Engineering Papers⌕ Search

Engineering topics

Vermeul, Vince

Publications and source records attributed to Vermeul, Vince.

Using in-situ strain measurements to evaluate the accuracy of stress estimation procedures from fracture injection/shut-in tests

Fracture injection/shut-in tests are commonly used to measure the state of stress. Injection creates a hydraulic fracture (or in some cases, opens a preexisting fracture), and then the pressure after shut-in is monitored to identify fracture closure. Different interpretation procedures have been proposed for estimating closure, and the procedures sometimes yield significantly different results. In this study, direct, in-situ strain measurements are used to observe fracture reopening and closure. The tests were performed as part of the EGS Collab project, a mesoscale project performed at 1.25 and 1.5 km depth at the Sanford Underground Research Facility. The tests were instrumented with the SIMFIP tool, a double-packer probe with a high-resolution three-dimensional borehole displacement sensor. The measurements provide a direct observation of the fracture closure signature, enabling a high-fidelity estimate of the fracture closure stress (ie, the normal stress on the fracture). In two of the four tests, injection created an opening mode fracture, and so the closure stress can be interpreted as the minimum principal stress. In the other two tests, injection probably opened preexisting natural fractures, and so the closure stress can be interpreted as the normal stress on the fractures. The strain measurements are compared against different proposed methods for estimating closure stress from pressure transients. The shut-in transients are analyzed with two techniques that are widely used in the field of petroleum engineering – the ‘tangent’ method and the ‘compliance’ method. In three of the four tests, the tangent method significantly underestimates the closure stress. The compliance method is reasonably accurate in all four tests. Closure stress is also interpreted using two other commonly-used methods – ‘first deviation from linearity’ and the method of Hayashi and Haimson. In comparison with the SIMFIP data, these methods tend to overestimate the closure stress, evidently because they identify closure from early-time transient effects, such as near-wellbore tortuosity. In two of the tests, microseismic imaging provides an independent estimate of the size of the fracture created by injection. When combined with a simple mass balance calculation, the SIMFIP stress measurements yield predictions of fracture size that are reasonably consistent with the estimates from microseismic. In conclusion, the calculations imply an apparent fracture toughness 2-3x higher than typical laboratory-derived values.

58 GEOSCIENCES↗

EGS Collab Experiment 3: 4100 Tensile Stimulation and Thermal Circulation Testing

These data and test descriptions are from a set of primarily tensile hydraulic-fracture stimulations in wells E2-TC and E2-TU and a subsequent chilled water circulation test conducted by injecting in well E2-TU on the 4100 level of the Sandford Underground Research Facility (SURF). Stimulations were carried out between April and May of 2022. The thermal circulation test ran semi-continuously from May 19 through August 26, 2022, though chilled water injection began on June 3. More information about the test, rationale, and processing of data is available on the EGS Collab project page, which is linked below.

15 GEOTHERMAL ENERGY↗

EGS Collab Experiment 2: Results of Tracer Tests

Multiple sets of tracer tests were conducted at the EGS Collab Testbed 2 on the 4100 L at the Sanford Underground Research Facility (SURF), Lead, SD. The enclosed data package includes: tracer recovery results, water balance calculations and rationales, water flow measurement for north ditch, (manual) water flow measurements at different production points, and a tracer-interpretation paper presented at the Stanford Geothermal Workshop, 2023.

15 GEOTHERMAL ENERGY↗

Dissolved oxygen sensor in an automated hyporheic sampling system reveals biogeochemical dynamics

