Engineering Papers⌕ Search

Engineering topics

Viehmann, W.

Publications and source records attributed to Viehmann, W..

At least 19 records

Ultraviolet and visible BRDF data on spacecraft thermal control and optical baffle materials

Bidirectional scattering functions of numerous optical baffle materials and of spacecraft thermal control coatings and surfaces are presented. Measurements were made at 254 nm and at 633 nm. The coatings and surfaces include high-reflectance white paints, low-reflectance optical blacks, thermal control blankets, and various conversion coatings on aluminum.

Viehmann, W.↗

Channel waveguides in glass via silver-sodium field-assisted ion exchange

Multimode channel waveguides have been formed in sodium aluminosilicate glass by field-assisted diffusion of Ag(+) ions from vacuum-evaporated Ag films. The two-dimensional refractive index profiles of the waveguides were controlled by varying the diffusion time, the diffusion temperature, and the electric field strength. Estimates of the diffusion rate through a strip aperture were obtained, assuming the electric field was strong 120-240 V/mm. The maximum change in refractive index in the sodium aluminosilicate glasses was estimated near 65 percent of the change in soda-lime silicate glass. The physical properties of the glasses are given in a table.

Forrest, K.↗

Quantum efficiency measurements for several waveshifter coatings in the extreme vacuum ultraviolet

Quantum efficiency measurements are given for coronene and liumogen coatings designed to enhance UV sensitivity for silicon charge coupled device imaging detectors. Coatings on quartz and on UDT PIN 10DP photodiodes were tested. The wavelength range extended from 153.7 to 50.0 nm in the vacuum ultraviolet. Similar measurements were made for coronene, liumogen, and stilbene-3 laser dye films on quartz disks relative to sodium salicylate. Sodium salicylate and coronene are the most efficient waveshifters down to 50 nm so far observed. Coronene's fairly constant quantum efficiency over such a wide wavelength range into the far VUV makes it a useful waveshifter for UV and VUV applications.

Butner, C. L.↗

Evaluation of GOES encoder lamps

Aging characteristics and life expectancies of flight quality, tungsten filament, encoder lamps are similar to those of 'commercial' grade gas filled lamps of similar construction, filament material and filament temperature. The aging and final failure by filament burnout are caused by single crystal growth over large portions of the filament with the concomitant development of facets and notches resulting in reduction of cross section and mechanical weakening of the filament. The life expectancy of presently produced lamps is about one year at their nominal operating voltage of five volts dc. At 4.5 volts, it is about two years. These life times are considerably shorter, and the degradation rates of lamp current and light flux are considerably higher, than were observed in the laboratory and in orbit on lamps of the same type manufactured more than a decade ago. It is speculated that the filaments of these earlier lamps contained a crystallization retarding dopant, possibly thorium oxide. To obtain the desired life expectancy of or = to four years in present lamps, operating voltages of or = to four volts dc would be required.

Viehmann, W.↗

Fluorescent radiation converter

A fluorescence radiation converter is described which includes a substantially undoped optically transparent substrate and a waveshifter coating deposited on at least one portion of the substrate for absorption of radiation and conversion of fluorescent radiation. The coating is formed to substantially 1000 g/liter of a solvent, 70 to 200 g/liter of an organic polymer, and 0.2 to 25 g/liter of at least one organic fluorescent dye. The incoming incident radiation impinges on the coating. Radiation is absorbed by the fluorescent dye and is re-emitted as a longer wavelength radiation. Radiation is trapped within the substrate and is totally internally reflected by the boundary surface. Emitted radiation leaves the substrate ends to be detected.

Viehmann, W.↗

Ultraviolet /UV/ sensitive phosphors for silicon imaging detectors

The fluorescence properties of UV sensitive organic phosphors and the radiometric properties of phosphor coated silicon detectors in the VUV, UV, and visible wavelengths are described. With evaporated films of coronene and liumogen, effective quantum efficiencies of up to 20% have been achieved on silicon photodiodes in the vacuum UV. With thin films of methylmethacrylate (acrylic), which are doped with organic laser dyes and deposited from solution, detector quantum efficiencies of the order of 15% for wavelengths of 120-165 nm and of 40% for wavelengths above 190 nm have been obtained. The phosphor coatings also act as antireflection coatings and thereby enhance the response of coated devices throughout the visible and near IR.

