Engineering Papers⌕ Search

Engineering topics

Unruh, Troy

Publications and source records attributed to Unruh, Troy.

At least 37 records · Page 2

Conceptual Design Report for the I2 Instrumentation Experiment in ATRC

The US Department of Energy In-Pile Instrumentation (I2) program is tasked with developing advanced sensors for in-pile service as well as supporting the engineering required to implement existing nuclear sensor technologies in US high-power test reactors. The ATRC instrumentation test has been conceived to address both of these missions, specifically with respect to neutron flux measurements. Space has been allocated in the test for Self-Powered Neutron Detectors (SPNDs), fission chambers, and Micro-Pocket Fission Detectors (MPFDs). The real-time flux readings obtained from these instruments will be compared with time integrated data obtained from passive neutron dosimetry (i.e., “flux” wires). This work will be complementary to data obtained from the TREAT MIMIC-N experiment. This experiment is expected to support instrumentation efforts related to the proposed Medium-I loop and to instrumenting loop experiments conducted in the ATR center flux trap. While the MIMIC-N experiment was conducted in a dry environment, the ATRC I-19 experiment will be conducted in an aqueous environment, similar to the center flux trap loop experiments but will take place at ambient temperature and pressure, and at a much lower neutron flux. One of the challenges of the ATRC I-19 experiment will be low amplitude signals produced by the sensors in the low neutron fluxes of ATRC. However, related work conducted several years ago in ATRC was able to reliably detect signals using a similar instrument set.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro Reactor Instrumentation and Control FY2019 Report

Micro-reactors (i.e., very small transportable or mobile nuclear reactors with a capacity less than 20 MWt) are being developed to supply heat and power for various applications in remote areas, military installations, emergency operations, humanitarian missions, and disaster relief zones. A wide variety of reactor types are under consideration, including sodium-cooled fast reactors, molten salt reactors, light water reactors, very-high-temperature gas reactors, and heat pipe reactors. These miniaturized transportable reactor designs remain largely untested and unproven. System and component testing are needed to demonstrate design safety and system robustness, reliability and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Recovery of Silicon Carbide monitor irradiation temperature via continuous resistance measurement during annealing (Pt. II)

Silicon carbide (SiC) monitors provide a means of measuring peak irradiation temperature of experiment capsules in nuclear irradiation experiments. Neutron irradiation of a SiC monitor causes permanent lattice changes that are removed by annealing via heating to a temperature that exceeds the peak irradiation temperature. The annealing process results in changes to SiC physical characteristics that can be observed during the annealing process. This paper presents results of a method aimed at using electrical resistance, measured during a two-pass heating – cooling cycle as a means of recovering the irradiation temperature of a SiC monitor. Results indicate that the relationship between resistance and temperature of a SiC monitor shows a significant change in slope when the peak irradiation temperature is reached. This demonstrates the potential for this method to replace the current manual, and lengthy, process of post irradiation examination used to extract the peak irradiation temperature from irradiated SiC monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse Mode Calibration of the Micro Pocket Fission Detector

The Micro-Pocket Fission Detector (MPFD) is a neutron sensor currently under development in the High Temperature Test Laboratory (HTTL) for use as a supporting instrument during material testing experiments performed at TREAT. The detector has the capability to observe the real-time neutron population while surviving the harsh radiation, and temperature conditions, which sets it apart from most neutron sensitive devices. The next step in the instrument development process is to define a method of calibrating pulse-mode operations. This procedure will allow the detector to be calibrated to allow for absolute measurements of localized neutron population in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Micro-Pocket Fission Detector for High Temperature Reactors - FY17 FInal Project Report

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core fission chambers and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for this three year project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY17 Report for Instrumentation Development for the Transient Testing Program

This report details the technical activities and accomplishment carried out under the in-pile instrumentation work package supporting the transient testing program. These activities were performed in direct support of cross-cutting transient testing experiment objectives. The purpose of this report is to provide a complete summary of all work, which is of particular interest to nuclear irradiation test experimenters and in-pile instrumentation engineers with emphasis on transient testing applications. Development activities are focused on devices to perform online measurement of neutron flux, temperature, and mechanical behaviors in nuclear fuels experiments. A brief summary of activities and accomplishments is first provided for each major activity. Detailed reports are presented in appendices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced micro-pocket fission detector for high temperature reactor evaluations - 259

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat a l'energie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 deg. C. The MPFD technology utilizes small, multi-purpose, robust, in-core fission chambers and can be configured with a thermocouple. The small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. In addition, the accomplishments of this project have attracted independent funding from other Department of Energy Office of Nuclear Energy (DOE-NE) programs for MTR irradiations of the MPFD technology. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NEET Enhanced Micro-Pocket Fission Detector for High Temperature Reactors - FY16 Status Report

