Engineering Papers⌕ Search

Engineering topics

Unkelbach, Jan

Publications and source records attributed to Unkelbach, Jan.

Joint Optimization of Photon–Carbon Ion Treatments for Glioblastoma

Carbon ions are radiobiologically more effective than photons and are beneficial for treating radioresistant gross tumor volumes (GTV). However, owing to a reduced fractionation effect, they may be disadvantageous for treating infiltrative tumors, in which healthy tissue inside the clinical target volume (CTV) must be protected through fractionation. This work addresses the question: What is the ideal combined photon–carbon ion fluence distribution for treating infiltrative tumors given a specific fraction allocation between photons and carbon ions?.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal Allocation of Proton Therapy Slots in Combined Proton-Photon Radiation Therapy

Proton therapy is a limited resource that is not available to all patients who may benefit from it. We investigated combined proton-photon treatments, in which some fractions are delivered with protons and the remaining fractions with photons, as an approach to maximize the benefit of limited proton therapy resources at a population level.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reoptimization of Intensity Modulated Proton Therapy Plans Based on Linear Energy Transfer

Purpose: We describe a treatment plan optimization method for intensity modulated proton therapy (IMPT) that avoids high values of linear energy transfer (LET) in critical structures located within or near the target volume while limiting degradation of the best possible physical dose distribution. Methods and Materials: To allow fast optimization based on dose and LET, a GPU-based Monte Carlo code was extended to provide dose-averaged LET in addition to dose for all pencil beams. After optimizing an initial IMPT plan based on physical dose, a prioritized optimization scheme is used to modify the LET distribution while constraining the physical dose objectives to values close to the initial plan. The LET optimization step is performed based on objective functions evaluated for the product of LET and physical dose (LET×D). To first approximation, LET×D represents a measure of the additional biological dose that is caused by high LET. Results: The method is effective for treatments where serial critical structures with maximum dose constraints are located within or near the target. We report on 5 patients with intracranial tumors (high-grade meningiomas, base-of-skull chordomas, ependymomas) in whom the target volume overlaps with the brainstem and optic structures. In all cases, high LET×D in critical structures could be avoided while minimally compromising physical dose planning objectives. Conclusion: LET-based reoptimization of IMPT plans represents a pragmatic approach to bridge the gap between purely physical dose-based and relative biological effectiveness (RBE)-based planning. The method makes IMPT treatments safer by mitigating a potentially increased risk of side effects resulting from elevated RBE of proton beams near the end of range.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatiotemporal Fractionation Schemes for Irradiating Large Cerebral Arteriovenous Malformations

Purpose: To optimally exploit fractionation effects in the context of radiosurgery treatments of large cerebral arteriovenous malformations (AVMs). In current practice, fractionated treatments divide the dose evenly into several fractions, which generally leads to low obliteration rates. In this work, we investigate the potential benefit of delivering distinct dose distributions in different fractions. Methods and Materials: Five patients with large cerebral AVMs were reviewed and replanned for intensity modulated arc therapy delivered with conventional photon beams. Treatment plans allowing for different dose distributions in all fractions were obtained by performing treatment plan optimization based on the cumulative biologically effective dose delivered at the end of treatment. Results: We show that distinct treatment plans can be designed for different fractions, such that high single-fraction doses are delivered to complementary parts of the AVM. All plans create a similar dose bath in the surrounding normal brain and thereby exploit the fractionation effect. This partial hypofractionation in the AVM along with fractionation in normal brain achieves a net improvement of the therapeutic ratio. We show that a biological dose reduction of approximately 10% in the healthy brain can be achieved compared with reference treatment schedules that deliver the same dose distribution in all fractions. Conclusions: Boosting complementary parts of the target volume in different fractions may provide a therapeutic advantage in fractionated radiosurgery treatments of large cerebral AVMs. The strategy allows for a mean dose reduction in normal brain that may be valuable for a patient population with an otherwise normal life expectancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated iterative beam angle selection in IMRT

