Engineering Papers⌕ Search

Engineering topics

Trojanowski, Rebecca

Publications and source records attributed to Trojanowski, Rebecca.

Enabling residential heating decarbonization through hydronic low-temperature thermal distribution using forced-air assistive devices

Space heating represents approximately one-tenth of the United States’ energy use and has a breadth of potential for emission reduction. An element of space heating, hydronic heat distribution methods, use water supply temperatures up to 82.2 °C (180 °F). However, this operating temperature can be incompatible with high-efficiency heat generation systems, which typically provide heating temperatures of up to 60 °C (140 °F). In this work, a low-cost retrofit solution is developed using experimentally validated computational tools by incorporating an airflow distributor that preferentially directs the airflow from a fan to enhance heat transfer over the finned-tube heat exchanger found in conventional baseboards. The same heat output of traditional baseboard heat distribution systems operating at higher water supply temperatures (71.1 – 82.2 °C) can also be achieved at lower temperatures (≤60 °C). Specifically, results indicate that the technology can produce more than a 46.7% improvement in the heat transfer output at temperatures as low as 60 °C (140 °F), effectively matching the same output range achieved by 71.1 – 82.2 °C (160–180 °F) water supply temperatures. An important benefit of this solution is that it utilizes the existing infrastructure as opposed to requiring the replacement of the entire distribution system. Additionally, this technology enables existing building infrastructure to be coupled with newer, high-efficiency heating systems such as condensing boilers, solar-thermal systems, and geothermal/air-to-water heat pumps that may produce lower water supply temperatures (60 °C). A geospatially resolved techno-economic and environmental analysis is completed and presented to further understand the equivalent carbon footprint of enabling higher efficiency heat generation systems with the improved efficiency heat distribution system disclosed. Using 2021 grid-average emission factors, an emission reduction of up to a 67.5% decrease (2658 kgCO 2 /yr) for a single-family home, depending on state and climate region, could be realized by replacing a traditional natural gas-fired boiler with an air-to-water heat pump coupled to the same high-temperature heat distribution system along with the low-cost retrofit solution. A complete CO 2 emission reduction of 6688 kgCO 2 /yr, depending on state and climate region, could be realized if all electricity is further renewably sourced. Thus, this study provides a possible pathway towards enabling the reduction of operational emissions in space heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Innovative Air-Source Heat Pumps for Cold-Climate Heating Applications

Air-source heat pumps (ASHPs) have historically found application in milder climates in the United States (US). Their application in cold climates has been hindered by reduced performance as outdoor temperatures fall below freezing and the need for backup or auxiliary electric resistance heaters to meet peak heating loads. Recent advances in cold-climate air-source heat pumps (ccASHPs) with features such as variable-speed compressors, multistage systems, and highly optimized thermal design have improved performance by increasing the coefficient of performance (COP), low-ambient-temperature capacity, and heating seasonal performance factor (HSPF) dramatically. Despite their benefits, ccASHPs are still not widely prescribed for cold climate conditions. This is due in part to a lack of verified, demonstrated performance and analysis in cold climates. Ultimately, high-efficiency ccASHPs play a key role in emerging energy/grid renovation efforts in addition to their potential energy savings and avoided carbon emissions, but their actual performance in various cold climate field settings must be better understood. The primary objective of this project was to measure the in-field performance of variable-capacity air-source heat pumps in cold climates with the goal of enabling the development of field-based performance maps. Specifically, the study looked at how the heat pumps operated in the field, the frequency of cycling, the frequency of defrost events, and the time spent in each mode of operation. The results are intended to be used by DOE to inform research and development of energy-efficient equipment and to develop guidelines for optimizing primary energy savings when using air-source heat pumps in heating-dominated regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ARM FY2024 Aerosol Operations Plan

The Atmospheric Radiation Measurement user facility (ARM) deploys a suite of aerosol and trace gas (further mentions of aerosols will assume inclusion of trace gases) instrumentation at each of ARM's observatories. ARM currently deploys five Aerosol Observing Systems, one each at: Southern Great Plains (SGP); Eastern North Atlantic (ENA); ARM Mobile Fabilities (AMFI 1, 2, and 3). Aerosol measurements at ARM’s North Slope of Alaska (NSA) observatory have historically been made by the National Oceanic and Atmospheric Administration (NOAA) and provided to ARM through a collaboration. As ARM’s support for aerosol instrumentation increases, it is important for ARM to communicate plans and priorities for aerosol measurements to the community to maximize the benefit and planning around scientific activities and to advance confidence in ARM’s aerosol measurements. ARM will develop a yearly aerosol operations plan for the upcoming fiscal year (October 1-September 30) starting with FY24. This plan will be open and available through the ARM aerosol instrument webpages and will include: Review of the previous activities since the last plan (in this case, 2018); Planned activities and their priorities for the upcoming FY; Calibration timing and efforts; Planned activities for data products and value-added products (VAP).

