Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.
This document addresses parts 2 and 3 of the original milestone request. In the following writeup, the development of OpSpecTR at LLNL by LLNL and NNSS personnel will be detailed first, followed by a write-up of the development of Vme-resolved simulaVons of the opacity-on-NIF experiment. Capsule backlight simulaVons, hohlraum simulaVons, and sample simulaVons from CASSIO are combined to produce the line of sight from the capsule to an effecVve OpSpec posiVon. Spectra are generated by post-processing these simulaVons from either Spect3D, a commercial software by Prism ComputaVonal Sciences, or FESTR (Finite Element Spectroscopic Transport of RadiaVon), a LANL code. While the simulaVons do not at this stage proceed late enough to include the worst of the backgrounds generated from the hohlraum experimentally and each post-processing simulaVon includes only one ray for each spectrometer channel, these efforts represent proof of concept for a new capability to complete Vme-resolved and Vmegated simulaVons for the complete line of sight of the complex opacity-on-NIF geometry. Future work will be discussed at the end of the report for both efforts.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Los Alamos National Laboratory is a nuclear weapons laboratory supporting our nation's defense. In support of the mission is a high energy-density physics program in which we design and execute experiments to study radiation-hydrodynamics phenomena and improve the predictive capability of our large-scale multi-physics software codes on our supercomputers. The Radflow Project is maturing a unique spectroscopic measurement that yields a spatially dependent supersonic radiation wavefront profile. The spectroscopic measurement is much more constraining than the typically used radiography, which measures the density changes due to the shock as the radiation wave goes subsonic. Recently, the spectroscopic measurement has been applied to advanced targets with a detailed heterogeneity representing a single realization of a stochastic medium. The Radflow Project also conducts opacity experiments to explain the current conundrum of the experimental iron opacity differing from theory, which is important in modeling the sun. More than that, though, we need to be able to answer these science questions and be able to validate our theory and codes.
The XFOL campaign is continuing to study radiation flow in stochastic media. Purpose: Simultaneously measure the ionization state of the background and inclusions of a binary stochastic media using the COAX/OUTI diagnostic. Motivation: Radflow is stochastic media is of wide, growing interest and COAX is a new powerful diagnostic that can characterize the radflow physics and validate codes, models, and their underlying assumptions.
Here, the goal of the Xflows experimental campaign is to study the radiation flow on the National Ignition Facility (NIF) reproducing the sensitivity of the temperature (±8 eV, ±23 μm) and density (±11 mg/cc) measurements of the COAX platform. This new platform will enable future astrophysical experiments involving supernova shock breakout, such as Radishock on OMEGA-60, and stochastic media (such as XFOL on OMEGA). Greater energy and larger physical scale on NIF will enable a greater travel distance of radiation flow, higher density, and more manufacturable foams and enable exploration of a greater range of radiation behavior than achievable in the prior OMEGA experiments. This publication will describe the baseline configuration for the Xflows experimental campaign and the roadmap to achieve its primary objectives.
Spectral diagnostics provide a powerful probe of high energy-density physics experiments. By shining an x-ray source on a target, absorption features can be used to determine accurate temperature profiles of that target material. Many studies produce a single temperature/density measurement by fitting these observed spectra. This paper demonstrates how, by leveraging detailed simulations, we can not only measure the average temperature and density, but the full density and temperature profiles. To do so, we must conduct a careful analysis of the uncertainties in the diagnostic measurement. Here we discuss the characteristics and associated uncertainties of the spectral diagnostic used in the COAX, Radishock and OuTi experiments, ultimately demonstrating how these detailed studies increase the potential of this powerful probe.
The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure opacities at varying densities and temperatures relevant to the solar interior and thermal cooling rates in white dwarf stars. The typical temperatures reached at NIF range between 150 and 210 eV, which allow these measurements to be performed experimentally. The captured opacities are crucial to validating radiation-hydrodynamic models that are used in astrophysics. The NIF opacity platform has a unique new capability that allows in situ measurement of the sample expansion. The sample expansion data are used to better understand the plasma conditions in our experiments by inferring the sample density throughout the duration of the laser drive. Here, we present the details of the density measurement technique, data analysis, and recent results for Fe and MgO.
When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.
Explore the source record for details and available documents.
A growing number of astrophysical transients are pushing astronomers to develop increasingly complex computational tools to model both radiation hydrodynamics and electron transport. Here we review the physics needs and simulation uncertainties associated with modeling these transients. Although this review will focus on theory and simulation aspects of this problem, we also review some experiments designed to study this physics.
Predicting and matching radiation wave propagation with computational models has proven difficult. Information provided by experiments studying radiation flow has been limited when only radiation breakout is measured. We have developed the COAX (co-axial) diagnostic platform to provide spatial temperature profiles of a radiation wave through low density foams as a more detailed constraint for simulations. COAX uses a standard, laser-driven OMEGA-60 halfraum to drive radiation down a titanium-laden silicon oxide foam. Point-projection X-ray absorption spectroscopy perpendicular to the radiation flow measures the spatial profile of titanium ionization. The spectroscopic measurement utilizes a broadband capsule backlighter. Imaging and streak spectroscopy are used to characterize the size and spectrum of this source. Radiography provides an additional constraint by capturing the developing shock as the radiation flow becomes subsonic. The DANTE diagnostic is used to measure the halfraum temperature. Here, we provide a spectroscopic analysis of COAX data to determine temperature, and we describe experimental sources of uncertainty. The temperature is obtained by comparison to multi-temperature synthetic spectra post-processed from radiation-hydrodynamics simulations. Quantitative comparison between data and synthetic spectra generated from temperature profiles at relevant simulation times enable determination of a peak temperature of 114 ± 8 eV at 265 ± 22.4 μm from the halfraum. This represents an improvement over the temperature uncertainties of previous radiation flow experiments. Further refinements to the spectroscopic analysis could achieve ±4 eV. The combination between space-resolved spectroscopy and radiography enables us to determine the distance from the halfraum of both the radiation front and the shock front at the time of measurement. For the example shown in this paper the radiation front position is 600–630 μm at 3.43 ± 0.16 ns and the shock front position is 633 μm at 3.3 ± 0.24 ns.
Conclusions reached are: Increasing backlighter thickness from 19 um to 21 um raises the peak flux by 15%; Adding a density gradient may not significantly change signal output from the backlighter; and, 2D simulations are needed to model closer-to-design problems
Explore the source record for details and available documents.
This presentation covers the following topics: Opacity in HED Astrophysics; HED Opacity Experiments; Bad Foils in Opacity Experiments; Bad Foils in Simulated Opacity Experiments