Engineering Papers⌕ Search

Engineering topics

Vessot, Robert F. C.

Publications and source records attributed to Vessot, Robert F. C..

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The cryogenic hydrogen maser (CHM) developed at the Smithsonian Astrophysical Observatory (SAO) was designed to be functionally similar to SAO room temperature hydrogen masers with appropriate modifications made for operation at cryogenic temperatures. A schematic of the SAO CHM is shown in Figure 1, and a description of this device and its operation follows. A beam of molecular hydrogen is dissociated into atoms at room temperature. The resultant beam of atomic hydrogen is then cooled, magnetically state selected, and focused into a quartz storage bulb centered inside of a microwave cavity resonant with the hydrogen hyperfine transition at 1420 MHz. The quartz storage bulb is coated with a superfluid He-4 film, and both the bulb and cavity are maintained near 0.5 K. The maser signal is coupled out inductively and carried to room temperature via semi-rigid coaxial cable. After passing through a room temperature isolator and preamp, the maser signal is detected with a low-noise heterodyne receiver as used in the room temperature SAO hydrogen masers. The maser temperature is lowered to 0.5 K using a recirculating He-3 refrigerator. This refrigerator consists of several cooling stages: a liquid nitrogen stage at 77 K, a liquid 4He bath at 4.2 K, a pumped He-4 pot at approximately 1.7 K, and the pumped, recirculating He-3 stage at 0.5 K. The atomic hydrogen beam, state selector, storage bulb and cavity are all connected inside a single, maser vacuum chamber (MVC). This space is pumped out from below by a turbo pump. Above the MVC, an inlet to the space allows for the input of flowing superfluid 4He film. External to the MVC is a second, outer vacuum chamber (OVC), maintained for operation of the cryostat and also pumped by a turbo pump. Inside the OVC, there is radiation shielding at 77 K and 1.7 K.

Walsworth, Ronald L.↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.↗

Hydrogen Maser Clock (HMC) Experiment

The Hydrogen Maser Clock (HMC) project was originally conceived to fly on a reflight of the European Space Agency (ESA) free flying platform, the European Recoverable Carrier (EURECA) that had been launched into space and recovered by NASA's Space Transportation System (STS). A Phase B study for operation of HMC as one of the twelve EURECA payload components was begun in July 1991, and completed a year later. Phase C/D of HMC began in August 1992 and continued into early 1995. At that time ESA decided not to refly EURECA, leaving HMC without access to space. Approximately 80% of the flight support electronics are presently operating the HMC's physics package in a vacuum tank at the Smithsonian Astrophysical Observatory, and are now considered to be well-tested flight electronics. The package will continue to be operated until the end of 1997 or until a flight opportunity becomes avaiable. Appendices: letters and trip report; proceedings of the symposium on frequency standards and metrology; milli-celsius-stability thermal control for an orbiting frequency standard.

Vessot, Robert F. C.↗

High Precision Time Transfer in Space with a Hydrogen Maser on MIR

An atomic hydrogen maser clock system designed for long term operation in space will be installed on the Russian space station Mir, in late 1997. The H-maser's frequency stability will be measured using pulsed laser time transfer techniques. Daily time comparisons made with a precision of better than 100 picoseconds will allow an assessment of the long term stability of the space maser at a level on the order of 1 part in 10(sup 15) or better. Laser pulse arrival times at the spacecraft will be recorded with a resolution of 10 picoseconds relative to the space clock's time scale. Cube corner reflectors will reflect the pulses back to the Earth laser station to determine the propagation delay and enable comparison with the Earth-based time scale. Data for relativistic and gravitational frequency corrections will be obtained from a Global Positioning System (GPS) receiver.

