Engineering Papers⌕ Search

Engineering topics

Tuck, A. F.

Publications and source records attributed to Tuck, A. F..

At least 19 records

Spread of denitrification from 1987 Antarctic and 1988-1989 Arctic stratospheric vortices

Vertical profiles of N2O and NO(y) taken by the ER-2 outside the vortex are used to construct average vertical profiles of F(NO(y)) = NO(y)/(A-N2O), where A is the tropospheric content of N2O three years prior to the measurements. The southern hemisphere had less nitrous oxide in the range 400 less than Theta less than 470 K, by up to 25% relative to the northern hemisphere. F(NO(y)) is the ratio of NOy produced to N2O lost in a stratospheric air mass since entry from the troposphere. The profiles of F(NO(y)) have the following characteristics: (1) Relative to 1991-1992, a year without denitrification inside or outside the vortex, the northern hemisphere in 1988-1989 showed denitrification outside the vortex ranging up to 25% and averaging 17% above Theta = 425 K. (2) Relative to the northern hemisphere in 1991-1992, the southern hemisphere in 1987 showed denitrification outside the vortex ranging up to 32% and averaging 20% above Theta = 400 K. (3) Below Theta = 400 K the southern hemisphere showed enhancements of F(NO(y)) relative to the northern hemisphere in 1991-1992 ranging up to 200% at Theta = 375 K, outside the vortex. Corresponding profiles of residual water, R(H2O) = H2O - 2(1.6 - CH4), are considered and shown to be consistent with those of F(NO(y)) in the sense that they show deficits outside the Antarctic vortex, which was both dehydrated and denitrified, but not outside the 1988-1989 Arctic vortex, which was denitrified but not dehydrated. R(H2O) is the water content of stratospheric air with the contribution from methane oxidation subtracted. Comparison of F(NO(y)) and R(H2O) below 400 K outside the Antarctic vortex leads to the suggetion that dehydration in the Antarctic vortex occurs by the sedimentation of ice crystals large enough to fall out of the stratosphere, whereas denitrification occurs mainly on mixed nitric acid-water crystals which evaporate below the base of the vortex at Theta = 400 K but above the tropopause.

Tuck, A. F.↗

Synoptic interpretation of measurements from HALOE

The degree to which the Southern Hemisphere polar vortex is isolated against horizontal (isentropic) mixing is investigated using data from the Halogen Occultation Experiment (HALOE), U.K. Meteorological Office (UKMO) potential vorticity (PV), and contour advection diagnostics. Measurements of methane and water vapor taken by HALOE during a disturbed period in the Southern Hemisphere springtime (21 September - 15 October 1992) are interpreted in light of the prevailing synoptic meteorology. Daily fields of winds and PV are shown to be essential in the interpretation of the data. A climatological high pressure region is responsible for a distorted vortex, and a substantial 'vortex stripping' event is present, associated with the early stages of vortex breakdown. This leads to significant temporal, zonal, and altitudinal variations in the distribution of tracers. The authors point out the difficulties this presents for the interpretation of solar occultation data, especially with regard to the use of zonal average time series. Longitude-height methane distributions from two days during the period are examined. Both days show substantial variations in abundance around a latitude circle. In particular, the authors investigate HALOE measurements at 77 deg S on 15 October 1992, which indicate an abundance of methane in the height region 600-2000 K (approximately 30-1 mb) that is more typical of midlatitude air. Similar distributions, observed in the 1991 HALOE data, have previously been interpreted as evidence for the penetration of midlatitude air into the vortex. Gradients of potential vorticity and contour advection diagnositcs are employed to examine whether the UKMO winds are consistent with this hypothesis in 1992. Although midlatitude air is able to penetrate poleward of the main jet core by advection processes alone, an essentially intact inner core of vortex air remains, which does not mix to any great extent with air from lower latitudes. The authors show that the high-latitude HALOE abundances that are typical of midlatitude air were observed in a region of extensive filamentation and mixing, rather than within the inner, more isolated, core.

Bithell, M.↗

Stratospheric dryness - Antiphased desiccation over Micronesia and Antarctica

HALOE observations of water vapor and methane during the period 21 September - 15 October 1992 are used to examine the role of Antarctic drying in the lower stratosphere. Zonal mean cross-sections of 2 CH4 + H2O show the probability of transport of Antarctic type dryness to latitudes as distant as 20 deg N, with major water vapor deficits evident between 10 and 100 mb to 10 deg S. Examination of monthly mean tropical 100 mb temperatures and of Antarctic temperatures suggests that the observations are consistent with stratospheric dryness being achieved by the combined effects of tropopause freeze-drying over the Micronesia region during northern winter and drying through the influence of the very low temperatures over Antarctica during southern winter. This paper presents these intriguing new results, and offers a possible explanation.