54 ENVIRONMENTAL SCIENCES↗

Wood Heater Design Challenge Workshop Report

To support the United States Department of Energy (DOE) Bioenergy Technologies Office’s (BETO) goal of advancing residential wood heating technologies, Brookhaven National Laboratory (BNL), Lawrence Berkeley National Laboratory (LBNL), and the Alliance for Green Heat (AGH) hosted the fifth Wood Heater Design Challenge (WHDC). The Challenge consists of three virtual workshops and a Technology Slam aimed at inspiring and advancing the next generation of residential wood heaters. With an estimated 12.5 million homes in the United States using wood or pellets for space heating, this challenge stands to create a significant impact on the environmental footprint of domestic heating. This report provides a summary of the activities and outcomes from the three virtual workshops held in January, March, and April of 2022. The goal of the workshops was to bring together stakeholders from across the world to discuss research and development (R&D) challenges and opportunities for advancing residential wood heaters in the United States. The workshops focused on three topics: 1. Advances in wood heater design and technology; 2. Advances in instrumentation used for wood heater testing and field data collection; and 3. Adoption of new wood heater technology and integration with other renewables. Each workshop had more than 100 participants each day which included wood heater manufacturers, researchers, academics, government agencies, and policy makers. Overall, a clear message was presented that collaborative input from experts at air quality agencies, industry, academic institutions, and non-profits is necessary to ensure that wood heating technology continues as a mainstream renewable energy option in our changing energy landscape and to facilitate innovative technology solutions. Participants also provided insights and recommendations that may help guide future R&D investments.

09 BIOMASS FUELS↗

Black carbon emissions from modern automated cordwood stoves for space heating

Wood burning stove design is improving as regulation become stricter for particulate matter emissions. Here, this study describes results of black carbon (BC) emissions from three modern automated wood stoves when tested in common failure modes using a test protocol that included cold-starts, high and low fuel loading densities, and use of overly large pieces of fuel. Emission sampling was performed using a dilution sampling system in tandem with an aethalometer to measure BC with high time resolution. Results show that the time-weighted average BC emission rates were 0.91, 4.30, and 1.74 g/h for the three stoves tested (A, B, and C respectively), the values, both higher and lower than the United States 2020 certification test emission limit of 2.5 g/h. The results demonstrate good performance overall, given the rigorous nature of the testing protocol used. The aethalometer data showed that the performance was relatively poor during cold-start, when the fuel was ignited and combusted without a coalbed, and when stoves failed to optimize air delivery due to specific loading and output conditions. During the cold-start test section, the average BC emission rate was seven times higher than the overall average for Stove A, 10 times above the average for Stove B, and two times above the average emission rate for Stove C. Calculations of the Average Angstrom Absorption Exponent (AAE) of the exhaust aerosol showed little correlation with BC concentration. The results show that automation results in a quantifiable reduction in particular BC emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wood combustion nanoparticles emitted by conventional and advanced technology cordwood boilers, and their interactions in vitro with human lung epithelial monolayers

