On the accuracy of Cs beam primary frequency standards

A new and much more exact method for evaluation of the velocity distribution in 10 to the 15th power of the frequency of the clock. It seems feasible to improve the accuracy even further with better measurements. The evaluation of the C-field, however, is still limited to a few parts in 10 to the 14th power because of the uncertainties linked to the method used, and this uncertainty remains one of the major limitations of NRC's primary clocks.

Boulanger, J. S.

Influence of modulation frequency in rubidium cell frequency standards

The error signal which is used to control the frequency of the quartz crystal oscillator of a passive rubidium cell frequency standard is considered. The value of the slope of this signal, for an interrogation frequency close to the atomic transition frequency is calculated and measured for various phase (or frequency) modulation waveforms, and for several values of the modulation frequency. A theoretical analysis is made using a model which applies to a system in which the optical pumping rate, the relaxation rates and the RF field are homogeneous. Results are given for sine-wave phase modulation, square-wave frequency modulation and square-wave phase modulation. The influence of the modulation frequency on the slope of the error signal is specified. It is shown that the modulation frequency can be chosen as large as twice the non-saturated full-width at half-maximum without a drastic loss of the sensitivity to an offset of the interrogation frequency from center line, provided that the power saturation factor and the amplitude of modulation are properly adjusted.

Audoin, C.

Hydrogen maser development at Laval University

The physical construction of two hydrogen masers is described and results of measurements made on one of the masers are given. These include: cavity Q, thermal time constant, line Q, signal power output, magnetic shielding factor. Preliminary results indicate that the frequency stability will be mainly affected by the thermal of the cavity. The magnetic field and the barometric fluctuations should not affect the maser at the stability level above a few parts in 10 to the 15th power, which is the goal for averaging times of several hours.

Vanier, J.

Time domain measurement of frequency stability: A tutorial introduction

The theoretical basis behind the definition of frequency stability in the time domain is outlined. Various types of variances were examined. Their differences and interrelation are pointed out. Systems that are generally used in the measurement of these variances are described.

Vanier, J.

Relaxation and frequency shifts in the ground state of Rb-85

Results are presented on the relaxation and frequency shifts measured for the 0-0 transition of the ground state of Rb-85 at 3.03 GHz in various physical environments. These results include data on spin-exchange, buffer-gas, and wall interactions.

Vanier, J.

Rubidium 87 gas cell studies, phase 2

The design, development, and characteristics of a rubidium 87 maser are discussed. The design of a receiver capable of locking a crystal oscillator to the maser signal is reported. The subjects considered are: (1) maser construction, (2) maser control electronics, (3) the characteristics of the receiver, and (4) results of experimental maser tests.

Vanier, J.

Light shift effects in the Rb-87 maser

Previous work has shown the possibility to overcome the dependence of the Rb-87 maser frequency on light intensity by tuning the cavity at a proper setting. The conditions for this setting, called the light-independent frequency setting (LIFS), are carefully investigated. The results presented prove the existence of the LIFS and provide a new criterion for an automatic cavity tuning of the Rb maser.

Busca, G.

Short-term frequency stability of the Rb-87 maser.

Measurements of the short-term stability of the Rb-87 maser as a function of the maser power output and the receiver cutoff frequency are reported. The experimental data are compared to theoretical results obtained from an approximate theory. In this theory the transfer function of the maser for thermal noise is derived, and the spectral density of the phase fluctuations is calculated. An analytical expression for the 'Allan variance' is also given. A comparison of the stability of the Rb-87 maser with existing frequency standards shows its superiority for averaging times less than 1 sec.

Tetu, M.

Light shift and light broadening in the Rb-87 maser.

A description of measurements of light-shift and light-broadening parameters for an Rb-87 maser operating between the field independent levels is reported. A parallel study of the spectral profile of the D1 pumping line is described. Comparison between the experimental results and theoretical calculations, taking into account the spatial inhomogeneity of the pumping light in the absorption cell, is presented.

Busca, G.

Rubidium-87 gas cell studies, phase 2

A description is given of the development of a compact rubidium-87 maser. Data cover the electronic control system for the maser itself and a superhetrodyne receiver capable of locking a crystal oscillator to the maser signal.

Vanier, J.

Relaxation time measurements by an electronic method.

Description of a simple electronic system that permits the direct measurement of time constants of decaying signals. The system was used in connection with relaxation experiments on hydrogen and rubidium masers and was found to operate well. The use of a computing counter in the systems gives the possibility of making averages on several experiments and obtaining the standard deviation of the results from the mean. The program for the computing counter is given.

Brousseau, R.

Cavity tuning and light-shift in the Rb-87 maser

A new method for tuning the cavity of the Rb-87 maser is proposed. It is based on the existence of a cavity tuning for which the maser frequency is independent on the light intensity. The features of this method are evaluated theoretically and tested experimentally. Preliminary results obtained by using a closed loop feedback electronic system for tuning the cavity are given.

Busca, G.

Rubidium-87 gas cell studies, phase 1

The construction of a quartz bulb-quartz cavity type rubidium maser is described, and the results obtained with two of these masers are presented. The tuning characteristics, medium term stability, and short term stability are reported. It is concluded that the stability of the masers in the short term region is superior to any of the oscillators presently existing. On this basis it is believed that future development of the masers to reduce their size and improve their medium term stability is well justified.

Vanier, J.

Rubidium gas cell studies

The stability of Rb-87 optically pumped masers and Rb gas cells is examined. Descriptions are given of the technical procedures used in construction and the changes made to solve the problems encountered in the electronics of the systems.

Vanier, J.