Purpose: Iterative methods for beam angle selection (BAS) for intensity-modulated radiation therapy (IMRT) planning sequentially construct a beneficial ensemble of beam directions. In a naïve implementation, the nth beam is selected by adding beam orientations one-by-one from a discrete set of candidates to an existing ensemble of (n − 1) beams. The best beam orientation is identified in a time consuming process by solving the fluence map optimization (FMO) problem for every candidate beam and selecting the beam that yields the largest improvement to the objective function value. This paper evaluates two alternative methods to accelerate iterative BAS based on surrogates for the FMO objective function value. Methods: We suggest to select candidate beams not based on the FMO objective function value after convergence but (1) based on the objective function value after five FMO iterations of a gradient based algorithm and (2) based on a projected gradient of the FMO problem in the first iteration. The performance of the objective function surrogates is evaluated based on the resulting objective function values and dose statistics in a treatment planning study comprising three intracranial, three pancreas, and three prostate cases. Furthermore, iterative BAS is evaluated for an application in which a small number of noncoplanar beams complement a set of coplanar beam orientations. This scenario is of practical interest as noncoplanar setups may require additional attention of the treatment personnel for every couch rotation. Results: Iterative BAS relying on objective function surrogates yields similar results compared to naïve BAS with regard to the objective function values and dose statistics. At the same time, early stopping of the FMO and using the projected gradient during the first iteration enable reductions in computation time by approximately one to two orders of magnitude. With regard to the clinical delivery of noncoplanar IMRT treatments, we could show that optimized beam ensembles using only a few noncoplanar beam orientations often approach the plan quality of fully noncoplanar ensembles. Conclusions: We conclude that iterative BAS in combination with objective function surrogates can be a viable option to implement automated BAS at clinically acceptable computation times.

61 RADIATION PROTECTION AND DOSIMETRY↗

Degradation of proton depth dose distributions attributable to microstructures in lung-equivalent material

Purpose: The purpose of the work reported here was to investigate the influence of sub-millimeter size heterogeneities on the degradation of the distal edges of proton beams and to validate Monte Carlo (MC) methods’ ability to correctly predict such degradation. Methods: A custom-designed high-resolution plastic phantom approximating highly heterogeneous, lung-like structures was employed in measurements and in Monte Carlo simulations to evaluate the degradation of proton Bragg curves penetrating heterogeneous media. Results: Significant differences in distal falloff widths and in peak dose values were observed in the measured and the Monte Carlo simulated curves compared to pristine proton Bragg curves. Furthermore, differences between simulations of beams penetrating CT images of the phantom did not agree well with the corresponding experimental differences. The distal falloff widths in CT image-based geometries were underestimated by up to 0.2 cm in water (corresponding to 0.8–1.4 cm in lung tissue), and the peak dose values of pristine proton beams were overestimated by as much as ~35% compared to measured curves or depth-dose curves simulated on the basis of true geometry. The authors demonstrate that these discrepancies were caused by the limited spatial resolution of CT images that served as a basis for dose calculations and lead to underestimation of the impact of the fine structure of tissue heterogeneities. A convolution model was successfully applied to mitigate the underestimation. Conclusions: The results of this study justify further development of models to better represent heterogeneity effects in soft-tissue geometries, such as lung, and to correct systematic underestimation of the degradation of the distal edge of proton doses.

60 APPLIED LIFE SCIENCES↗

The emergence of nonuniform spatiotemporal fractionation schemes within the standard BED model

Purpose: Nonuniform spatiotemporal radiotherapy fractionation schemes, i.e., delivering distinct dose distributions in different fractions can potentially improve the therapeutic ratio. This is possible if the dose distributions are designed such that similar doses are delivered to normal tissues (exploit the fractionation effect) while hypofractionating subregions of the tumor. In this paper, the authors develop methodology for treatment planning with nonuniform fractions and demonstrate this concept in the context of intensity-modulated proton therapy (IMPT). Methods: Treatment planning is performed by simultaneously optimizing (possibly distinct) IMPT dose distributions for multiple fractions. This is achieved using objective and constraint functions evaluated for the cumulative biologically equivalent dose (BED) delivered at the end of treatment. BED based treatment planning formulations lead to nonconvex optimization problems, such that local gradient based algorithms require adequate starting positions to find good local optima. To that end, the authors develop a combinatorial algorithm to initialize the pencil beam intensities. Results: The concept of nonuniform spatiotemporal fractionation schemes is demonstrated for a spinal metastasis patient treated in two fractions using stereotactic body radiation therapy. The patient is treated with posterior oblique beams with the kidneys being located in the entrance region of the beam. It is shown that a nonuniform fractionation scheme that hypofractionates the central part of the tumor allows for a skin and kidney BED reduction of approximately 10%–20%. Conclusions: Nonuniform spatiotemporal fractionation schemes represent a novel approach to exploit fractionation effects that deserves further exploration for selected disease sites.

