation Enhanced-sensor System (ARES) Advanced Technology Demonstration, and is applied to field data obtained using the ARES detector system. For this helicopter-borne detection system, we describe a practical ground-based measurement scheme for acquiring data for later injection. These data are then injected into background data acquired during flight, where arbitrary detector poses and trajectories are possible. Similar flight paths are traversed with and without actual 137Cs and 60Co sources present. SI is applied to the source-absent datasets, and the results are compared to the source-present datasets. SI output is found to be consistent with measured activity within the estimated uncertainties in GPS position and source strength.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XSim: A Radiological Data Simulation Architecture

Report is a Technical Standard report for FEMA NIRT project managed by NA-42 and describes XSim architecture and XML format as a means to minimize the effort required for a field application in producing data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave Enhanced Direct Cracking of Hydrocarbon Feedstock for Energy Efficient Production of Ethylene and Propylene

This project demonstrated microwave cracking of ethane with good product conversion and ethylene selectivity, with a short residence time (~0.001 sec). The laboratory scale equipment was designed and built, along with concept designs for larger scale implementation. The system was operated below atmospheric pressures, in the range of 15-55 torr, with argon as a carrier gas. The measured products included hydrogen, methane, acetylene, and ethylene. The results followed similar trends to those predicted by the modeling software SPYRO®, with the exception that the microwave appeared to produce slightly lower amounts of ethylene and methane, although enhanced analytical analysis should reduce the difference. Continued testing will be required to verify these results and quantify the energy consumption of microwave vs. conventional. The microwave cracking process is an attractive option due to the possibility of selectively heating the reaction volume rather than the reactor walls, which may allow novel reactor designs that result in more efficient production of ethylene. Supplemental studies are needed to continue the laboratory testing and refine processing parameters.

02 PETROLEUM↗