Mattison, Edward M.↗

Test of an orbiting hydrogen maser clock system using laser time transfer

We describe a joint Smithsonian Astrophysical Laboratory/National Aeronautics and Space Administration (SAO/NASA) program for flight testing a atomic hydrogen maser clock system designed for long-term operation in space. The clock system will be carried by a shuttle-launched EURECA spacecraft. Comparisons with earth clocks to measure the clock's long-term frequency stability (tau = 10(exp 4) seconds) will be made using laser time transfer from existing NASA laser tracking stations. We describe the design of the maser clock and its control systems, and the laser timing technique. We describe the precision of station time synchronization and the limitations in the comparison between the earth and space time scales owing to gravitational and relativistic effects. We will explore the implications of determining the spacecraft's location by an on-board Global Position System (GPS) receiver, and of using microwave techniques for time and frequency transfer.

Vessot, Robert F. C.↗

Complete the development and construction of a spaceborne hydrogen maser clock

The objective, to complete the development of an engineering model of a spaceborne hydrogen maser, was successfully achieved. A layout of the maser and detail drawings of the physics package was completed during the first 7 months of the contract. A computer model was made for the maser's thermal design. Using numerical computations, heater resistances were established for 7 temperature controlled zones. The physics package includes: a vacuum manifold that houses four sorption pumps capable of scavenging hydrogen for 4 years, a titanium vacuum tank housing the cavity, metallic seals for all vacuum joints, an RF dissociator within the vacuum envelope, a two-layer printed circuit solenoid and four layers of moly-permalloy magnetic shields. Problems were encountered and overcome in the procurements of the PC solenoid and the magnetic shields. After completion of the fabrication of the maser's components, the maser was assembled using these parts and other components made available by SAO, NRL, and NASA from earlier development work. In March, 1990, the vacuum system was assembled, and by May the maser assembly was completed. The magnetic shielding was poor and the shields were removed, reannealed by a local vendor, and the maser was reassembled. The maser began tests in early June and has been oscillating since that time. The test results of the maser are very good and a life test of the maser is being conducted. It is anticipated that the development and construction of a maser to be tested in space under a new contract from NASA's Marshall Space Flight Center will continue.

Vessot, Robert F. C.↗

State of the art and future directions for the atomic hydrogen maser

The present status of technology development for atomic hydrogen masers (H-masers) is reviewed. The limitations to frequency stability and accuracy are discussed with emphasis on the problems associated with cavity resonator instability and the lack of reproducibility and stability of the storage volume wall coating frequency shift. New types of coating developed in the Soviet Union and better, cavity resonator materials, are expected to make possible frequency at the 10(exp -16) level at 10(exp 4) sec. Better control of systematic effects should extend the long-term stability to levels better than 10(exp -15) for intervals beyond one day. Present use of H-masers as flywheel oscillators in timekeeping systems is discussed as is the outlook for the future cryogenic and room temperature H-masers as flywheel oscillators to operate very high resolution frequency discriminators based on the newly evolving technology of trapped and cooled ions and atoms.

Vessot, Robert F. C.↗

Effect of thermal cycling on stress in metallic films on ceramic substrates

The hydrogen maser is the most stable frequency standard currently available for averaging intervals of hours to weeks. A major contributor to maser frequency variations is the maser's microwave resonant cavity: by means of the cavity pulling effect, a change in the cavity's resonance frequency produces a proportional change in the maser's output frequency. To minimize variations in the cavity's dimensions, and thus in its resonance frequency, maser cavities are often constructed of a low-expansivity glass-ceramic material coated on its surface with a conductive metallic film. It was previously shown that silver films like those used in SAO maser cavities develop tensile stress when cooled to room temperature after being fired onto the cavity, and that the stress in such films relaxes with time at a rate proportional to the level of stress. Stress relaxation in maser cavity coatings can alter the shape, and hence the resonance frequency, of the cavity, resulting in a slow variation in the maser's output frequency. The possibility was investigated of reversing the initial tensile stress by precooling the coated cavity material. It was hypothesized that cooling the material well below its normal working temperature and then warming it to its normal temperature would result in a lower tensile stress or even a compressive stress. Under such a condition stress relaxation, and thus any consequent frequency drifts, might be reduced or reversed.

