Engineering Papers⌕ Search

Engineering topics

Vogt, Stefan

Publications and source records attributed to Vogt, Stefan.

Cadmium alters whole animal ionome and promotes the re-distribution of iron in intestinal cells of Caenorhabditis elegans

The chronic exposure of humans to the toxic metal cadmium (Cd), either occupational or from food and air, causes various diseases, including neurodegenerative conditions, dysfunction of vital organs, and cancer. While the toxicology of Cd and its effect on the homeostasis of biologically relevant elements is increasingly recognized, the spatial distribution of Cd and other elements in Cd toxicity-caused diseases is still poorly understood. Here, we use Caenorhabditis elegans as a non-mammalian multicellular model system to determine the distribution of Cd at the tissue and cellular resolution and its effect on the internal levels and the distribution of biologically relevant elements. Using inductively coupled plasma-mass spectrophotometry (ICP-MS), we show that exposure of worms to Cd not only led to its internal accumulation but also significantly altered the C. elegans ionome. Specifically, Cd treatment was associated with increased levels of toxic elements such as arsenic (As) and rubidium (Rb) and a decreased accumulation of essential elements such as zinc (Zn), copper (Cu), manganese (Mn), calcium (Ca), cobalt (Co) and, depending on the Cd-concentration used in the assay, iron (Fe). We regarded these changes as an ionomic signature of Cd toxicity in C. elegans. We also show that supplementing nematode growth medium with Zn but not Cu, rescues Cd toxicity and that mutant worms lacking Zn transporters CDF-1 or SUR-7, or both are more sensitive to Cd toxicity. Finally, using synchrotron X-Ray fluorescence Microscopy (XRF), we showed that Cd significantly alters the spatial distribution of mineral elements. The effect of Cd on the distribution of Fe was particularly striking: while Fe was evenly distributed in intestinal cells of worms grown without Cd, in the presence of Cd, Fe, and Cd co-localized in punctum-like structures in the intestinal cells. Together, this study advances our understanding of the effect of Cd on the accumulation and distribution of biologically relevant elements. Considering that C. elegans possesses the principal tissues and cell types as humans, our data may have important implications for future therapeutic developments aiming to alleviate Cd-related pathologies in humans.

59 BASIC BIOLOGICAL SCIENCES↗

Accelerated deep self-supervised ptycho-laminography for three-dimensional nanoscale imaging of integrated circuits

Three-dimensional inspection of nanostructures such as integrated circuits is important for security and reliability assurance. Two scanning operations are required: ptychographic to recover the complex transmissivity of the specimen, and rotation of the specimen to acquire multiple projections covering the 3D spatial frequency domain. Two types of rotational scanning are possible: tomographic and laminographic. For flat, extended samples, for which the full 180° coverage is not possible, the latter is preferable because it provides better coverage of the 3D spatial frequency domain compared to limited-angle tomography. It is also because the amount of attenuation through the sample is approximately the same for all projections. However, both techniques are time consuming because of extensive acquisition and computation time. Here, we demonstrate the acceleration of ptycho-laminographic reconstruction of integrated circuits with 16 times fewer angular samples and 4.67 times faster computation by using a physics-regularized deep self-supervised learning architecture. We check the fidelity of our reconstruction against a densely sampled reconstruction that uses full scanning and no learning. As already reported elsewhere [ Opt. Express 28 , 12872 ( 2020 ) OPEXFF 1094-4087 10.1364/OE.379200 ], we observe improvement of reconstruction quality even over the densely sampled reconstruction, due to the ability of the self-supervised learning kernel to fill the missing cone.

47 OTHER INSTRUMENTATION↗

Attentional Ptycho-Tomography (APT) for three-dimensional nanoscale X-ray imaging with minimal data acquisition and computation time

