Engineering PapersSearch

Engineering topics

Truong, Tuan

Publications and source records attributed to Truong, Tuan.

WFIRST Low Order WaveFront Sensing and Control (LOWFS/C) performance on line-of-sight disturbances from multiple reaction wheels

In this paper we will describe the LOWFS/C LoS performance test in which the injected LoS disturbances are derived from all six reaction wheels on WFIRST, each with an independent varying wheel speed profile modeled for a typical coronagraph observational scenario. We will describe the LoS disturbances profile and testbed implementation approach. We will present the LOWFS/C LoS feedback and feed forward loops testbed performance under these realistic LoS disturbances in which we have demonstrated the LoS control that meets the CGI requirement.

Shelton, Chris

WFIRST Low Order Wavefront Sensing and Control Testbed Performance under Flight Like Photon Flux

To maintain the required performance for the WFIRST Coronagraph Instrument (CGI) in a realistic space environment, a Low Order Wavefront Sensing and Control (LOWFS/C) subsystem is necessary. The WFIRST CGI LOWFS/C subsystem would use the Zernike wavefront sensor, which has the phase-shifting disk combined with the coronagraph’s focal plane mask, to sense the low-order wavefront drift and line-of-sight (LoS) error using the rejected starlight. The dynamic tests on JPL’s on the Occulting Mask Coronagraph (OMC) Testbed have demonstrated that LOWFS/C can maintain coronagraph contrast to better than 10-8 in presence of WFIRST-like line of sight and low order wavefront disturbances in both Shaped Pupil Coronagraph (SPC) and Hybrid Lyot Coronagraph (HLC) modes. However, the previous dynamic tests have been done using a bright source with photon flux equivalent to stellar magnitude of Mv = -3.5. The LOWFS/C technology development continues on the OMC testbed especially in evaluating and improving the LOWFS/C performance under the realistic photon flux that is equivalent to WFIRST Coronagraph target stars. Our recent testbed tests have demonstrated that the LOWFS/C can work cohesively with the stellar light suppression wavefront control, which brings broad band coronagraph contrast from 1x10-6 to 6x10-9, while LOWF/C is simultaneously suppressing the WFIRST like LoS and low order wavefront drift disturbances on a source that photon flux is equivalent to a Mv = 2 star. This demonstration mimics the CGI initial dark hole establish process on a bright reference star. We also demonstrated on the testbed that LOWFS/C can maintain the coronagraph contrast by suppressing the WFIRST like line-of-sight disturbances on a fainter Mv = 5 star. This mimics scenario of CGI science target observations. In this paper we will present the recent testbed results on LOWFS/C LoS loops and low order wavefront error correction loop performance on the flight like photon flux.

Truong, Tuan

Dynamic Testbed Demonstration of WFIRST Coronagraph Low Order Wavefront Sensing and Control (LOWFS/C)

To maintain the required performance of WFIRST Coronagraph in a realistic space environment, a Low Order Wavefront Sensing and Control (LOWFS/C) subsystem is necessary. The LOWFS/C uses a Zernike wavefront sensor (ZWFS) with the phase shifting disk combined with the starlight rejecting occulting mask. For wavefront error corrections, WFIRST LOWFS/C uses a fast steering mirror (FSM) for line-of-sight (LoS) correction, a focusing mirror for focus drift correction, and one of the two deformable mirrors (DM) for other low order wavefront error (WFE) correction. As a part of technology development and demonstration for WFIRST Coronagraph, a dedicated Occulting Mask Coronagraph (OMC) testbed has been built and commissioned. With its configuration similar to the WFIRST flight coronagraph instrument the OMC testbed consists of two coronagraph modes, Shaped Pupil Coronagraph (SPC) and Hybrid Lyot Coronagraph (HLC), a low order wavefront sensor (LOWFS), and an optical telescope assembly (OTA) simulator which can generate realistic LoS drift and jitter as well as low order wavefront error that would be induced by the WFIRST telescope’s vibration and thermal changes. In this paper, we will introduce the concept of WFIRST LOWFS/C, describe the OMC testbed, and present the testbed results of LOWFS sensor performance. We will also present our recent results from the dynamic coronagraph tests in which we have demonstrated of using LOWFS/C to maintain the coronagraph contrast with the presence of WFIRST-like line-of-sight and low order wavefront disturbances.