Viehmann, W.↗

Fluorescent radiation converter

Fluorescent radiation converter used optically transparent substrate. One side of substrate is coated with plastic film containing fluorescent organic dyes that absorb optical radiation at one wavelength and emit it at longer one. Coating is formulated to respond to specific wavelengths. Emitted radiation is reflected internally inside substrate, amplifying intensity that reaches radiation detector. Converter can be made in several shapes and size; round and square bars coated all round their lengths are useful in converting relatively intense radiation and transmitting it through substrate over lengthy distances.

Viehmann, W.↗

Thin-film scintillators for extended ultraviolet /UV/ response silicon detectors

The preparation and radiometric properties of silicon detectors coated with fluorescent thin films are described. The films are deposited from solutions of clear plastics, such as acrylic resins, polyvinyl toluene or polystyrene, and of organic laser dyes in a common solvent. They are optically clear, mechanically and chemically stable, yet easily applied and removed. Multiple doped films of a few microns thickness exhibit broad-band absorption from less than 250 nm to about 450 nm and narrow band emissions with peaks ranging from 380 nm to 600 nm. Internal quantum efficiencies are close to 100 percent and fluorescence decay times are in the nanosecond range. When deposited on optically denser media, a large fraction of the fluorescent emission is trapped in the substrate. Silicon photodiodes coated with multiple doped films exhibit high external quantum efficiencies and virtually flat photon response in the near UV.

Viehmann, W.↗

Investigation of conductive thermal control coatings by a contactless method in vacuo

A technique for determining the conductance per unit area of thermal control coatings for electrostatically clean spacecraft is described. In order to simulate orbital conditions more closely, current-density-voltage (j-V) curves are obtained by a contactless method in which the paint on an aluminum substrate is the anode of a vacuum diode configuration with a tungsten filament cathode. Conductances per unit area which satisfy the International Sun Earth Explorer (ISEE) requirement were observed on black paints containing carbon and in white and green paints filled with zinc oxide which were fired in order to induce defect conductivity. Because of surface effects and the nonhomogeneous nature of paints, large discrepancies were found between measurements with the contactless method and measurements employing metallic contacts, particularly at low current densities. Therefore, measurements with metallic contacts are considered to be of questionable value in deciding the suitability of coatings for electrostatic charge control.

Viehmann, W.↗

Noise limitations of multiplier phototubes in the radiation environment of space

The contributions of Cerenkov emission, luminescence, secondary electron emission, and bremsstrahlung to radiation-induced data current and noise of multiplier phototubes were analyzed quantitatively. Fluorescence and Cerenkov emission in the tube window are the major contributors and can quantitatively account for dark count levels observed in orbit. Radiation-induced noise can be minimized by shielding, tube selection, and mode of operation. Optical decoupling of windows and cathode (side-window tubes) leads to further reduction of radiation-induced dark counts, as does reducing the window thickness and effective cathode area, and selection of window/cathode combinations of low fluorescence efficiency. In trapped radiation-free regions of near-earth orbits and in free space, Cerenkov emission by relativistic particles contributes predominantly to the photoelectron yield per event. Operating multiplier phototubes in the photon (pulse) counting mode will discriminate against these large pulses and substantially reduce the dark count and noise to levels determined by fluorescence.

Viehmann, W.↗

Photomultiplier window materials under electron irradiation - Fluorescence and phosphorescence

The fluorescence and phosphorescence of photomultiplier window materials under electron irradiation have been investigated using a Sr-90/Y-90 beta emitter as the electron source. Spectral emission curves of UV-grade, optical-grade, and electron-irradiated samples of MgF2 and LiF, and of CaF2, BaF2, sapphire, fused silica, and UV-transmitting glasses were obtained over the 200-650-nm spectral range. Fluorescence yields were determined on these materials utilizing photomultiplier tubes with cesium telluride, bialkali, and trialkali (S-20) photocathodes, respectively. Optical-grade MgF2 and LiF, as well as electron-irradiated UV-grade samples of these two materials, show enhanced fluorescence due to color-center formation and associated emission bands in the blue and red wavelength regions. Large variations in fluorescence intensities were found in UV-grade sapphire samples of different origins, particularly in the red end of the spectrum, presumably due to various amounts of chromium-ion content. Phosphorescence decay with time is best described by a sum of exponential terms, with time constants ranging from a few minutes to several days.

