Engineering Papers⌕ Search

Engineering topics

Ullom, Joel N

Publications and source records attributed to Ullom, Joel N.

Measurement of ion cascade energies through resolution degradation of alpha particle microcalorimeters

Atomic cascades caused by ions impinging on bulk materials have remained of interest to the scientific community since their discovery by Goldstein in 1902. While considerable effort has been spent describing and, more recently, simulating these cascades, tools that can study individual events are lacking and several aspects of cascade behavior remain poorly known. These aspects include the material energies that determine cascade magnitude and the variation between cascades produced by monoenergetic ions. We have recently developed an alpha particle detector with a thermodynamic resolution near 100 eV full-width-at-half-maximum (FWHM) and an achieved resolution of 1.06 keV FWHM for 5.3 MeV particles. The detector relies on the absorption of particles by a bulk material and a thermal change in a superconducting thermometer. The achieved resolution of this detector provides the highest resolving power of any energy dispersive technique and a factor of 8 improvement over semiconductor detectors. The exquisite resolution can be directly applied to improved measurements of fundamental nuclear decays and nuclear forensics. In addition, we propose that the discrepancy between the thermodynamic and achieved resolution is due to fluctuations in lattice damage caused by ion-induced cascades in the absorber. Hence, this new detector is capable of measuring the kinetic energy converted to lattice damage in individual atomic cascades. This capability allows new measurements of cascade dynamics; for example, we find that the ubiquitous modeling program, SRIM, significantly underestimates the lattice damage caused in bulk tin by 5.3 MeV alpha particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous Thermal Behavior in Microcalorimeter Gamma-Ray Detectors

Improving the resolution of gamma-ray detectors is important for many fields, including determinations of the Lamb shift in atoms with high atomic numbers, nuclear treaty verification, and environmental monitoring. High-purity germanium detectors are currently the tool of choice for precision gamma-ray spectroscopy. The resolution of these detectors is limited to about 500 eV full-width-at-half-maximum at 100 keV by Fano statistics. In comparison, low-temperature microcalorimeters can provide over an order of magnitude improvement in photon resolution. For instance, a gamma-ray microcalorimeter has achieved 25 eV FWHM resolution at 103 keV. These calorimeters consist of two components, a bulk absorber to stop incident gamma rays and a thermometer made from a thin film electrically biased in the superconducting-to-normal phase transition, called a Transition Edge Sensor, or TES. The standard absorber is bulk, superconducting tin. While tin has historically been the best performing absorber, pulse decays in Sn devices are much slower than predicted. We have begun a systematic study of absorber behavior in order to assess and improve response times. This study leverages two capabilities: the ability to microfabricate highly uniform arrays of gamma-ray detectors and the ability to read out many detectors in a single cool-down using SQUID multiplexer circuits. Here, we present two experiments to identify the source of thermal time constants. The first involves varying properties of the Sn absorber including purity, vendor, and crystal grain size. The second examines the role of the other elements in the microcalorimeter assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High rate pulse processing algorithms for microcalorimeters

It has been demonstrated that microcalorimeter spectrometers based on superconducting transition-edge-sensor can readily achieve sub-100 eV energy resolution near 100 keV. However, the active volume of a single microcalorimeter has to be small to maintain good energy resolution, and pulse decay times are normally in the order of milliseconds due to slow thermal relaxation. Consequently, spectrometers are typically built with an array of microcalorimeters to increase detection efficiency and count rate. Large arrays, however, require as much pulse processing as possible to be performed at the front end of the readout electronics to avoid transferring large amounts of waveform data to a host computer for processing. In this paper, they present digital filtering algorithms for processing microcalorimeter pulses in real time at high count rates. The goal for these algorithms, which are being implemented in the readout electronics that they are also currently developing, is to achieve sufficiently good energy resolution for most applications while being (a) simple enough to be implemented in the readout electronics and (b) capable of processing overlapping pulses and thus achieving much higher output count rates than the rates that existing algorithms are currently achieving. Details of these algorithms are presented, and their performance was compared to that of the 'optimal filter' that is the dominant pulse processing algorithm in the cryogenic-detector community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