Tuck, A. F.↗

Intercomparison of haloe and ER-2 aircraft H2O and CH4 observations collected during the second Airborne Arctic Stratospheric Experiment (AASE-II)

HALOE observations of H2O and CH4 are compared with in situ techniques aboard the ER-2 aircraft during the northern winter of 1991/92, in particular for the dates 911208, 920108, 920217, 920222, and 920320 when the spatial coincidences are close, within +/- 1 deg latitude and +/- 12 deg longitude. The results reveal the limitations of comparing high resolution in situ aircraft data with a remote sounding limb scanner. Of the five comparison dates, three had HALOE/ER-2 coincidences which occurred near the edge of the Arctic vortex; the vertical variability in the HALOE results and the horizontal variability in the ER-2 observations on these days show that the vortex edge is not a region where exact agreement can be expected except by chance. On a 4th comparison date, there was substantial overlap away from the vortex edge, although for some species the aircraft data show considerable variability near the coincidence point. On the 5th comparison date, the ER-2 had no overlap in altitude with the lowest HALOE observations; however, a short linear interpolation over about 1 km altitude results in smooth composite profiles. Generally speaking the agreement between HALOE and the ER-2 at overlap altitudes is about 12 percent in the case of water vapor, which shows low horizontal and vertical variability. The agreement for methane, with limited data having altitude overlap, is better than 6 percent.

Tuck, A. F.↗

Polar stratospheric cloud processed air and potential vorticity in the Northern Hemisphere lower stratosphere at mid-latitudes during winter

The present study compares small-scale (less than 100 km) features in ER-2 measurements of ClO, O3, H2O, N2O, and NO(y) outside the lower stratospheric Arctic vortex of 1988-1989 with features on potential vorticity maps from ECMWF. The potential vorticity maps are obtained from T106 analyses and forecasts. Some of the plots were truncated to lower resolution (T63 or T42) which smooths out the finer-scale structure. Comparison of these lower resolution plots shows how much detail is lost by excessive smoothing. It is also evident that the forecast plots lose fine-scale structure due to dissipation in the model resulting mainly from horizontal diffusion. It is concluded that blobs of air on the maps at latitudes between the vortex edge and 25 deg N having potential vorticities characteristic of the vortex did indeed originate from the vortex, but that the real atmosphere is more sharply differentiated than the meteorological analyses, implying that the potential vorticity maps underestimate the amount of peeled-off material.

Tuck, A. F.↗

Observations of denitrification and dehydration in the winter polar stratospheres

It is argued that denitrification of the Arctic stratosphere can be explained by the selective growth and sedimentation of aerosol particles rich in nitric acid. Because reactive nitrogen species moderate the destruction of ozone by chlorine-catalyzed reactions by sequestering chlorine in reservoir species such as ClONO2, the possibility of the removal of reactive nitrogen without dehydration should be allowed for in attempts to model ozone depletion in the Arctic. Indeed, denitrification along with elevated concentrations of reactive chlorine observed in 1989 indicate that the Arctic was chemically primed for ozone destruction without an extended period of temperatures below the frost point, as is characteristic of the Antarctic.

Fahey, D. W.↗

Airborne lidar observations in the wintertime Arctic stratosphere - Ozone

Large-scale distributions of ozone (O3) were measured with an airborne lidar system as part of the 1989 Airborne Arctic Stratospheric Expedition. Measurements of O3 distributions were obtained between January 6 and February 15, 1989, on 15 long-range flights into the polar vortex from the Solar Air Station, Norway. The observed O3 distribution was found to clearly indicate the edge of the polar vortex and to be an effective tracer of dynamical processes in the lower stratosphere. On the last two flights of the expedition, large regions with reduced O3 levels were observed by the lidar inside the polar vortex. Ozone had decreased by as much as 17 percent in the center of these areas, and using the in situ measurements made on the ER-2 aircraft, it was concluded that this decline was due to chemical O3 destruction.

Browell, E. V.↗

Ice saturation at the tropopause observed from the ER-2 aircraft

Ice saturation at or just above the tropopause was frequently observed during the ER-2 vertical profiles over Stavanger (59 deg N) during the Airborne Arctic Stratospheric Expedition (AASE). On occasion, ice saturation extended as much as 500 m above the tropopause. Saturation was not observed over Punta Arenas (53 deg S) during the Airborne Antarctic Ozone Experiment. Saturation extending just above the tropopause was observed at Moffett Field (38 deg N) in winter but not in summer. The top of a thick cirrus layer at the tropopause will be very strongly cooled, and a thin cloud layer at the tropopause will either be strongly heated or cooled depending on the presence of lower level clouds. Some ER-2 data suggests removal of water and nitrogen species from the tropopause.

