We have tested a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC) with waveform digitizing electronics. The prototype's concept is based on the BaBar DIRC with several important improvements: (a) much faster, pixelated photon detectors, (b) a mirror that makes the photon detector smaller and less sensitive to background in future applications, and (c) electronics capable of measuring single photon resolution to {sigma} {approx} 150 ps, which allows for correction due to chromatic error. In this test, the prototype has been instrumented with seven Hamamatsu H-8500 MaPMTs. Waveforms from {approx}450 pixels are digitized with waveform sampling electronics based on the BLAB2 ASIC, operating at a sampling speed of {approx}2.5 GSa/s. This version of the FDIRC prototype was tested in a large cosmic ray telescope providing muon tracks with {approx}1 mrad angular resolution and a muon momentum cutoff of {ge} 1.6 GeV/c.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PID techniques: Alternatives to RICH Methods

In this review article we discuss the recent progress in PID techniques other than the RICH methods. In particular we mention the recent progress in the Transition Radiation Detector (TRD), dE/dx cluster counting, and Time Of Flight (TOF) techniques. The TRD technique is mature and has been tried in many hadron colliders. It needs space though, about 20cm of detector radial space for every factor of 10 in the {pi}/e rejection power, and this tends to make such detectors large. Although the cluster counting technique is an old idea, it was never tried in a real physics experiment. Recently, there are efforts to revive it for the SuperB experiment using He-based gases and waveform digitizing electronics. A factor of almost 2 improvement, compared to the classical dE/dx performance, is possible in principle. However, the complexity of the data analysis will be substantial. The TOF technique is well established, but introduction of new fast MCP-PMT and G-APD detectors creates new possibilities. It seems that resolutions below 20-30ps may be possible at some point in the future with relatively small systems, and perhaps this could be pushed down to 10-15ps with very small systems, assuming that one can solve many systematic issues. However, the cost, rate limitation, aging and cross-talk in multi-anode devices at high BW are problems. There are several groups working on these issues, so progress is likely. Table 6 summarizes the author's opinion of pros and cons of various detectors presented in this paper based on their operational capabilities. We refer the reader to Ref.40 for discussion of other more general limits from the PID point of view.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the Fast Focusing DIRC (fDIRC)

We have built and successfully tested a novel particle identification detector concept, the Fast Focusing DIRC (fDIRC). The prototype's concept is based on the BaBar DIRC with several important improvements: (a) much faster pixelated photon detectors based on Burle MCP-PMTs and Hamamatsu MaPMTs, (b) a focusing mirror allowing a smaller photon detector, reducing the sensitivity to backgrounds in future applications, (c) electronics capable of measuring the single photon resolution to better than {sigma} {approx} 100-200ps. The fDIRC is the first RICH detector to successfully correct the chromatic error by timing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