Acoustic Injectors for Drop-On-Demand Serial Femtosecond Crystallography
Not Available
Engineering topics
Publications and source records attributed to Tsai, Yingssu.
Not Available
Abstract not provided
Higher throughput methods to mount and collect data from multiple small and radiation-sensitive crystals are important to support challenging structural investigations using microfocus synchrotron beamlines. Furthermore, efficient sample-delivery methods are essential to carry out productive femtosecond crystallography experiments at X-ray free-electron laser (XFEL) sources such as the Linac Coherent Light Source (LCLS). To address these needs, a high-density sample grid useful as a scaffold for both crystal growth and diffraction data collection has been developed and utilized for efficient goniometer-based sample delivery at synchrotron and XFEL sources. A single grid contains 75 mounting ports and fits inside an SSRL cassette or uni-puck storage container. The use of grids with an SSRL cassette expands the cassette capacity up to 7200 samples. Grids may also be covered with a polymer film or sleeve for efficient room-temperature data collection from multiple samples. New automated routines have been incorporated into the Blu-Ice / DCSS experimental control system to support grids, including semi-automated grid alignment, fully automated positioning of grid ports, rastering and automated data collection. Specialized tools have been developed to support crystallization experiments on grids, including a universal adaptor, which allows grids to be filled by commercial liquid-handling robots, as well as incubation chambers, which support vapor-diffusion and lipidic cubic phase crystallization experiments. Experiments in which crystals were loaded into grids or grown on grids using liquid-handling robots and incubation chambers are described. As a result, crystals were screened at LCLS-XPP and SSRL BL12-2 at room temperature and cryogenic temperatures.
New software has been developed for automating the experimental and data-processing stages of fragment-based drug discovery at a macromolecular crystallography beamline. A new workflow-automation framework orchestrates beamline-control and data-analysis software while organizing results from multiple samples. AutoDrug is software based upon the scientific workflow paradigm that integrates the Stanford Synchrotron Radiation Lightsource macromolecular crystallography beamlines and third-party processing software to automate the crystallography steps of the fragment-based drug-discovery process. AutoDrug screens a cassette of fragment-soaked crystals, selects crystals for data collection based on screening results and user-specified criteria and determines optimal data-collection strategies. It then collects and processes diffraction data, performs molecular replacement using provided models and detects electron density that is likely to arise from bound fragments. All processes are fully automated, i.e. are performed without user interaction or supervision. Samples can be screened in groups corresponding to particular proteins, crystal forms and/or soaking conditions. A single AutoDrug run is only limited by the capacity of the sample-storage dewar at the beamline: currently 288 samples. AutoDrug was developed in conjunction with RestFlow, a new scientific workflow-automation framework. RestFlow simplifies the design of AutoDrug by managing the flow of data and the organization of results and by orchestrating the execution of computational pipeline steps. It also simplifies the execution and interaction of third-party programs and the beamline-control system. Modeling AutoDrug as a scientific workflow enables multiple variants that meet the requirements of different user groups to be developed and supported. A workflow tailored to mimic the crystallography stages comprising the drug-discovery pipeline of CoCrystal Discovery Inc. has been deployed and successfully demonstrated. This workflow was run once on the same 96 samples that the group had examined manually and the workflow cycled successfully through all of the samples, collected data from the same samples that were selected manually and located the same peaks of unmodeled density in the resulting difference Fourier maps.
Lattice-translocation or crystal order-disorder phenomena occur when some layers or groups of molecules in a crystal are randomly displaced relative to other groups of molecules by a discrete set of vectors. In previous work, the effects of lattice translocation on diffraction intensities have been corrected by considering that the observed intensities are the product of the intensities from an ideal crystal (lacking disorder) multiplied by the squared magnitude of the Fourier transform of the set of translocation vectors. Here, the structure determination is presented of carboxysome protein CsoS1C from Halothiobacillius neapolitanus in a crystal exhibiting a lattice translocation with unique features. The diffraction data are fully accounted for by a crystal unit cell composed of two layers of cyclic protein hexamers. The first layer is fully ordered (i.e. has one fixed position), while the second layer randomly takes one of three alternative positions whose displacements are related to each other by threefold symmetry. Remarkably, the highest symmetry present in the crystal is P3, yet the intensity data (and the Patterson map) obey 6/m instead of {bar 3} symmetry; the intensities exceed the symmetry expected from combining the crystal space group with an inversion center. The origin of this rare phenomenon, known as symmetry enhancement, is discussed and shown to be possible even for a perfectly ordered crystal. The lattice-translocation treatment described here may be useful in analyzing other cases of disorder in which layers or groups of molecules are shifted in multiple symmetry-related directions.