Murphy, D. M.↗

Redistribution of reactive odd nitrogen in the lower arctic stratosphere

In-situ measurements of total reactive odd nitrogen NO(y), were made from the NASA DC-8 aircraft in the lower arctic stratosphere during the 1989 Airborne Arctic Stratospheric Expedition. Throughout January and February, NO(y) mixing ratios were typically between 0.5 and 3 parts per billion by volume (ppbv) at altitudes between 10 and 12.5 km. During several flights late in the mission, events of unusually light NO(y) occurred with mixing ratios up to 12 ppbv at these altitudes. Simultaneous measurements of N2O, O3, and H2O during these events suggest that large changes in NO(y) are not expected. The elevated NO(y) values are interpreted as a vertical redistribution of NO(y) in the lower stratosphere resulting from gravitational sedimentation of aerosol particles containing HNO3. No evidence of the redistribution of H2O is noted, consistent with observations of denitrification without dehydration higher in the stratosphere.

Huebler, G.↗

A comparison of ER-2 measurements of stratospheric water vapor between the 1987 Antarctic and 1989 Arctic Airborne missions

Vertical profiles of water vapor inside the Antarctic vortex have been compared with those taken outside it over Punta Arenas (53 deg S, 71 deg W). A similar exercise was performed with Arctic vortex profiles and those taken over Stavanger (59 deg N, 6 deg E). Residual water, defined as the stratospheric water vapor mixing ratio with the contribution from methane oxidation subtracted, is also shown as profiles inside and outside the vortex for both missions. The Arctic and Antarctic profiles of water vapor and residual water are compared. Locally dehydrated air was evident both inside and outside the Antarctic vortex, but such dehydration was not evident in and around the Arctic vortex. Arctic profiles of residual water are consistent with nontropical entry for some air.

Kelly, K. K.↗

In situ ozone measurements within the 1987 Antarctic ozone hole from a high-altitude ER-2 aircraft

In situ ozone measurements were made from the ER-2 aircraft during the 1987 Airborne Antarctic Ozone Experiment both inside and outside the ozone hole. Midday measurements from late August until late September during aircraft ascent near 53 deg S latitude indicate no clear temporal trend in ozone mixing ratio but instead reflect the distance of the measurement from the chemically perturbed region. The measurements made within the ozone hole at 72 deg S show altitude-dependent decreases in ozone of 61 percent at a potential temperature of 425 K down to 39 percent at 365 K. Temporal trends are also calculated at various positions relative to the boundary of the chemically perturbed region to locate the region of large ozone decreases and thereby accurately locate the boundary of the ozone hole.

Proffitt, M. H.↗

The Southern Hemisphere lower stratosphere during August and September 1987 - Analyses based on the United Kingdom Meteorological Office Global Model

This paper presents a series of meteorological analyses used to aid the interpretation of the in situ Airborne Antarctic Ozone Experiment (AAOE) observations obtained aboard the ER-2 and DC-8 aircraft and examines the basis and accuracy of the analytical procedure. Maps and sections of meteorological variables derived from the UK Meteorological Office Global Model are presented for ER-2 and DC-8 flight days. It is found that analyzed temperatures and winds are generally in good agreement with AAOE observations at all levels; minor discrepancies were evident only at DC-8 altitudes. Maps of potential vorticity presented on the 428-K potential temperature surface show that the vortex is essentially circumpolar, although there are periods when major distortions are apparent.

Mckenna, D. S.↗

The planning and execution of ER-2 and DC-8 aircraft flights over Antarctica, August and September 1987

The significant ozone loss in the lower stratosphere over Antarctica during recent austral springs was studied by instrumented ER-2 and DC-8 aircraft. Data on the homogeneous gas composition, polar stratospheric clouds, and on tracers for dynamic motion are provided. The mission design is described, the aircraft and their payloads are documented, and the flight tracks are specified.

Tuck, A. F.↗

Dehydration in the lower Antarctic stratosphere during late winter and early spring, 1987

The history of minimum temperatures at 50 and 70 mb is examined from NMC, UK Met O and ECMWF analyses. MSU channel 24 data are similarly inspected. South Pole sonde data are used to calculate saturation humidity mixing ratio as a function of altitude and time throughout 1987. Saturation with respect to ice could be maintained for water mixing ratios of 3.5 ppmv for a period of about 80 days from mid-June to mid-September. Dehydration to mixing ratios of 1 ppmv or less was possible sporadically. Data from the ER-2 flights between 53 S and 72 S are used in conjunction with particle size measurements and air parcel trajectories to demonstrate the dehydration occurring over Antarctica. Water mixing ratios at the latitude of Punta Arens (53 S), in conjunction with tracer measurements and trajectory analysis, show that at potential temperatures from about 325 to 400 K, the dryness (less than 3 ppmv) had its origin over Antarctica rather than in the tropics. Water mixing ratios within the Antarctic vortex varied from 1.5 to 3.8 ppmv, with a strong isentropic gradient being evident in the region of high potential vorticity gradients.