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core fission chambers and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for year two of this three year project. Highlights from research accomplishments include: • Continuation of a joint collaboration between INL, KSU, and CEA. Note that CEA is participating at their own expense because of interest in this unique new sensor. • An updated parallel wire HT MPFD design was developed. • Program support for HT MPFD deployments was given to Accident Tolerant Fuels (ATF) and Advanced Gas-cooled Reactor (AGR) irradiation test programs. • Quality approved materials for HT MPFD construction were procured by irradiation test programs for upcoming deployments. • KSU improved and performed electrical contact and fissile material plating. • KSU delivered fissile HT MPFD parts to INL for final construction of HT MPFD prototype. • A prototype HT MPFD was constructed and analyzed at INL. • The HT MPFD has been modeled in MCNP to optimize the amount of fissile material deposition. • The HT MPFD has been modeled in MCNP to optimize the sensor location in the irradiation test. • The fissile material deposition is undergoing independent verifications. • Detector amplifier electronics have been revised and tested by KSU. • Several project meetings were held at INL and KSU to discuss the roles and responsibilities between INL, KSU, and CEA for development and deployment of the HT MPFDs. As documented in this report, FY16 funding has allowed the project to meet year two planned accomplishments to develop a HT MPFD. In addition, the accomplishments of this project have attracted independent funding from other Department of Energy Office of Nuclear Energy (DOE-NE) programs for MTR irradiations of the MPFD technology. These are significant opportunities for this NEET Enhanced Micro-Pocket Fission Detector for High Temperature Reactors project because the irradiation expense of these experiments could not be included in the original project scope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation Development for Transient Testing in TREAT

Development of nuclear fuels requires experimentation and modeling for behavior during transient power and cooling conditions. The Transient Reactor Test facility (TREAT) will provide unique capability in the U.S. to perform controlled experimentation of such conditions in a nuclear environment. To support experiment objectives and provide validation data for modeling and simulation tools, experiment instrumentation plays a critical role in monitoring test specimen behavior (temperature, dimensional changes, relocation, microstructural evolution, etc.) and specimen boundary conditions (thermal, mechanical, nuclear) at various length and time scales with the ultimate goal of reducing uncertainties in experiment conditions. This summary presents an overview of current instrument development objectives and progress for TREAT experiments with emphasis on near-term activities to support Reactivity Initiated Accident (RIA) experiments in LWR systems. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NEET Enhanced Micro Pocket Fission Detector for High Temperature Reactors - FY15 Status Report

A new project, that is a collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core parallel plate fission chamber and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for year one of this three year project. Highlights from research accomplishments include: A joint collaboration was initiated between INL, KSU, and CEA. Note that CEA is participating at their own expense because of interest in this unique new sensor. An updated HT MPFD design was developed. New high temperature-compatible materials for HT MPFD construction were procured. Construction methods to support the new design were evaluated at INL. Laboratory evaluations of HT MPFD were initiated. Electrical contact and fissile material plating has been performed at KSU. Updated detector electronics are undergoing evaluations at KSU. A project meeting was held at KSU to discuss the roles and responsibilities between INL and KSU for development of the HT MPFDs. Provide input to various irradiation programs for installation of the MPFD technology in irradiation tests. As documented in this report, FY15 funding has allowed the project to meet year one planned accomplishments to develop a HT MPFD that offers US MTR users enhanced capabilities for real-time measurement of flux and temperature with a single detector. In addition, the accomplishments of this project have attracted funding from other Department of Energy Office of Nuclear Energy (DOE-NE) programs for additional applications. The work in those programs will build on current activities completed in this NEETASI HT MPFD project, but the MPFD will be specifically tailored to meet their program needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IN-CORE FLUX SENSOR EVALUATIONS AT THE ATR CRITICAL FACILITY.

As part of an Idaho State University (ISU)–led Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) collaborative project that includes Idaho National Laboratory (INL) and the French Alternative Energies and Atomic Energy Commission (CEA), flux detector evaluations were completed to compare their accuracy, response time, and longduration performance. Special fixturing, developed by INL, allows real-time flux detectors to be inserted into various Advanced Test Reactor Critical Facility (ATRC) core positions to perform lobe power measurements, axial flux profile measurements, and detector crosscalibrations. Detectors initially evaluated in this program included miniature fission chambers, specialized self-powered neutron detectors (SPNDs), and specially developed commercial SPNDs. Results from this program provide important insights related to flux detector accuracy and resolution for subsequent ATR and CEA experiments and yield new flux data required for benchmarking models in the ATR Life Extension Program (LEP) Modeling Update Project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-core flux sensor evaluations at the ATR critical facility

