Measuring roughness of buried interfaces by sputter depth profiling
Abstract not provided
Engineering topics
Publications and source records attributed to Veryovkin, I V.
Abstract not provided
Abstract not provided
White light interferometry (WLI) can be used to obtain surface morphology information on dimensional scale of millimeters with lateral resolution as good as {approx}1 {micro}m and depth resolution down to 1 nm. By performing true three-dimensional imaging of sample surfaces, the WLI technique enables accurate quantitative characterization of the geometry of surface features and compares favorably to scanning electron and atomic force microscopies by avoiding some of their drawbacks. In this paper, results of using the WLI imaging technique to characterize the products of ion sputtering experiments are reported. With a few figures, several example applications of the WLI method are illustrated when used for (i) sputtering yield measurements and time-to-depth conversion, (ii) optimizing ion beam current density profiles, the shapes of sputtered craters, and multiple ion beam superposition and (iii) quantitative characterization of surfaces processed with ions. In particular, for sputter depth profiling experiments of {sup 25}Mg, {sup 44}Ca and {sup 53}Cr ion implants in Si (implantation energy of 1 keV per nucleon), the depth calibration of the measured depth profile curves determined by the WLI method appeared to be self-consistent with TRIM simulations for such projectile-matrix systems. In addition, high depth resolution of the WLI method is demonstrated for a case of a Genesis solar wind Si collector surface processed by gas cluster ion beam: a 12.5 nm layer was removed from the processed surface, while the transition length between the processed and untreated areas was 150 {micro}m.
The Large-Area Picosecond Photo-Detector Project is focused on the development of large-area systems to measure the time-of-arrival of relativistic particles with, ultimately, 1 pico-second resolution, and for signals typical of Positron-Emission Tomography (PET), a resolution of about 30 pico-seconds. Our contribution to this project is to help with identification and efficient fabrication of novel electron emitting materials with properties optimized for use in such detectors. We have assembled several techniques into a single ultra-high vacuum apparatus in order to enable characterization of both photocathode and secondary electron emission (SEE) materials. This apparatus will examine how photocathode quantum efficiency and SEE material electron yield correlate to surface chemical composition, state, and band structure. The techniques employed in this undertaking are X-ray photoelectron spectroscopy (XPS) for surface chemical composition, ultraviolet photoelectron spectroscopy (UPS) for the determination of band structure and surface work function, as well surface cleaning techniques such as argon-ion sputtering. To determine secondary electron emission yields and quantum efficiencies of detector materials, we use electron optics from a low energy electron diffraction (LEED) system whose set of hemispherical electrodes allows for efficient collection of secondary and photo electrons. As we gain a stronger insight into the details of mechanisms of electron emission from photocathodes and SEE materials, we will be able to lay a foundation for the larger collaborative effort to design the next generation of large-area photo-detectors. We present our preliminary results on the SEE materials from our as-yet completed characterization system.
RIMS depth profiles have been measured for Cr and Ca in Genesis solar wind collector made from Si and compared to such measurements for ion-implanted Si reference material. The presence of surface contamination has been shown to be a significant factor influencing the total Ca and Cr fluence measured in the Genesis collectors. A procedure to remove the contaminant signal from these depth profiles using the reference material implanted with a minor isotope demonstrated that 36% of the measured Ca fluence in our Genesis sample comes from terrestrial contamination.
There are four generally mutually exclusive requirements that plague many mass spectrometric measurements of trace constituents: (1) the small size (limited by the depth probed) of many interesting materials requires high useful yields to simply detect some trace elements, (2) the low concentrations of interesting elements require efficient discrimination from isobaric interferences, (3) it is often necessary to measure the depth distribution of elements with high surface and low bulk contributions, and (4) many applications require precise isotopic analysis. Resonant ionization mass spectrometry has made dramatic progress in addressing these difficulties over the past five years.
Laser-Induced Acoustic Desorption (LIAD) from thin metal foils is a promising technique for gentle and efficient volatilization of intact organic molecules from surfaces of solid substrates. Using the Single Photon Ionization (SPI) method combined with time-of-flight mass-spectrometry (TOF MS), desorbed flux in LIAD was examined and compared to that from direct laser desorption (LD). Molecules of various organic dyes were used in experiments. Translational velocities of the desorbed intact molecules did not depend on the desorbing laser intensity, which implies the presence of more sophisticated mechanism of energy transfer than the direct mechanical or thermal coupling between the laser pulse and the adsorbed molecules. The results of our experiments indicate that the LIAD phenomenon cannot be described in terms of a simple mechanical shake-off nor the direct laser desorption. Rather, they suggest that multi-step energy transfer processes are involved. Possible qualitative mechanism of LIAD that are based on formation of non-equilibrium energy states in the adsorbate-substrate system are proposed and discussed.