Many river corridor systems frequently experience rapid variations in river stage height, hydraulic head gradients, and residence times. The integrated hydrology and biogeochemistry of such systems is challenging to study, particularly in their associated hyporheic zones. Here we present an automated system to facilitate 4-dimensional study of dynamic hyporheic zones. It is based on combining real-time in-situ and ex-situ measurements from sensor/sampling locations distributed in 3-dimensions. A novel dissolved oxygen (DO) sensor was integrated into the system during a small scale study. We measured several biogeochemical and hydrologic parameters at three subsurface depths in the riverbed of the Columbia River in Washington State, USA, a dynamic hydropeaked river corridor system. During the study, episodes of significant DO variations (~+/- 4 mg/l) were observed, with minor variation in other parameters (e.g., <~+/-0.15 mg/l NO 3 ). DO concentrations were related to hydraulic head gradients, showing both hysteretic and non-hysteretic relationships with abrupt (hours) transitions between the two types of relationships. The observed relationships provide a number of hypotheses related to the integrated hydrology and biogeochemistry of dynamic hyporheic zones. We suggest that preliminary high-frequency monitoring is advantageous in guiding the design of long term monitoring campaigns. The study also demonstrated the importance of measuring multiple parameters in parallel, where the DO sensor provided the key signal for identifying/detecting transient phenomena.

54 ENVIRONMENTAL SCIENCES↗

Time-series dissolved oxygen, other bigeochemically-relevant analytes, and pressure gradients associated with the manuscript “Dissolved oxygen sensor in an automated hyporheic sampling system reveals biogeochemical dynamics”

This dataset contains time-series data from a vertical profile within the bed and banks of the Columbia river near Richland, WA. Water was sampled through 3 small tubes embedded in the sediment at 50,100, and 200 cm below the sediment-water interface. The goal of this study was to observe the correlations between hydraulic drivers and biogeochemical responses. The results of this study are published in the manuscript “Dissolved oxygen sensor in an automated hyporheic sampling system reveals biogeochemical dynamics”. The file types included in the data package are all time-series spreadsheet data, including hydraulic head gradients, physical parameters (temperature, pressure, SpC (specific conductivity)), and biogeochemical parameters (dissolved oxygen, pH, NO3 (nitrate) and ORP (oxidation-reduction potential)).

54 ENVIRONMENTAL SCIENCES↗

EGS Collab Experiment 1 Stimulation Data

Stimulation data from Experiment 1 of EGS Collab, which occurred on the 4850 ft level of the Sanford Underground Research Facility (SURF). A detailed description of the stimulation data is provided in the StimulationDataNotes.docx and is also available on the EGS Collab Wiki. A Meta Data Cheat Sheet, which describes all of the channels in the Raw CSV files, is available as well. Note that this cheat sheet is a comprehensive meta data descriptor and channels were added as the experiment evolved. This means that some columns may not be populated in early data. Additionally, we have included the chat logs from these experiments. The experiments were broadcast over teleconferencing software and real-time data displays were available to remote observers. The logs contain important observations from those personnel performing the experiment and the remote contributors. Finally, we have included summary and individual plots of all of the data for the user to compare to.

15 GEOTHERMAL ENERGY↗

Field Test Bed for Vadose-Zone Monitoring Approaches - 20404

In the Central Plateau at the U.S. Department of Energy Hanford Site, a large inventory of contaminants resides in unsaturated sediments within the approximately 100-meter-thick vadose zone, posing a potential continuing risk to groundwater. Vadose zone remedies used to address these contaminants will require performance monitoring to provide feedback during implementation and for long-term verification that remedial action objectives have been met. Passive approaches may also need long-term monitoring to demonstrate that the flux of contaminants from the vadose zone to the groundwater are below thresholds established to meet groundwater protection goals. Collection of physical (e.g., groundwater or sediment) samples is a common method for identifying contaminant concentration distributions, but this approach is limited by the number of locations and the frequency with which data can be collected. In situ vadose zone measurements have evolved over the past few years to include key measurements of water content, soil water pressure, temperature, and chemical concentration. However, the current generation of sensors is designed for relatively short-term use in near-surface soils or sediments. Geophysical methods have been evolving but are also limited in that they have not been designed for the specific long-term vadose zone monitoring needs at the Hanford Site. Overall, monitoring under unsaturated conditions can be difficult due to the need to install and maintain instrumentation over a large area and depth and the need to identify preferential flow pathways due to geologic and chemical heterogeneities over long periods. Thus, a vadose zone monitoring test bed was initiated to address these challenges and identify cost-effective approaches for implementation and postclosure monitoring of the deep vadose zone. The monitoring test bed is expected to provide valuable field-scale information for the design of vadose zone monitoring systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