Engineering PapersSearch

Engineering topics

Van Sciver, S. W.

Publications and source records attributed to Van Sciver, S. W..

Cooling options for Astromag

A comparison of the various cooling options for the Astromag particle physics experiment is presented. The baseline design for the cryogenic system involves using a natural circulation fountain-effect driven flow loop (Hofmann type). The present paper considers two alternative options for cooling. The first design involves a thermal strap made of a high-conductivity metal, e.g., high-purity aluminum or copper, which connects the coil to the helium reservoir. Venting helium vapor can also be used to minimize the temperature of the magnet and recover from a quench. The second design is based on an He II heat pipe concept where steady state heat transport is by counterflow. Cavitation is prevented by use of a porous plug. Forced flow He II is also available but only during extraordinary operating conditions.

Maytal, B. Z.

Characterizing He II flow through porous materials using counterflow data

An empirical extension of the two-fluid model is used to characterize He II flow through porous materials. It is shown that four empirical parameters are necessary to describe the pressure and temperature differences induced by He II flow through a porous sample. The three parameters required to determine pressure differences are measured in counterflow and found to compare favorably with those for isothermal flow. The fourth parameter, the Gorter-Mellink constant, differs substantially from smooth tube values. It is concluded that parameter values determined from counterflow can be used to predict pressure and temperature differences in a variety of flows to an accuracy of about +/- 20 percent.

Maddocks, J. R.

Thermal behavior of the SHOOT gallery arm

The planned Superfluid Helium On-Orbit Transfer (SHOOT) experiment will show the feasibility of resupplying orbiting facilities with liquid helium. The SHOOT experiment, designed for transfer rates of 300 to 800 liters/hr, will use a thermomechanical pump and four screen covered flow channels for fluid acquisition. Cavitation and thermal behavior was examined in ground based tests of the pump and of a full sized channel. A model for estimating the temperature profile at the pump inlet is presented. Large temperature increases in this region can significantly degrade the performance of the fountain pump.

Nissen, J. A.

Iso-chemical potential trajectories in the P-T plane for He II

Trajectories of constant chemical potential in the P-T plane serve as an integral formulation of London's equation. The trajectories are useful for analysis and synthesis of fountain effect pump performance. A family of trajectories is generated from available numerical codes.

Maytal, B.

Pressure drop in the SHOOT superfluid helium acquisition system

Central to the upcoming Superfield Helium On-Orbit Transfer (SHOOT) demonstration is the fluid acquisition system. The main component of the system is a rectangular cross-section gallery area with one side fabricated from a fine mesh screen. He II enters through the screen and is delivered to a fountain effect pump. A model is proposed to predict the pressure drop as fluid flows through the screen and an expression is derived for the required gallery arm length as a function of flow rate demand. The model is compared with measurement of pressure drop in a full scale SHOOT gallery arm operated with flow rates of up to 850 cu dm/hr. The tests were conducted in the University of Wisconsin horizontal liquid helium flow facility to minimize gravitational effects.

Nissen, J. A.

Pressure drop of He II flow through a porous media

The paper reports on measurements of He II pressure drop across two porous SiO2 ceramic filter materials. These materials vary only in porosity, having values of 0.94 and 0.96. The average fiber diameter in both cases is approximately 5 microns. The experiment consists of a glass tube containing a piece of this sponge in one end. The tube is rapidly displaced downward in a bath of helium and the liquid levels are allowed to equilibrate over time producing variable velocities up to 10 cm/sec. The results are compared with those previously obtained using fine mesh screens. Good qualitative agreement is observed for turbulent flow; however, the behavior in the laminar flow regime is not fully understood.

Maddocks, J. R.

Forced flow He II in relation to stability of internally cooled superconductors

Current understanding of forced flow He II as it is used to cool large superconducting devices is presented. Experimental measurements of pressure loss and heat transfer to He II at relatively high flow rates are compared with classical hydrodynamic relations and theoretical models based on two fluid hydrodynamics. The results of this analysis suggest that reliable design of large scale systems is achievable. Implications to forced flow He II cooling of superconducting magnets are discussed in the context of model stability experiments on internally cooled composite superconductors.

Van Sciver, S. W.

Pressure drop and He II flow through fine mesh screens

Fluid acquisition systems for He II transfer devices will utilize gallery arms to ensure that the fluid encounters the pump inlet. In near term experiments such as Superfluid Helium on Orbit Transfer (SHOOT), the preferred configuration consists of several rectangular channels which have one side made from a Dutch weave stainless steel screen having 325 x 2300 wires per inch. The effective pore diameter for this screen is about 5 microns. The present paper reports on measurements of pressure drop across a screen when it is subjected to a flow of liquid helium. The experiment measures the time rate of change of the level in two different helium reservoirs connected by a screen-blocked channel. Results with normal helium are compared with predictions based on the Armour-Cannon (1968) equations. The He II data show considerable deviation from the classical result. A discussion of the He II pressure drop results in terms of two fluid hydrodynamics is included.

Maddocks, J. R.

Turbulent flow preasure drop in various He II transfer system components

Pressure drop experiments in highly turbulent He II flow were performed in flow loops driven by either a centrifugal pump or a single-stroke bellows pump. Pressure drops in straight tubing, coiled tubing, bellows sections, valves and Venturi flow meters were measured over a range of flow rates and temperatures. Our pressure drop data are in general agreement with classical fluid correlations when the He II normal component viscosity is used in calculating the Reynolds number. Cavitation and, in some cases, metastable superheating were observed in pressure drop measurements with Venturis in both centrifugal and bellows pump flow circuits.

Walstrom, P. L.

Characterization of a centrifugal pump in He II

As part of an effort to determine the feasibility of helium transfer in space, a centrifugal pump was tested in He II at a variety of flow rates, pump speeds, and fluid temperatures. The pump, which has a straight bladed impeller 6.86 cm in diameter, generated a maximum pressure rise of 15 kPa and a maximum flow rate of 22 g/s for the conditions of the test. Pump performance seems to be independent of fluid temperature and is in good agreement with the values predicted by the manufacturer. Over the range of flow coefficients, the measured maximum efficiency is around 50 percent. Cavitation is observed in the pump and is thought to be highly dependent on the local heating of the helium in the pump. Preliminary measurements of the noise spectra of the pump suggest a possible mechanism to predict the onset of cavitation.

Weisend, J. G., II

Effects of oxidation and roughness on Cu contact resistance from 4 to 290 K

Knowledge of the factors influencing contact resistance is important for optimizing system design in cryogenic applications. In space cryogenics, indirect cooling of infrared components is the primary concern. The presence of bolted joints results in contact resistances which can dominate all other contributions to the overall heat transfer rate. Here, thermal and electrical contact resistances measured between 4 K and 290 K for a series of bolted OFHC Cu contacts are reported. Surface roughness is found to have little effect on the overall contact resistance within the experimental limits, while oxidation can increase the contact resistance by as much as a factor of 100. Thermal and electrical contact resistances measured on the same contact show that the contact resistance temperature dependence does not follow the bulk dependence. For example, the residual resistance ratio (RRR) of the OFHC Cu is 110, but for contacts made from this material, the RRR is about two.

Nilles, M. J.