Engineering Papers⌕ Search

Engineering topics

Van Speybroeck, L. P.

Publications and source records attributed to Van Speybroeck, L. P..

X-ray evidence for particulate contamination on the AXAF VETA-1 mirrors

X-ray testing of the AXAF outer mirror pairs, in the VETA-1 configuration, reveals a point spread function (PSF) with unexpectedly large wings at low energies. Although the angular dependence in the wings of the PSF is close to that expected for diffractive scattering from surface roughness, the energy dependence differs substantially. Analyses of the observed X-ray PSF, images near ring focus, and single-quadrant images at conjugate focus suggest that the excess scattering observed at low X-ray energies results from diffractive scattering by relatively small grains (as small as a few tenths micrometer in radius). We develop a simple model for the contribution of scattering by particulates to the PSF. Merging this model with that for scattering by surface roughness, we fit the combined model to the observed energy-dependent PSF, in order to estimate parameters and associated uncertainties characterizing the grain-size distribution and the surface-roughness power spectral density. In particular, we find that the fractional coverage of the mirrors by particulates is approximately 1 x 10 exp -4 (for grain radii between 0.1 and 10 microns), and that the rms surface-roughness is approximately 0.7 nm (for spatial frequencies between 1/mm and 1000/mm).

O'Dell, S. L.↗

Measurement of the effects of particulate contamination on X-ray reflectivity

Because particles of sizes larger than a few tenths microns adversely affect high resolution X-ray telescopes by scattering and absorbing X-rays, the cleanliness required to maintain the about 1 percent overall calibration precision desired for the Advanced X-ray Astrophysics Facility (AXAF) is being investigated. At the grazing angles used for the AXAF mirrors, each particle shadows a surface area about 100 times its geometric area, necessitating glass occlusion specifications much more stringent than typically stipulated for visible-light particulate contamination. On test flats coated with gold, controlled levels of contamination have been deposited spanning the range from 5 x 10 to the -5th to 0.005 fractional area covered, and the absorption component of extinction has been measured over a range of grazing angles and X-ray energies to verify the predicted effects of particulate contamination.

Slane, P.↗

X-ray testing of the AXAF Technology Mirror Assembly (TMA) mirror

The X-ray performance of the Advanced X-ray Astrophysics Facility TMA in the 0.277-6.4-keV range. The precise figure and smooth surface originally specified (which were expected from the in-process optical and mechanical measurements) are verified. The paper primarily describes the test equipment and methods used and gives examples of the detailed on-axis and off-axis data.

Schwartz, D. A.↗

X-ray emission from normal galaxies

The results of Einstein Observatory studies of X-ray emission from normal galaxies, including the LMC and SMC, M31, M33, M101, NGC 247, M81 and M100, and N253 are surveyed. The X-ray luminosity of normal galaxies is proportional to their optical luminosity, revealing no strong dependence on galaxy type. The number of individual sources detected are comparable to the number of sources expected on mass considerations. There are substantial numbers of X-ray sources in the Magellanic Clouds with luminosities in the range 10 to the 35th-36th ergs/s, lower than most X-ray binaries but higher than known uncollapsed stellar systems. About seven X-ray sources with luminosities of at least 10 to the 39th ergs/s in the 0.5-3.0 keV band have been found in the arms of nearby spiral galaxies.

Long, K. S.↗

Einstein Observatory /HEAO-B/ mirror design and performance

The mirrors for the Einstein Observatory represent a substantial advance in the state of the art X-ray optics, and have been tested more thoroughly than previous telescopes. The image is characterized by a narrow, wavelength independent core, and broad energy dependent wings. The width of the core is about that expected from mechanical and visible light measurements taken during fabrication and assembly. The wings of the response function are caused by microscopic surface scattering, but only a qualitative understanding of this process exists. Improvement in surface texture to reduce the wide angle scatter is the most urgent task in the development of large X-ray optics. The mirrors have survived the experiment integration period and launch, and are performing in orbit as they performed upon the ground.

Van Speybroeck, L. P.↗

Diffraction grating transmission efficiencies for XUV and soft X rays

The manufacture and properties of a grating intended for extrasolar X-ray studies are described. The manufacturing process uses a split laser beam exposing an interference pattern on the photoresist-coated glass plated with a nickel parting layer. The grating, supporting structure, and mounting frame are electrodeposited on the nickel parting layer, and the final product is lifted from the glass substrate by selective etching of the nickel. A model was derived which relates the number of counts received in a given order m as a function of photon wavenumber. A 4-deg beam line was used to measure the efficiencies of gold transmission gratings for diffraction of X-rays in the range of 45 to 275 eV. The experimental results are in good agreement with model calculations.

Schnopper, H. W.↗

Design, fabrication and expected performance of the HEAO-B X ray telescope

The X-ray telescope of the second High Energy Astronomy Observatory (HEAO-B) is described. The design consists of four concentric paraboloid/hyperboloid pairs. Focal length is 3.44 meters, paraboloid diameters vary from 580-336 mm, grazing angles vary from 70 to 40 arcmin for paraxial rays, segment lengths are 511 mm. The reflecting surfaces are nickel-coated fused quartz and the resolution is limited by assembly errors (for small field angles) and design aberrations (for large field angles). The local slope, roundness, and surface roughness are identified as the primary optical tolerances connected with the individual elements.

Van Speybroeck, L. P.↗

High resolution imaging X-ray detector for astronomical measurements

The article describes the X-ray detector which will provide second-of-arc images for the HEAO-B X-ray observatory. The instrument uses microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. Position determination is accomplished by electronic interpolation between the coarse grid wires. The detector provides the arrival time and position of each event which occurs within its field of view. Measurements of the spatial resolution (15 microns), temporal resolution (7.8 microsec), image distortion (less than 10 microns), uniformity of efficiency (less than plus or minus 10%), dark counting rate (0.2 cts/sq cm/s), and quantum efficiency (10% at 1.54 keV) of this detector are described. A summary of the procedure which was found useful during the initial turn-on of microchannel plates is given.

Henry, J. P.↗

The X-ray corona and the photospheric magnetic field.

Soft X-ray photographs of the solar corona have been obtained on four flights of a rocket-borne grazing incidence telescope having a resolution of a few arc sec. The configuration of the X-ray emitting structures in the corona has been compared to the magnetic field distribution measured by photospheric longitudinal magnetograms. The X-ray structures trace the three-dimensional configuration of the magnetic field through the lower corona. Active regions in the corona take the form of tubular structures connecting regions of opposite magnetic polarity within the same or adjacent chromospheric active regions. Higher, larger structures link widely separated active regions into complexes of activity covering substantial fractions of the disk. The complexes are separated by areas of low average field in the photosphere. Interconnections across the solar equator appear to originate over areas of preceding polarity.

Krieger, A. S.↗