Engineering topics
Uin, Janek
Publications and source records attributed to Uin, Janek.
aosccn100 (01)
The cloud condensation nuclei counter measures the concentration of aerosol particles by drawing an air sample through a column with thermodynamically unstable supersaturated water vapor that can condense onto aerosol particles. Particles that are activated, i.e., grown larger in the process, are counted and sized by an optical particle counter (OPC). In this way the CCN measures activated ambient aerosol particle number concentration as a function of supersaturation. ARM operates both one- and two-column versions of the CCN.
ARM: Aerosol Observing System (AOS): Humidograph
Aerosol Observing System (AOS): Humidograph
aoshumidigraph.a1
various temperatures, pressures, RH, flows for the AOS humidograph system. This system controls the humidity of the air that is supplied to the dry and wet nephelometers.
aosnephwet (c1)
The nephelometer measures the total scattering and hemispheric backscattering of aerosol. Nephelometers are deployed in pairs, with one measuring the ambient conditions and the other measuring the scattering as a function of slowly increasing or decreasing relative humidity (RH). The combination can then be used to derive the hygroscopic growth factor as a function of RH: f(RH). The nephelometer is part of the aerosol observing system (AOS).
aosnephdry (c1)
The nephelometer measures the total scattering and hemispheric backscattering of aerosol. Nephelometers are deployed in pairs, with one measuring the ambient conditions and the other measuring the scattering as a function of slowly increasing or decreasing relative humidity (RH). The combination can then be used to derive the hygroscopic growth factor as a function of RH: f(RH). The nephelometer is part of the aerosol observing system (AOS).
ARM: AOS: Ultrahigh Sensitivity Aerosol Spectrometer
AOS: Ultrahigh Sensitivity Aerosol Spectrometer
ARM: Settings and system measurements related to the PNNL-designed humidograph for the AOS
Settings and system measurements related to the PNNL-designed humidograph for the AOS
aosccn1colavg.b1
AOS ccn1col data merged with aoscpcf.b1 or aoscpc.b1 to generate aosccn1colavg.b1
ARM: AOS: Cloud Condensation Nuclei Counter (Single Column), averaged
AOS: Cloud Condensation Nuclei Counter (Single Column), averaged
aosccn1colspectra.b1
ARM Instrument: Cloud Condensation Nuclei Particle Counter
AOS humidified nephelometer, harmonized
AOS humidified nephelometer, harmonized
ARM: AOS: Cloud Condensation Nuclei Counter
AOS: Cloud Condensation Nuclei Counter
ARM: AOS impactor state corrected with nephelometer pressure
AOS impactor state corrected with nephelometer pressure
ARM: AOS Dry Nephelometer 1 Minute Averages
AOS Dry Nephelometer 1 Minute Averages
ARM: AOS Wet Nephelometer 1 Minute Averages
AOS Wet Nephelometer 1 Minute Averages
aosnephwet1m (b1)
The nephelometer measures the total scattering and hemispheric backscattering of aerosol. Nephelometers are deployed in pairs, with one measuring the ambient conditions and the other measuring the scattering as a function of slowly increasing or decreasing relative humidity (RH). The combination can then be used to derive the hygroscopic growth factor as a function of RH: f(RH). The nephelometer is part of the aerosol observing system (AOS).
aosnephdry1m (b1)
The nephelometer measures the total scattering and hemispheric backscattering of aerosol. Nephelometers are deployed in pairs, with one measuring the ambient conditions and the other measuring the scattering as a function of slowly increasing or decreasing relative humidity (RH). The combination can then be used to derive the hygroscopic growth factor as a function of RH: f(RH). The nephelometer is part of the aerosol observing system (AOS).