Carotid baroreflex response following 30 days exposure to simulated microgravity
The mechanism of the carotid-baroreflex response to weightlessness was investigated in human subjects exposed to simulated microgravity (30 days of 6-day head-down bed rest followed by 5 days of recovery). Baroreceptor-cardiac reflex responses were elicited by a complex sequence of pressure changes delivered to a neck chamber device. The shape of the sigmoid baroreceptor-cardiac response curve was examined for alterations and the occurrence of resetting, as well as for a possible association of the impaired baroreflex function with hypotension during the postexposure orthostatic stress. It was found that the exposure to head-down bed rest caused a significant shift on the R-R interval axis, which paralleled reductions and elevations in baseline HR such that the baseline R-R (operational point) remained in the same position on the response curve. This shift in the location of the reflex relation indicates a significant resetting of the carotid baroreceptors, which may represent an appropriate adaptation which contributes to the maintenance of a constant resting arterial blood pressure before, during, and after bed rest, observed in these study.