Kelly, K. K.↗

A chemical definition of the boundary of the Antarctic ozone hole

A program designed to study the Antarctic ozone hole using ER-2 high-altitude and DC-8 aircraft was conducted out of Punta Arenas, Chile during August 17-September 22, 1987. Graphs are presented of ozone and chlorine monoxide when crossing the boundary of the chemically perturbed region on August 23 and on September 21. Interpretations of ClO, H2O, and N2O measurements are presented, indicating ongoing diabetic cooling and advective poleward transport across the boundary.

Proffitt, M. H.↗

Indicators of transport and vertical motion from correlations between in situ measurements in the Airborne Antarctic Ozone Experiment

Analysis of small-scale structure in the in situ measurements made from the ER-2 during the Airborne Antarctic Ozone Experiment shows the existence of a region at the boundary of the chemiclly perturbed region where the mixing ratios and small-scale structure of trace gases are influenced by transport across the boundary. This transition region is characterized by horizontal interchange and vertical layering of air parcels from within and outside of the chemically perturbed region and negative small-scale correlations between ClO and ozone. The horizontal transport in this region creates large surface areas between dissimilar air masses, providing the potential for substantial mixing. Correlations between ClO and O3 show that the transition region extends to 2-4 deg of latitude to either side of the boundary of the chemically perturbed region. A + or - 4-deg-wide transition region would contain nearly as much air as the chemically perturbed region proper. Analysis of water vapor and nitrous oxide data suggests that diabatic descent is associated with dehydration. This could be caused by strong radiative cooling of those polar stratospheric clouds in which enough water condenses for the particles to fall and dehydrate the air.

Murphy, D. M.↗

Synoptic and chemical evolution of the Antarctic vortex in winter and spring, 1987

The dynamical evolution of the vortex at least up to 50 mb is dominated by synoptic scales in the troposphere. In particular, there is a clear response when poleward extension of tropospheric anticyclones from latitudes of 40 and 50 S to 70 and 80 S occurs. This response is evident in isentropic potential vorticity maps, TOMS ozone fields and SAM II polar stratospheric clouds. An important feature of the high latitude Southern Hemisphere lower stratosphere is a transition at potential temperatures in the 390 to 400 K range. This transition, the vortopause, is clearly marked in aircraft profiles of O3, H2O, N2O and ClO at latitudes 68 to 72 S near the Antarctic peninsula, and also cross-sections of potential vorticity and potential temperature; above it, the isopleths are more closely spaced than below it. The aircraft measurements of H2O, O3, NO sub y, N2O, ClO, and whole air data are examined in material coordinates, theta and P sub theta, backed up by trajectory analysis. The evolution of the chemical mixing ratios is examined in these coordinates as a function of time from mid-August to late September. Conclusions are drawn about the rates of change and their causes. The meteorological and aircraft data are examined for evidence of the following kinds of motion with respect to the vortex: ingress of air aloft, subsidence, peeling off of air to lower latitudes, and folding of the vortopause. Conclusions are presented regarding the evidence for a chemical sink of ozone above and below theta = 400 K, and whether the vortex has a mass flow through it, or if the chemical sink operates on a fixed mass of air. Implications for mid-latitudes are briefly considered in the light of the conclusions.

Tuck, A. F.↗

Dehydration in the lower Antarctic stratosphere in late winter and spring

The history of minimum temperatures at 50 and 70 mb is examined from NMC, UK Met 0 and ECMWF analyses. MSU channel 24 data are similarly inspected. South Pole sonde data are used to calculate saturation humidity mixing ratio as a function of altitude and time throughout 1987. Saturation with respect to ice could be maintained for water mixing ratios of 3.5 ppmv for a period of about 80 days from mid-June to mid-September. Dehydration to mixing ratios of 1 ppmv or less was possible sporadically. Data from the ER-2 flights between 53 S and 72 S are used in conjunction with particle size measurements and air parcel trajectories to demonstrate the dehydration occurring over Antarctica. Water mixing ratios at the latitude of Punta Arenas (53 S), in conjunction with tracer measurements and trajectory analysis, show that at potential temperatures from about 325 to 400 K, the dryness (less than 3 ppmv) had its origin over Antarctica rather than in the tropics. Water mixing ratios within the Antarctic vortex varied from 1.5 to 3.8 ppmv, with a strong isentropic gradient being evident in the region of high potential vorticity gradients.

Kelly, K. K.↗