60 APPLIED LIFE SCIENCES↗

Optimization approaches to volumetric modulated arc therapy planning

Volumetric modulated arc therapy (VMAT) has found widespread clinical application in recent years. A large number of treatment planning studies have evaluated the potential for VMAT for different disease sites based on the currently available commercial implementations of VMAT planning. In contrast, literature on the underlying mathematical optimization methods used in treatment planning is scarce. VMAT planning represents a challenging large scale optimization problem. In contrast to fluence map optimization in intensity-modulated radiotherapy planning for static beams, VMAT planning represents a nonconvex optimization problem. In this paper, the authors review the state-of-the-art in VMAT planning from an algorithmic perspective. Different approaches to VMAT optimization, including arc sequencing methods, extensions of direct aperture optimization, and direct optimization of leaf trajectories are reviewed. Their advantages and limitations are outlined and recommendations for improvements are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Plan averaging for multicriteria navigation of sliding window IMRT and VMAT

Purpose: To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. Methods: The authors show that by taking an appropriately defined average of leaf trajectories of sliding window plans, the authors obtain a sliding window plan whose fluence map is the exact average of the fluence maps corresponding to the initial plans. In the case of static-beam IMRT, this also implies that the dose distribution of the averaged plan is the exact dosimetric average of the initial plans. In VMAT delivery, the dose distribution of the averaged plan is a close approximation of the dosimetric average of the initial plans. Results: The authors demonstrate the method on three Pareto optimal VMAT plans created for a demanding paraspinal case, where the tumor surrounds the spinal cord. The results show that the leaf averaged plans yield dose distributions that approximate the dosimetric averages of the precomputed Pareto optimal plans well. Conclusions: The proposed method enables the navigation of deliverable Pareto optimal plans directly, i.e., interactive multicriteria exploration of deliverable sliding window IMRT and VMAT plans, eliminating the need for a sequencing step after navigation and hence the dose degradation that is caused by such a sequencing step.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct leaf trajectory optimization for volumetric modulated arc therapy planning with sliding window delivery

Purpose: The authors propose a novel optimization model for volumetric modulated arc therapy (VMAT) planning that directly optimizes deliverable leaf trajectories in the treatment plan optimization problem, and eliminates the need for a separate arc-sequencing step. Methods: In this model, a 360° arc is divided into a given number of arc segments in which the leaves move unidirectionally. This facilitates an algorithm that determines the optimal piecewise linear leaf trajectories for each arc segment, which are deliverable in a given treatment time. Multileaf collimator constraints, including maximum leaf speed and interdigitation, are accounted for explicitly. The algorithm is customized to allow for VMAT delivery using constant gantry speed and dose rate, however, the algorithm generalizes to variable gantry speed if beneficial. Results: The authors demonstrate the method for three different tumor sites: a head-and-neck case, a prostate case, and a paraspinal case. The authors first obtain a reference plan for intensity modulated radiotherapy (IMRT) using fluence map optimization and 20 intensity-modulated fields in equally spaced beam directions, which is beyond the standard of care. Modeling the typical clinical setup for the treatment sites considered, IMRT plans using seven or nine beams are also computed. Subsequently, VMAT plans are optimized by dividing the 360° arc into 20 corresponding arc segments. Assuming typical machine parameters (a dose rate of 600 MU/min, and a maximum leaf speed of 3 cm/s), it is demonstrated that the optimized VMAT plans with 2–3 min delivery time are of noticeably better quality than the 7–9 beam IMRT plans. The VMAT plan quality approaches the quality of the 20-beam IMRT benchmark plan for delivery times between 3 and 4 min. Conclusions: The results indicate that high quality treatments can be delivered in a single arc with 20 arc segments if sufficient time is allowed for modulation in each segment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous optimization of dose distributions and fractionation schemes in particle radiotherapy