Abstract Noninvasive X-ray imaging of nanoscale three-dimensional objects, such as integrated circuits (ICs), generally requires two types of scanning: ptychographic, which is translational and returns estimates of the complex electromagnetic field through the IC; combined with a tomographic scan, which collects these complex field projections from multiple angles. Here, we present Attentional Ptycho-Tomography (APT), an approach to drastically reduce the amount of angular scanning, and thus the total acquisition time. APT is machine learning-based, utilizing axial self-Attention for Ptycho-Tomographic reconstruction. APT is trained to obtain accurate reconstructions of the ICs, despite the incompleteness of the measurements. The training process includes regularizing priors in the form of typical patterns found in IC interiors, and the physics of X-ray propagation through the IC. We show that APT with ×12 reduced angles achieves fidelity comparable to the gold standard Simultaneous Algebraic Reconstruction Technique (SART) with the original set of angles. When using the same set of reduced angles, then APT also outperforms Filtered Back Projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT) and SART. The time needed to compute the reconstruction is also reduced, because the trained neural network is a forward operation, unlike the iterative nature of these alternatives. Our experiments show that, without loss in quality, for a 4.48 × 93.2 × 3.92 µm 3 IC (≃6 × 10 8 voxels), APT reduces the total data acquisition and computation time from 67.96 h to 38 min. We expect our physics-assisted and attention-utilizing machine learning framework to be applicable to other branches of nanoscale imaging, including materials science and biological imaging.

47 OTHER INSTRUMENTATION↗

Three-dimensional nanoscale reduced-angle ptycho-tomographic imaging with deep learning (RAPID)

X-ray ptychographic tomography is a nondestructive method for three dimensional (3D) imaging with nanometer-sized resolvable features. The size of the volume that can be imaged is almost arbitrary, limited only by the penetration depth and the available scanning time. Here we present a method that rapidly accelerates the imaging operation over a given volume through acquiring a limited set of data via large angular reduction and compensating for the resulting ill-posedness through deeply learned priors. The proposed 3D reconstruction method “RAPID” relies initially on a subset of the object measured with the nominal number of required illumination angles and treats the reconstructions from the conventional two-step approach as ground truth. It is then trained to reproduce equal fidelity from much fewer angles. After training, it performs with similar fidelity on the hitherto unexamined portions of the object, previously not shown during training, with a limited set of acquisitions. In our experimental demonstration, the nominal number of angles was 349 and the reduced number of angles was 21, resulting in a x140 aggregate speedup over a volume of 4.48 x 93.18 x 3.92 μm 3 and with (14nm) 3 feature size, i.e. ~ 10 8 voxels. RAPID’s key distinguishing feature over earlier attempts is the incorporation of atrous spatial pyramid pooling modules into the deep neural network framework in an anisotropic way. We found that adjusting the atrous rate improves reconstruction fidelity because it expands the convolutional kernels’ range to match the physics of multi-slice ptychography without significantly increasing the number of parameters.

47 OTHER INSTRUMENTATION↗

High-resolution ptychographic imaging enabled by high-speed multi-pass scanning

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh’s criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic zinc fluxes regulate meiotic progression in Caenorhabditis elegans

Abstract Zinc influx and efflux events are essential for meiotic progression in oocytes of several mammalian and amphibian species, but it is less clear whether this evolutionary conservation of zinc signals is also important in late-stage germline development in invertebrates. Using quantitative, single cell elemental mapping methods, we find that Caenorhabditis elegans oocytes undergo significant stage-dependent fluctuations in total zinc content, rising by over sevenfold from Prophase I through the beginning of mitotic divisions in the embryo. Live imaging of the rapid cell cycle progression in C. elegans enables us to follow changes in labile zinc pools across meiosis and mitosis in single embryo. We find a dynamic increase in labile zinc prior to fertilization that then decreases from Anaphase II through pronuclear fusion and relocalizes to the eggshell. Disruption of these zinc fluxes blocks extrusion of the second polar body, leading to a range of mitotic defects. We conclude that spatial temporal zinc fluxes are necessary for meiotic progression in C. elegans and are a conserved feature of germ cell development in a broad cross section of metazoa.

59 BASIC BIOLOGICAL SCIENCES↗

Achieving high spatial resolution in a large field-of-view using lensless x-ray imaging

X-ray ptychography, a powerful scanning lensless imaging technique, has become attractive for nondestructively imaging internal structures at nanoscale. Stage positioning overhead in conventional step-scan ptychography is one of the limiting factors on the imaging throughput. In this work, we demonstrate the use of advanced fly scan ptychography to achieve high-resolution ptychograms of modern integrated circuits on a large field-of-view at millimeter scale. By completely removing stage overheads between scan points, the imaging time for millimeter-size sample can be significantly reduced. Furthermore, we implement the orthogonal probe relaxation technique to overcome the variation of illumination across the large scan area as well as local vibrations. The capability of x-ray ptychography shown here is broadly applicable for various studies, which requires both high spatial resolution and large scan area.

47 OTHER INSTRUMENTATION↗