Polycrystalline Au was bombarded with 15 keV Ar{sup +}, and the resulting secondary neutral cluster yield distribution was measured by laser postionisation mass spectrometry. Neutral Au{sub n} clusters containing up to 20 atoms were observed. The yield of Au{sub n} clusters, Y{sub n}, was found to follow a power in n, Y{sub n} {infinity} n{sup -3.4}, but the yield of individual clusters depended on whether n was even or odd. This odd-even yield variation was caused by fragmentation of the cluster photoions. Simulation of photoion trajectories within the TOF spectrometer shows that the fragmentation dominantly occurs before the photoions enter the reflectron part of the spectrometer.
Polycrystalline Ag, Ag{sub 20}Au{sub 80}, Ag{sub 40}Au{sub 60}, Ag{sub 80}Au{sub 20} and Au samples were bombarded with 15 keV Ar{sup +} at 60{sup o} incidence and the resulting secondary neutral yield distribution was studied by non-resonant laser post-ionization mass spectrometry. Neutral clusters containing up to 21 atoms were observed for the targets. The yield of neutral clusters, Ag{sub m}Au{sub n-m}, containing n atoms, Y{sub n}, was found to follow a power in n, i.e. Y{sub n} {proportional_to} n{sup -{delta}}, where the exponent {delta} varied from 3.2 to 4.0. For a fixed n, the cluster yields showed a variation with number of gold atoms similar to that expected for a binomial distribution. In addition, the cluster compositions from the sputtered alloys were indicative of sputtering from a gold rich surface.
Polycrystalline Cu, Cu{sub 20}Au{sub 80}, Cu{sub 40}Au{sub 60}, Cu{sub 80}Au{sub 20} and Au samples were bombarded with 15 keV Ar{sup +}, and the resulting secondary neutral yield distribution was studied by non-resonant laser post-ionisation mass spectrometry. Neutral clusters containing up to 15 atoms were observed for the targets. The yield of neutral clusters, Cu{sub m}Au{sub n-m}, containing n atoms, Y{sub n}, was found to follow a power in n, i.e. Y{sub n} {proportional_to} n{sup -{delta}}, where the exponent {delta} varied from 5.2 to 10.1. For a fixed n, the cluster yields showed a variation with number of copper atoms, m, much greater than expected for a binomial distribution suggesting that the clusters are not formed randomly above the surface and a component of preformed cluster emission occurs. In addition, the cluster compositions from the sputtered alloys were indicative of sputtering from a copper rich surface.
A new ion optics system was developed and experimentally tested, which allows for high-resolution multiple beam characterization of materials. This system enables: (1) efficient, quasi-simultaneous measurements of the mass spectra of laser post-ionized sputtered species and secondary ions as well as secondary electron imaging, that can be accompanied and assisted by (2) low energy ion milling and (3) in-situ optical imaging and laser desorption with submicron resolution. Altogether, this ion optics system provides a versatile, sensitive combination of an analytical mass spectrometer and ion, electron and optical microscopes, which can efficiently detect one out of four sample atoms consumed during the analysis.
Laser-induced acoustic desorption (LIAD) from thin metal foils is a promising technique for gentle and efficient volatilization of intact organic molecules from surfaces of solid substrates. Using the single-photon ionization method combined with time-of-flight mass spectrometry, we have examined the neutral component of the desorbed flux in LIAD and compared it to that from direct laser desorption. These basic studies of LIAD, conducted for molecules of various organic dyes (rhodamine B, fluorescein, anthracene, coumarin, BBQ), have demonstrated detection of intact parent molecules of the analyte even at its surface concentrations corresponding to a submonolayer coating. In some cases (rhodamine B, fluorescein, BBQ), the parent molecular ion peak was accompanied by a few fragmentation peaks of comparable intensity, whereas for others, only peaks corresponding to intact parent molecules were detected. At all measured desorbing laser intensities (from 100 to 500 MW/cm{sup 2}), the total amount of desorbed parent molecules depended exponentially on the laser intensity. Translational velocities of the desorbed intact molecules, determined for the first time in this work, were of the order of hundreds of meters per second, less than what has been observed in our experiments for direct laser desorption, but substantially greater than the possible perpendicular velocity of the substrate foil surface due to laser-generated acoustic waves. Moreover, these velocities did not depend on the desorbing laser intensity, which implies the presence of a more sophisticated mechanism of energy transfer than direct mechanical or thermal coupling between the laser pulse and the adsorbed molecules. Also, the total flux of desorbed intact molecules as a function of the total number of desorbing laser pulses, striking the same point on the target, decayed following a power law rather than an exponential function, as would have been predicted by the shake-off model. To summarize, the results of our experiments indicate that the LIAD phenomenon cannot be described in terms of simple mechanical shake-off or direct laser desorption. Rather, they suggest that multistep energy-transfer processes are involved. Two possible (and not mutually exclusive) qualitative mechanisms of LIAD that are based on formation of nonequilibrium energy states in the adsorbate-substrate system are proposed and discussed.