Engineering Papers⌕ Search

Engineering topics

Vercauteren, Tom

Publications and source records attributed to Vercauteren, Tom.

Morphometric Atlas Selection for Automatic Brachial Plexus Segmentation

Purpose: The purpose of this study was to determine the effects of atlas selection based on different morphometric parameters, on the accuracy of automatic brachial plexus (BP) segmentation for radiation therapy planning. The segmentation accuracy was measured by comparing all of the generated automatic segmentations with anatomically validated gold standard atlases developed using cadavers. Methods and Materials: Twelve cadaver computed tomography (CT) atlases (3 males, 9 females; mean age: 73 years) were included in the study. One atlas was selected to serve as a patient, and the other 11 atlases were registered separately onto this “patient” using deformable image registration. This procedure was repeated for every atlas as a patient. Next, the Dice and Jaccard similarity indices and inclusion index were calculated for every registered BP with the original gold standard BP. In parallel, differences in several morphometric parameters that may influence the BP segmentation accuracy were measured for the different atlases. Specific brachial plexus-related CT-visible bony points were used to define the morphometric parameters. Subsequently, correlations between the similarity indices and morphometric parameters were calculated. Results: A clear negative correlation between difference in protraction-retraction distance and the similarity indices was observed (mean Pearson correlation coefficient = −0.546). All of the other investigated Pearson correlation coefficients were weak. Conclusions: Differences in the shoulder protraction-retraction position between the atlas and the patient during planning CT influence the BP autosegmentation accuracy. A greater difference in the protraction-retraction distance between the atlas and the patient reduces the accuracy of the BP automatic segmentation result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Anatomically Validated Brachial Plexus Contouring Method for Intensity Modulated Radiation Therapy Planning

Purpose: To develop contouring guidelines for the brachial plexus (BP) using anatomically validated cadaver datasets. Magnetic resonance imaging (MRI) and computed tomography (CT) were used to obtain detailed visualizations of the BP region, with the goal of achieving maximal inclusion of the actual BP in a small contoured volume while also accommodating for anatomic variations. Methods and Materials: CT and MRI were obtained for 8 cadavers positioned for intensity modulated radiation therapy. 3-dimensional reconstructions of soft tissue (from MRI) and bone (from CT) were combined to create 8 separate enhanced CT project files. Dissection of the corresponding cadavers anatomically validated the reconstructions created. Seven enhanced CT project files were then automatically fitted, separately in different regions, to obtain a single dataset of superimposed BP regions that incorporated anatomic variations. From this dataset, improved BP contouring guidelines were developed. These guidelines were then applied to the 7 original CT project files and also to 1 additional file, left out from the superimposing procedure. The percentage of BP inclusion was compared with the published guidelines. Results: The anatomic validation procedure showed a high level of conformity for the BP regions examined between the 3-dimensional reconstructions generated and the dissected counterparts. Accurate and detailed BP contouring guidelines were developed, which provided corresponding guidance for each level in a clinical dataset. An average margin of 4.7 mm around the anatomically validated BP contour is sufficient to accommodate for anatomic variations. Using the new guidelines, 100% inclusion of the BP was achieved, compared with a mean inclusion of 37.75% when published guidelines were applied. Conclusion: Improved guidelines for BP delineation were developed using combined MRI and CT imaging with validation by anatomic dissection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Deformable Image Coregistration in Adaptive Dose Painting by Numbers for Head-and-Neck Cancer

Purpose: To assess the accuracy of contour deformation and feasibility of dose summation applying deformable image coregistration in adaptive dose painting by numbers (DPBN) for head and neck cancer. Methods and Materials: Data of 12 head-and-neck-cancer patients treated within a Phase I trial on adaptive {sup 18}F-FDG positron emission tomography (PET)-guided DPBN were used. Each patient had two DPBN treatment plans: the initial plan was based on a pretreatment PET/CT scan; the second adapted plan was based on a PET/CT scan acquired after 8 fractions. The median prescription dose to the dose-painted volume was 30 Gy for both DPBN plans. To obtain deformed contours and dose distributions, pretreatment CT was deformed to per-treatment CT using deformable image coregistration. Deformed contours of regions of interest (ROI{sub def}) were visually inspected and, if necessary, adjusted (ROI{sub def{sub ad}}) and both compared with manually redrawn ROIs (ROI{sub m}) using Jaccard (JI) and overlap indices (OI). Dose summation was done on the ROI{sub m}, ROI{sub def{sub ad}}, or their unions with the ROI{sub def}. Results: Almost all deformed ROIs were adjusted. The largest adjustment was made in patients with substantially regressing tumors: ROI{sub def} = 11.8 {+-} 10.9 cm{sup 3} vs. ROI{sub def{sub ad}} = 5.9 {+-} 7.8 cm{sup 3} vs. ROI{sub m} = 7.7 {+-} 7.2 cm{sup 3} (p = 0.57). The swallowing structures were the most frequently adjusted ROIs with the lowest indices for the upper esophageal sphincter: JI = 0.3 (ROI{sub def}) and 0.4 (ROI{sub def{sub ad}}); OI = 0.5 (both ROIs). The mandible needed the least adjustment with the highest indices: JI = 0.8 (both ROIs), OI = 0.9 (ROI{sub def}), and 1.0 (ROI{sub def{sub ad}}). Summed doses differed non-significantly. There was a trend of higher doses in the targets and lower doses in the spinal cord when doses were summed on unions. Conclusion: Visual inspection and adjustment were necessary for most ROIs. Fast automatic ROI propagation followed by user-driven adjustment appears to be more efficient than labor-intensive de novo drawing. Dose summation using deformable image coregistration was feasible. Biological uncertainties of dose summation strategies warrant further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Delineation of the Postprostatectomy Prostate Bed Using Computed Tomography: Interobserver Variability Following the EORTC Delineation Guidelines

Purpose: The present study aims to assess the interobserver agreement of prostate bed delineation after radical prostatectomy using CT alone as proposed by the European Organization for Research and Treatment of Cancer (EORTC) guidelines. Methods and Materials: Six observers delineated the postoperative prostate bed (PB) and the original seminal vesicle position or remnants (SV) of 10 patients according to the EORTC guidelines. Contours were then compared for agreement between observers (the apparent volume overlap and generalized kappa statistics). Standard deviations were also calculated to measure the variability of the position of the outer margins. Results: The mean volume of 100% agreement ({+-}1 standard deviation, SD) was only 5.0 ({+-}3.3) ml for the PB and 0.9 ({+-}1.5) ml for the SV, whereas the mean union of all contours ({+-}1 SD) was 41.1 ({+-}11.8) ml and 25.3 ({+-}13.4) ml, respectively. The mean overall agreement corrected for chance was moderate for both the PB (mean kappa, 0.49; range, 0.35-0.62) and SV (mean kappa, 0.42; range, 0.22-0.59). The overall SD of the outer margins of the PB ranged from 4.6 to 7.0 mm Conclusion: The delineation of the postprostatectomy bed using CT shows only a moderate observer agreement when following the EORTC guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