Purpose: The paper considers the fractionation problem in intensity modulated proton therapy (IMPT). Conventionally, IMPT fields are optimized independently of the fractionation scheme. In this work, we discuss the simultaneous optimization of fractionation scheme and pencil beam intensities.Methods: This is performed by allowing for distinct pencil beam intensities in each fraction, which are optimized using objective and constraint functions based on biologically equivalent dose (BED). The paper presents a model that mimics an IMPT treatment with a single incident beam direction for which the optimal fractionation scheme can be determined despite the nonconvexity of the BED-based treatment planning problem.Results: For this model, it is shown that a small α/β ratio in the tumor gives rise to a hypofractionated treatment, whereas a large α/β ratio gives rise to hyperfractionation. It is further demonstrated that, for intermediate α/β ratios in the tumor, a nonuniform fractionation scheme emerges, in which it is optimal to deliver different dose distributions in subsequent fractions. The intuitive explanation for this phenomenon is as follows: By varying the dose distribution in the tumor between fractions, the same total BED can be achieved with a lower physical dose. If it is possible to achieve this dose variation in the tumor without varying the dose in the normal tissue (which would have an adverse effect), the reduction in physical dose may lead to a net reduction of the normal tissue BED. For proton therapy, this is indeed possible to some degree because the entrance dose is mostly independent of the range of the proton pencil beam.Conclusions: The paper provides conceptual insight into the interdependence of optimal fractionation schemes and the spatial optimization of dose distributions. It demonstrates the emergence of nonuniform fractionation schemes that arise from the standard BED model when IMPT fields and fractionation scheme are optimized simultaneously. Although the projected benefits are likely to be small, the approach may give rise to an improved therapeutic ratio for tumors treated with stereotactic techniques to high doses per fraction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Incorporating uncertainties in respiratory motion into 4D treatment plan optimization

The purpose of this work is to investigate robust 4D optimization techniques which account for respiratory motion uncertainties. Two robust optimization techniques were applied to generate 4D optimized lung treatment plans. The probabilistic optimization approach minimizes the dose variance in the target volume while the worst case optimization minimizes a weighted combination of the nominal and worst case dose distributions which occur in the presence of respiratory motion variation. The two 4D optimization approaches were compared with a margin-based midventilation planning approach in five lung patients. Respiratory motion amplitude and baseline variations were quantified from tidal volume measurements during planning 4D CT acquisition. A similar target coverage was obtained for all three approaches, although the 4D optimization methods tended to be better at sparing the organs at risk. Both robust planning methods are suited for automatic determination of treatment plans which ensure target dose conformality under respiratory motion variations, while minimizing the dose burden of healthy lung tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning

Treatment plans optimized for intensity modulated proton therapy (IMPT) may be very sensitive to setup errors and range uncertainties. If these errors are not accounted for during treatment planning, the dose distribution realized in the patient may by strongly degraded compared to the planned dose distribution. The authors implemented the probabilistic approach to incorporate uncertainties directly into the optimization of an intensity modulated treatment plan. Following this approach, the dose distribution depends on a set of random variables which parameterize the uncertainty, as does the objective function used to optimize the treatment plan. The authors optimize the expected value of the objective function. They investigate IMPT treatment planning regarding range uncertainties and setup errors. They demonstrate that incorporating these uncertainties into the optimization yields qualitatively different treatment plans compared to conventional plans which do not account for uncertainty. The sensitivity of an IMPT plan depends on the dose contributions of individual beam directions. Roughly speaking, steep dose gradients in beam direction make treatment plans sensitive to range errors. Steep lateral dose gradients make plans sensitive to setup errors. More robust treatment plans are obtained by redistributing dose among different beam directions. This can be achieved by the probabilistic approach. In contrast, the safety margin approach as widely applied in photon therapy fails in IMPT and is neither suitable for handling range variations nor setup errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