Zhou, Hanying

Narrowband Rejection of Reaction Wheel and Environmental Disturbances for the WFIRST OMC Testbed

The Wide Field Infrared Survey Telescope (WFIRST) is a NASA observatory with two scientific instruments. The first is the Wide Field Instrument (WFI) designed to perform wide field imaging and surveys of the near infrared (NIR) sky. The second is a coronagraph (CGI) that will enable astronomers to detect and measure properties of planets in other solar systems. The coronagraph requires 0.5 milli-arcsecond (mas) RMS pointing per axis of the line of sight (LOS) to achieve a contrast of 1x10-9. This paper discusses the approach used for achieving this level of pointing performance on the occulting mask coronagraph (OMC) testbed at JPL. This testbed uses a low-order wavefront sensing (LOWFS) camera and fast steering mirror (FSM) to suppress injected LOS jitter and environmental LOS jitter. The injected jitter includes representative broadband spacecraft attitude control system (ACS) LOS motion and tonal LOS jitter caused by the reaction wheel assemblies (RWA). The environmental jitter includes thermal LOS variations and harmonics of the line noise. The LOWFS camera uses high flux from the obscured science target to achieve high rate measurements of the LOS. These measurements are augmented with fictitious RWA tachometer information and an estimate of the line noise frequency. A LOS servo using a combination of feedback and feedforward control is used in the testbed to compensate for all of the disturbance sources and to mitigate jitter caused by in-band camera noise. The feedforward uses a novel robust least mean squares (RLMS) filter algorithm to reject the RWA and line frequency tones. High fidelity models of the sensors, disturbances and actuator are presented in this paper. These models were developed as part of a simulation of the LOS control system. Performance results from the hardware testbed at the Jet Propulsion Laboratory (JPL) are discussed in this paper.

Shields, Joel

Low Order Wavefront Sensing and Control for WFIRST Coronagraph

To maintain the required WFIRST Coronagraph starlight suppression performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C uses the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading on the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST Coronagraph and describe the WFIRST Coronagraph LOWFS function, its design, and modeled performance. We will present experimental results on a dedicated LOWFS/C testbed that show that the LOWFS/C subsystem not only can sense pointing errors better than 0.2 mas but has also experimentally demonstrated closed loop pointing error suppression with residuals better than 0.4 mas rms per axis for the vast majority of observatory reaction wheel speeds.

wavefront sensing and control

Low order wavefront sensing and control for WFIRST coronagraph

To maintain the required WFIRST Coronagraph starlight suppression performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C uses the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading on the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST Coronagraph and describe the WFIRST Coronagraph LOWFS function, its design, and modeled performance. We will present experimental results on a dedicated LOWFS/C testbed that show that the LOWFS/C subsystem not only can sense pointing errors better than 0.2 mas but has also experimentally demonstrated closed loop pointing error suppression with residuals better than 0.4 mas rms per axis for the vast majority of observatory reaction wheel speeds.

Wilson, Dan

Low Order Wavefront Sensing and Control for WFIRST-AFTA Coronagraph

To maintain the required WFIRST Coronagraph performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C use s the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading of the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST -AFTA Coronagraph. We will describe LOWFS/C's Zernike wavefront sensor concept and WFIRST LOWFS/C control design. We will present an overview of our analysis and modeling results on the Zernike wavefront sensor, the line -of-sight jitter suppression loop performance, as well as the low order wavefront error correction with the coronagraph's deformable mirror. In this paper we will also report the LOWFS/C testbed design and the preliminary in-air test results, which show a very promising performance of the Zernike wavefront sensor and FSM feedback loop.

exoplanets

Mid-IR interferometric nulling for TPF

By the middle of 2006, the Interferometry Technology development program for NASA’s Terrestrial Planet Finder (TPF) Mission has the goal of demonstrating deep and stable interferometric nulling of broadband Mid-IR thermal radiation under conditions that are traceable to the expected on-orbit conditions. Specifically, the task is to demonstrate null levels of 10 to the negative 6 power, with a 50% BW centered at 10 um, with null stabilities of 10 to the negative 7 power all at cryogenic temperatures for observational periods of a couple of hours. The Achromatic Nulling activity at JPL addresses this concern in two testbeds: the warm nulling testbed and the cryonulling testbed. The warm nulling testbed will demonstrate the physics of nulling broadband thermal sources in an environment that is conducive to efficient research. We’ll explore nulling techniques, optical-mechanical alignment methods, motion control, and path-length metrology for a single beam interferometer, as well as preliminary planet detection techniques. Ultimate nulling capabilities under conditions that are more flight-like will be demonstrated in cryogenic nulling testbed. Knowledge gained from operation at room temperature will be applied to the cryongenic experiment where we face the additional challenges of extreme temperatures, cryongenic actuators, component survivability and fluxes that are within an order of magnitude of expected flux levels on orbit. Concurrently, we will develop a low flux mid-IR camera that will allow us to measure the nulls at these faint photon fluxes. This talk will review this development activity and will include recent nulling experimental results and plans for future work.

Vasisht, Gautam

Automated Static Culture System Cell Module Mixing Protocol and Computational Fluid Dynamics Analysis

This report is a documentation of a fluid dynamic analysis of the proposed Automated Static Culture System (ASCS) cell module mixing protocol. The report consists of a review of some basic fluid dynamics principles appropriate for the mixing of a patch of high oxygen content media into the surrounding media which is initially depleted of oxygen, followed by a computational fluid dynamics (CFD) study of this process for the proposed protocol over a range of the governing parameters. The time histories of oxygen concentration distributions and mechanical shear levels generated are used to characterize the mixing process for different parameter values.

Kleis, Stanley J.