Flux detector evaluations were completed as part of a joint Idaho State University (ISU) / Idaho National Laboratory (INL) / French Atomic Energy commission (CEA) ATR National Scientific User Facility (ATR NSUF) project to compare the accuracy, response time, and long duration performance of several flux detectors. Special fixturing developed by INL allows real-time flux detectors to be inserted into various ATRC core positions and perform lobe power measurements, axial flux profile measurements, and detector cross-calibrations. Detectors initially evaluated in this program include the French Atomic Energy Commission (CEA)-developed miniature fission chambers; specialized self-powered neutron detectors (SPNDs) developed by the Argentinean National Energy Commission (CNEA); specially developed commercial SPNDs from Argonne National Laboratory. As shown in this article, data obtained from this program provides important insights related to flux detector accuracy and resolution for subsequent ATR and CEA experiments and flux data required for bench-marking models in the ATR V&V Upgrade Initiative.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Back-to-Back Fission Chamber Testing in ATRC

Development and testing of in-pile, real-time neutron sensors for use in Materials Test Reactor experiments is an ongoing project at Idaho National Laboratory. The Advanced Test Reactor National Scientific User Facility has sponsored a series of projects to evaluate neutron detector options in the Advanced Test Reactor Critical Facility (ATRC). Special hardware was designed and fabricated to enable testing of the detectors in the ATRC. Initial testing of Self-Powered Neutron Detectors and miniature fission chambers produced promising results. Follow-on testing required more experiment hardware to be developed. The follow-on testing used a Back-to-Back fission chamber with the intent to provide calibration data, and a means of measuring spectral indices. As indicated within this document, this is the first time in decades that BTB fission chambers have been used in INL facilities. Results from these fission chamber measurements provide a baseline reference for future measurements with Back-to-Back fission chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEET Micro-Pocket Fission Detector – FY 2013 Status Report

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the Commissariat à l'Énergie Atomique et aux Energies Alternatives (CEA), is funded by the Nuclear Energy Enabling Technologies (NEET) program to develop and test Micro-Pocket Fission Detectors (MPFDs), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux, and temperature within a single package.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro-Pocket Fission Detectors (MPFD) For Fuel Assembly Analysis

Neutron sensors capable of real-time measurement of thermal flux, fast flux, and temperature in a single miniaturized probe are needed in irradiation tests required to demonstrate the performance of candidate new fuels, and cladding materials. In-core ceramic-based miniature neutron detectors or “Micro-Pocket Fission Detectors” (MPFDs) have been studied at Kansas State University (KSU). The first MPFD prototypes were tested in various neutron fields at the KSU TRIGA research reactor with successful results. Currently, a United States Department of Energy-sponsored joint KSU/Idaho National Laboratory (INL) effort is underway to develop a high-temperature, high-pressure version of the MPFD using radiation-resistant, high temperature materials, which would be capable of withstanding irradiation test conditions in high performance material and test reactors (MTRs). Ultimately, this more compact, more accurate, and longer lifetime flux sensor for critical mock-ups, existing and advanced reactor designs, high performance MTRs, and transient test reactors has the potential to lead to higher accuracy and resolution data from irradiation testing, more detailed core flux measurements and enhanced fuel assembly processing. Prior evaluations by KSU indicate that these sensors could also be used to monitor burn-up of nuclear fuel. If integrated into nuclear fuel assemblies, MPFDs offer several advantages to current spent fuel management systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NEET Micro-Pocket Fission Detector - FY 2012 Status Report

A research program has been initiated by the NEET program for developing and testing compact miniature fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package. When implemented, these sensors will significantly advance flux detection capabilities for irradiation tests in US Materials Test Reactors (MTRs). Ultimately, evaluations may lead to a more compact, more accurate, and longer lifetime flux sensor for critical mock-ups, high performance reactors and commercial nuclear power plants. Deployment of Micro-Pocket Fission Detectors (MPFDs) in US DOE-NE program irradiation tests will address several challenges: Current fission chamber technologies do not offer the ability to measure fast flux, thermal flux and temperature within a single compact probe, MPFDs offer this option. MPFD construction is very different then current fission chamber construction; the use of high temperature materials allow MPFDs to be specifically tailored to survive harsh conditions in typical high performance MTR irradiation tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhanced In-Pile Instrumentation at the Advanced Test Reactor

Many of the sensors deployed at materials and test reactors cannot withstand the high flux/high temperature test conditions often requested by users at U.S. test reactors, such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory. To address this issue, an instrumentation development effort was initiated as part of the ATR National Scientific User Facility in 2007 to support the development and deployment of enhanced in-pile sensors. This paper provides an update on this effort. Specifically, this paper identifies the types of sensors currently available to support in-pile irradiations and those sensors currently available to ATR users. Accomplishments from new sensor technology deployment efforts are highlighted by describing new temperature and thermal conductivity sensors now available to ATR users. Efforts to deploy enhanced in-pile sensors for detecting elongation and real-time flux detectors are also reported, and recently-initiated research to evaluate the viability of advanced technologies to provide enhanced accuracy for measuring key parameters during irradiation testing are noted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