Mattison, Edward M.↗

Performance of Soviet and US hydrogen masers

The frequencies of Soviet- and U.S.-built hydrogen masers located at the Smithsonian Astrophysical Observatory and at the United States Naval Observatory (USNO) were compared with each other and, via Global Positioning System (GPS) common-view measurements, with three primary frequency-reference scales. The best masers were found to have fractional frequency stabilities as low as 6 times 10(exp -16) for averaging times of approximately 10(exp 4) s. Members of the USNO maser ensemble provided frequency prediction better than 1 times 10(exp 14) for periods up to a few weeks. The frequency residuals of these masers, after removal of frequency drift and rate of change of drift, had stabilities of a few parts in 10(exp -15), with serveral masers achieving residual stabilities well below 1 times 10(exp -15) for intervals from 10(exp 5)s to 2 times 10(exp 6)s. The fractional frequency drifts of the 13 masers studied, relative to the primary reference standards, ranged from -0.2 times 10(exp -15)/day to +9.6 times 10(exp -15)/day.

Uljanov, Adolph A.↗

A review of atomic clock technology, the performance capability of present spaceborne and terrestrial atomic clocks, and a look toward the future

Clocks have played a strong role in the development of general relativity. The concept of the proper clock is presently best realized by atomic clocks, whose development as precision instruments has evolved very rapidly in the last decades. To put a historical prospective on this progress since the year AD 1000, the time stability of various clocks expressed in terms of seconds of time error over one day of operation is shown. This stability of operation must not be confused with accuracy. Stability refers to the constancy of a clock operation as compared to that of some other clocks that serve as time references. Accuracy, on the other hand, is the ability to reproduce a previously defined frequency. The issues are outlined that must be considered when accuracy and stability of clocks and oscillators are studied. In general, the most widely used resonances result from the hyperfine interaction of the nuclear magnetic dipole moment and that of the outermost electron, which is characteristic of hydrogen and the alkali atoms. During the past decade hyperfine resonances of ions have also been used. The principal reason for both the accuracy and the stability of atomic clocks is the ability of obtaining very narrow hyperfine transition resonances by isolating the atom in some way so that only the applied stimulating microwave magnetic field is a significant source of perturbation. It is also important to make resonance transitions among hyperfine magnetic sublevels where separation is independent, at least to first order, of the magnetic field. In the case of ions stored in traps operating at high magnetic fields, one selects the trapping field to be consistent with a field-independent transition of the trapped atoms.

Vessot, Robert F. C.↗

Improved State Selection For Hydrogen Masers

Improved selection system for hydrogen maser helps exclude hydrogen atoms from storage bulb in undesired quantum states not contributing to amplification/oscillation process. Atoms in undesired states limit stability of maser by reducing storage lifetime of atoms in desired state, reducing output power, and colliding with atoms in desired state under circumstances that causing systematic shifts in frequency.

Vessot, Robert F. C.↗

Single-state selection system for hydrogen masers

The design and operation of a single-state selection system based on the adiabatic fast-passage technique for atomic state inversion is described. The system uses a variable-pitch dc solenoid and orthogonal four-wire RF coil to create the state-changing magnetic fields, and a half-wavelength state selection magnet to remove the inverted state atoms from the hydrogen beam. The system's performance was determined by measuring maser power as a function of line Q. The system removes more than 85 percent of undesired atoms from the beam. The potential effects of improvements in the maser on its frequency stability have been calculated. The use of single-state selection combined with increased RF coupling to the cavity and increased storage bulb collimation offers the possibility of frequency stability in the 10 to the -17th regime over intervals on the order of 60,000 s.

Mattison, Edward M.↗

Coating a Hydrogen-Maser Chamber With CF4

Coating of carbon tetrafluoride formed on interior surface of atomic-hydrogen maser by allowing gas to freeze on surface. New coating enables maser to oscillate down to 26 K; most effective previous coating, fluorinated ethylene/polypropylene (FEP) copolymer allowed oscillation down to about 50 K.

Vessot, Robert F. C.↗