Viehmann, W.↗

Fluorescence and phosphorescence of photomultiplier window materials under electron irradiation

The fluorescence and phosphorescence of photomultiplier window materials under electron irradiation were investigated using a Sr-90/Y-90 beta emitter as the electron source. Spectral emission curves of UV grade, optical grade, and electron-irradiated samples of MGF2 and LiF, CaF2, BaF2, sapphire, fused silica, and UV transmitting glasses were obtained over the spectral range of 200 nm to 650 nm. Fluorescence yields, expressed as the number of counts in a solid angle of 2 pi steradian per 1MeV of incident electron energy deposited, were determined on these materials utilizing photomultiplier tubes with cesium telluride, bialkali, and trialkali (S-20) photocathodes, respectively.

Viehmann, W.↗

Instrumental and analytic techniques for separating protons from electrons in the cosmic ray flux

Techniques are being investigated to aid in distinguishing between electrons and the large background of interacting protons which simulate electron-induced electromagnetic cascades. For cosmic ray primaries, incident on the HECRE ionization spectrometer, statistical criteria are employed to test the cascade curves with the incident energy and starting point as free parameters. The physical significance of the distribution of apparent cascade starting points is being studied using Monte Carlo 100-GeV protons. The proposed use of a CsI detector module (totally-active and high Z) to further discriminate against protons is described.

Crannell, C. J.↗

Characteristics of cesium iodide for use as a particle discriminator for high energy cosmic rays

The possible use of CsI to discriminate between high energy cosmic ray electrons and interacting protons has been investigated. The pulse-shape properties as a function of ionization density, temperature, and spectral response are presented for thallium-activated CsI and as a function of ionization density for sodium-activated CsI. The results are based on previously published data and on corroborative measurements from the present work. Experimental results on the response of CsI to electron-induced electromagnetic cascades and to interacting hadrons are described. Bibliographies of publications dealing with the properties of CsI and with pulse-shape discrimination techniques are presented.

Crannell, C. J.↗

Optical transmission measurements on monocrystalline and polycrystalline cesium iodide

A summary is presented of optical measurements performed on a variety of cesium iodide samples to characterize quantitatively the optical quality of the materials, and to define and measure parameters which determine its suitability as a detector material for high energy cosmic ray experiments on HEAO-A. The general case of light transmission through a long rectangular slab under multiple internal reflections is discussed along with transmission and scattering as a function of wavelength at normal incidence. Scattering parameters are tabulated for encapsulated single crystal CsI and polyscin.

Viehmann, W.↗

Effects of surface contamination on the infrared emissivity and visible-light scattering of highly reflective surfaces at cryogenic temperatures

A technique is described for the simultaneous in situ measurement of film thickness, refractive index, total normal emissivity, visible-light scattering, and reflectance of contaminant films on a highly reflective liquid-nitrogen cooled, stainless steel substrate. Emissivities and scattering data are obtained for films of water, carbon dioxide, silicone oil, and a number of aromatic and aliphatic hydrocarbons as a function of film thickness between zero and 20 microns. Of the contaminants investigated, water has by far the greatest effect on emissivity, followed by silicone oil, aliphatic hydrocarbons, aromatic hydrocarbons, and carbon dioxide. The emissivity increases more rapidly with film thickness between zero and 2.5 microns than at thicknesses greater than 2.5 microns. Scattering of visible light changes very little below 2 microns thickness but increases rapidly with thickness beyond 2 to 3 microns. The effect of contaminant films on passive radiation coolers is discussed.

Viehmann, W.↗

Effects of surface contamination on the infrared emissivity and visible-light scattering of highly reflective surfaces at cryogenic temperatures

A technique is described for the simultaneous in situ measurement of film thickness, refractive index, total normal emissivity, visible light scattering, and reflectance of contaminant films on a highly reflective liquid nitrogen-cooled, stainless steel substrate. Emissivities and scattering data were obtained for films of water, carbon dioxide, silicone oil, and a number of aromatic and aliphatic hydrocarbons as a function of film thickness between zero and 20 microns. Water had the greatest effect on emissivity, followed by silicone oil, aliphatic hydrocarbons, aromatic hydrocarbons, and carbon dioxide. Emissivity increased more rapidly with film thickness between zero and 2.5 microns, than at thickness greater than 2.5 microns. Scattering of visible light changed little below 2-microns thickness but increased rapidly with thickness beyond 2 to 3 microns. The effect of contaminant films on passive radiation coolers is discussed.

Viehmann, W.↗