Current flow in a plasma caused by dielectric breakdown

Spacecraft with a thin dielectric coating on the outer surface of the structure which are biased (-200 V) negative relative to the atmospheric plasma are susceptible to dielectric breakdown. This paper will present experimental tests designed to measure the electron current flow from the structure through the plasma during the arc. The current path was examined in three parts: the electrons supplied through the structure and the arc to the outer structure, the expansion of the arc into the ambient plasma, and the return current through the ambient plasma. The measured electron current either flowing from the plasma or supplied to the plasma by the arc in each case was compared to the random thermal electron current which could be collected. The results of the tests show a spacecraft is capable of supporting arcs with peak currents greater than thermal electron currents, and these currents will be dependent upon the amount of stored charge in the structure (i.e., the structure's surface area and dielectric thickness). Also, the results of these tests show that it is possible for structures with a self capacitance of 10 microFarads to see peak currents of 90 A and structures with 1000 microFarads (i.e., capacitance of one Space Station Freedom module) to produce peak currents of 1000 A.

Vaughn, J. A.

Electrical breakdown of Space Station Freedom surfaces

Space Station Freedom (SSF) will be the largest and highest power spacecraft that the U.S. has put into orbit. The solar array will generate 160 volts nominal when in sunlight, and the present baseline design is for the negative end of the solar array to be tied to SSF structure. Due to the balance of leakage currents through the plasma, the structure will be driven approximately 140 volts negative of the ambient conductive ionospheric plasma. Surface materials such as anodized aluminum will have this voltage drop across a thin dielectric which may not have sufficient dielectric strength to prevent dielectric breakdown. This can lead to arcing on the exterior surfaces of Space Station.

Carruth, M. R., Jr.

Atomic oxygen beam source for erosion simulation

A device for the production of low energy (3 to 10 eV) neutral atomic beams for surface modification studies is described that reproduces the flux of atomic oxygen in low Earth orbit. The beam is produced by the acceleration of plasma ions onto a negatively biased plate of high-Z metal; the ions are neutralized and reflected by the surface, retaining some fraction of their incident kinetic energy, forming a beam of atoms. The plasma is generated by a coaxial RF exciter which produces a magnetically-confined (4 kG) plasma column. At the end of the column, ions fall through the sheath to the plate, whose bias relative to the plasma can be varied to adjust the beam energy. The source provides a neutral flux approximately equal to 5 x 10(exp 16)/sq cm at a distance of 9 cm and a fluence approximately equal to 10(exp 20)/sq cm in five hours. The composition and energy of inert gas beams was diagnosed using a mass spectometer/energy analyzer. The energy spectra of the beams demonstrate energies in the range 5 to 15 eV, and qualitatively show expected dependences upon incident and reflecting atom species and potential drop. Samples of carbon film, carbon-based paint, Kapton, mylar, and teflon exposed to atomic O beams show erosion quite similar to that observed in orbit on the space shuttle.

Cuthbertson, J. W.

Characterization of a 5-eV neutral atomic oxygen beam facility

An experimental effort to characterize an existing 5-eV neutral atomic oxygen beam facility being developed at Princeton Plasma Physics Laboratory is described. This characterization effort includes atomic oxygen flux and flux distribution measurements using a catalytic probe, energy determination using a commercially designed quadrupole mass spectrometer (QMS), and the exposure of oxygen-sensitive materials in this beam facility. Also, comparisons were drawn between the reaction efficiencies of materials exposed in plasma ashers, and the reaction efficiencies previously estimated from space flight experiments. The results of this study show that the beam facility is capable of producing a directional beam of neutral atomic oxygen atoms with the needed flux and energy to simulate low Earth orbit (LEO) conditions for real time accelerated testing. The flux distribution in this facility is uniform to +/- 6 percent of the peak flux over a beam diameter of 6 cm.

Vaughn, J. A.

Ring cusp/hollow cathode discharge chamber performance studies

An experimental study was performed to determine the effects of hollow cathode position, anode position, and ring cusp magnetic field configuration and strength on discharge chamber performance. The results are presented in terms of comparative plasma ion energy cost, extracted ion fraction, and beam profile data. Such comparisons are used to demonstrate whether changes in performance are caused by changes in the loss rate of primary electrons to the anode or the loss rate of ions to discharge chamber walls or cathode and anode surfaces. Results show: (1) the rate of primary electron loss to the anode decreases as the anode is moved downstream of the ring cusp toward the screen grid; (2) the loss rate of ions to hollow cathode surfaces are excessive if the cathode is located upstream of a point of peak magnetic flux density at the discharge chamber centerline; and (3) the fraction of the ions produced that are lost to discharge chamber walls and ring magnet surfaces is reduced by positioning of the magnet rings so the plasma density is uniform over the grid surface, and adjusting their strength to a level where it is sufficient to prevent excessive ion losses by Bohm diffusion.

Vaughn, J. A.

Ring cusp/hollow cathode discharge chamber performance studies

An experimental study performed to determine the effects of hollow cathode position, anode position, and ring cusp magnetic field configuration and strength on discharge chamber performance is described. The results are presented in terms of comparative plasma ion energy cost, extracted ion fraction, and beam profile data. Results show that the rate of primary electron loss to the anode decreases as the anode is moved downstream of the ring cusp toward the screen grid and that the loss rate of ions to hollow cathode surfaces are excessive if the cathode is located upstream of a point of peak magnetic flux density at the discharge chamber centerline. Moreover, the fraction of the ions produced that are lost to discharge chamber walls and ring magnet surfaces is reduced by positioning of the magnet rings so the plasma density is uniform over the grid surface, and adjusting their strength to a level where it is sufficient to prevent excessive ion losses by Bohm diffusion.