Biomass-burning boilers and stoves are widely used in many parts of the world, producing combustion emissions linked with health risks. Here, combustion emission nanoparticles (NPs) were collected from four representative wood burning boilers using oak cordwood at specific times in the burn cycle. The morphology and composition of the NPs was characterized using transmission electron microscopy and energy dispersive X-ray analysis. To determine the degree of NP cytotoxicity with human lung tissue, the combustion NPs were introduced to incubated lung bronchial epithelial monolayers (NCI-H292) in vitro at doses of 0.1×10 -6 and 3.0×10 -6 kg/L for 2 and 4 h. Histochemical analysis showed that cell death increased by a factor of 3.5 for both doses after 4 h when compared to the control. Ultrapure NPs prepared by wet chemical methods were also introduced to the epithelial lung cells for similar doses and exposure times and the cultures exhibited significantly reduced mortality. Electron microscopy was used to study the mechanism of cell mortality for the synthesized and combustion-based NPs by examining how the NP byproducts interacted with individual cell organelles. It was found that cell survival was strongly correlated with the absence of contaminants (salts, heavy metals, poly aromatic hydrocarbons) associated with the NPs entering the cells. Synthesized NPs consisting of pure carbon were relatively well tolerated and could be excreted without damaging the cell ultrastructure. Thus, careful removal of extraneous contaminants by controlling the burn cycle with a catalyst is essential to minimize the health and environmental effects of wood biofuel combustion. In better words, optimized advanced technology wood-burning boilers and stoves can provide a CO 2 -neutral energy source and significantly contribute to a future where fossil fuels have a reduced role.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 3: Optical properties of black and brown carbon emissions

Residential biomass combustion is a source of carbonaceous aerosol. Inefficient combustion, particularly of solid fuels produces large quantities of black and brown carbon (BC and BrC). These particle types are important as they have noted effects on climate forcing and human health. One method of measuring these quantities is by measurement of aerosol light-absorption and scattering, which can be performed using an aethalometer and nephelometer, respectively. These instruments are widely deployed in the study of ambient air and are frequently used in air quality modeling and source apportionment studies. In this study, we will describe (1) a method for measuring primary BC and BrC emissions from two residential log-fired wood hydronic heaters and (2) the BC and BrC emission from these devices over a wide range of operating conditions, such as cold-starts, warm-starts, four different levels of output ranging from 15% to 100% maximum rated output, and periods of repeated cycling. The range in flue-gas BC concentrations, measured using an aethalometer at the 880 nanometer (nm) wavelength, were between 5.09 × 10 2 and 2.24 × 10 4 micrograms per cubic meter (µg/m 3 ) while the scattering coefficient of the flue-gas, measured by a nephelometer at 880 nm, ranged between 2.20 × 10 3 and 8.56 × 10 5 inverse megameters (Mm –1 ). The BrC concentrations, measured using the 370 nm wavelength of an aethalometer, were between 9.10 × 10 1 and 3.56 × 10 4 µg/m 3 . The calculated Angstrom Absorption Exponent (AAE) of the flue-gas aerosol ranged between 1.54 and 3.63. Performing a comparison between the measured BC concentration and an external particulate matter (PM) concentration showed that overall BC makes up roughly a quarter of the PM emitted by either of the two appliances. Further for both appliances, the cold-start and the test phase immediately following it had the highest BC and BrC concentrations, the highest measured scattering coefficient, as well as a low AAE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 2: Particle number and size

The use of wood as a fuel for home heating is a concern from an environmental health and safety perspective as biomass combustion appliances emit high concentrations of particulate matter. Wood burning significantly contributes to wintertime particulate matter concentrations in many states in the northern United States. Of particular concern are outdoor wood-fired hydronic heaters. These devices are concerning as they tend to have very large combustion chambers and typical use patterns can result in long periods of low output, which result in an increased particulate matter emission rate relative to high heat output operating conditions. In this study, the performance of two hydronic heaters operating under different combustion conditions, including four different heat output categories approximately corresponding to categories I–IV denoted in Environmental Protection Agency Method 28 Outdoor Wood-fired Hydronic Heaters, and during start-up and reloading events were investigated. Measurements of flue gas particulate number concentration and size for particles with aerodynamic diameters between 0.006 and 10 µm were made using a dilution sampling system. The measured particle number concentration in the flue gas was between 0.71 and 420 million particles per cubic centimeter and was dependent on fuel loading and heat output. For each hydronic heater tested, the highest average particle concentration was found at the beginning of each test during the cold-start condition. Additionally, the majority of the particles had aerodynamic diameters less than 0.100 µm (particles of this size made up between 64% and 97% of all particles) and less than 1% of all particles had aerodynamic diameters greater than 1 µm for all phases. For particles in the accumulation mode, between 0.100 and 1 µm, the mean particle diameter was dependent on fuel loading and heat output.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

aospsap3w.b1

AOS PSAP3W b1 datastream

54 ENVIRONMENTAL SCIENCES↗

aosso2.b1

Harmonized (some QC added) aosso2 datastream

54 ENVIRONMENTAL SCIENCES↗