Engineering Papers⌕ Search

Engineering topics

Tripathi, M.

Publications and source records attributed to Tripathi, M..

At least 37 records · Page 2

On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors

Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT replacements. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. Here, no dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a tagged source of Pb-206 nuclei

There is a particular class of unavoidable backgrounds that plague low-background experiments and rare event searches, particularly those searching for nuclear recoil event signatures: decaying daughters of the 238 U nuclear decay chain, which result from radon plate-out on detector materials. One such daughter isotope, 210 Po, undergoes α-decay and produces a recoiling 103 keV 206 Pb nucleus. In this study, to characterize this important background in the context of noble element detectors, we have implemented a triggered source for these 206 Pb recoils in a dual-phase xenon time projection chamber (Xe TPC) within the Davis Xenon R&D testbed system (DAX). By adhering 210 Po to the surface of a PIN diode and electrically floating the diode on the cathode of the TPC, we tag the α signals produced in the PIN diode and trigger on the correlated nuclear recoils in the liquid xenon (LXe). Lastly, we discuss our methods for 210 Po deposition, electronic readout of the PIN diode signals at high voltage, and analysis methods for event selection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position reconstruction in LUX

The (x, y) position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe the response of the PMTs. The reconstruction was assessed with calibration data including 83m Kr (releasing a total energy of 41.5 keV) and 3 H (β - with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV). Within the detector's fiducial volume, the reconstruction has achieved an (x, y) position uncertainty of σ = 0.82 cm and σ = 0.17 cm for events of only 200 and 4,000 detected electroluminescence photons respectively. Such signals are associated with electron recoils of energies ~0.25 keV and ~10 keV, respectively. Lastly, the reconstructed position of the smallest events with a single electron emitted from the liquid surface (22 detected photons) has a horizontal (x, y) uncertainty of 2.13 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultralow energy calibration of LUX detector using Xe 127 electron capture

We report an absolute calibration of the ionization yields (Q y ) and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy 127 Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of weakly interacting massive particles. The sequence of gamma-ray and x-ray cascades associated with 127 I deexcitations produces clearly identified two-vertex events in the LUX detector. We observe the K-(binding energy, 33.2 keV), L-(5.2 keV), M-(1.1 keV), and N-(186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. In conclusion, the N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil in situ measurements that have been explored in liquid xenon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

83⁢m Kr calibration of the 2013 LUX dark matter search

LUX was the first dark matter experiment to use a 83⁢m Kr calibration source. In this study, we describe the source preparation and injection. We also present several 83⁢m Kr calibration applications in the context of the 2013 LUX exposure, including the measurement of temporal and spatial variation in scintillation and charge signal amplitudes, and several methods to understand the electric field within the time projection chamber.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D modeling of electric fields in the LUX detector

This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data to search for weakly interacting massive particles (WIMPs) during two periods. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's active volume. This caused electric field variations in the detector in time, depth and azimuth, generating an electrostatic radially-inward force on electrons on their way upward to the liquid surface. To map this behavior, 3D electric field maps of the detector's active volume were generated on a monthly basis. This was done by fitting a model built in COMSOL Multiphysics to the uniformly distributed calibration data that were collected on a regular basis. The modeled average PTFE charge density increased over the course of the exposure from -3.6 to -5.5 μC/m 2 . Here, from our studies, we deduce that the electric field magnitude varied locally while the mean value of the field of ~200 V/cm remained constant throughout the exposure. As a result of this work the varying electric fields and their impact on event reconstruction and discrimination were successfully modeled.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chromatographic separation of radioactive noble gases from xenon

The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopes 85 Kr and 39 Ar that are not removed by the in situ gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search exmperiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400 kg of xenon was processed, reducing the average concentration of krypton from 130 ppb to 3.5 ppt as measured by a cold-trap assisted mass spectroscopy system. Finally, a 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

First Searches for Axions and Axionlike Particles with the LUX Experiment

The first searches for axions and axionlike particles with the Large Underground Xenon experiment are presented. Under the assumption of an axioelectric interaction in xenon, the coupling constant between axions and electrons g Ae is tested using data collected in 2013 with an exposure totaling 95 live days ×118 kg. A double-sided, profile likelihood ratio statistic test excludes g Ae larger than 3.5 × 10 –12 (90% C.L.) for solar axions. Assuming the Dine-Fischler-Srednicki-Zhitnitsky theoretical description, the upper limit in coupling corresponds to an upper limit on axion mass of 0.12 eV/c 2 , while for the Kim-Shifman-Vainshtein-Zhakharov description masses above 36.6 eV/c 2 are excluded. For galactic axionlike particles, values of g Ae larger than 4.2 × 10 –13 are excluded for particle masses in the range 1–16 keV/c 2 . As a result, these are the most stringent constraints to date for these interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure

We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg yr exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% C.L. upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of σ n = 1.6 × 10 –41 cm 2 (σ p = 5 × 10 –40 cm 2 ) at 35 GeV c –2 , almost a sixfold improvement over the previous LUX spin-dependent results. Finally, the spin-dependent WIMP-neutron limit is the most sensitive constraint to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signal yields, energy resolution, and recombination fluctuations in liquid xenon

This study presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additionally, there is an interpretation of existing measurements and descriptions of electron-ion recombination fluctuations in liquid xenon as limiting cases of a more general liquid xenon recombination fluctuation model. Measurements of the standard deviation of these fluctuations at monoenergetic electronic recoil peaks exhibit a linear dependence on the number of ions for energy deposits up to 661.7 keV, consistent with previous LUX measurements between 2 and 16 keV with 3 H. We highlight similarities in liquid xenon recombination for electronic and nuclear recoils with a comparison of recombination fluctuations measured with low-energy calibration data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from a search for dark matter in the complete LUX exposure

Here, we report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35 ×10 4 kg day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV c –2 , WIMP-nucleon spin-independent cross sections above 2.2 ×10 –46 cm 2 are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1 × 10 –46 cm 2 at 50 GeV c –2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Results of the LUX Dark Matter Experiment

LUX (Large Underground Xenon) is a dark matter direct detection experiment deployed at the 4850' level of the Sanford Underground Research Facility (SURF) in Lead, SD, operating a 370 kg dual-phase xenon TPC. Results of the first WIMP search run were presented in late 2013, for the analysis of 85.3 live-days with a fiducial volume of 118 kg, taken during the period of April to August 2013. The experiment exhibited a sensitivity to spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of 7.6×10 -46 cm 2 at a WIMP mass of 33 GeV/c 2 , thus becoming the world's leading WIMP search result, in conflict with several previous claimed hints of discovery.

79 ASTRONOMY AND ASTROPHYSICS↗

FPGA-based trigger system for the LUX dark matter experiment

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector are processed with an FPGA-based digital trigger system that analyzes the incoming data in real-time, with just a few microsecond latency. The system enables first pass selection of events of interest based on their pulse shape characteristics and 3D localization of the interactions. It has been shown to be >99% efficient in triggering on S2 signals induced by only few extracted liquid electrons. It is continuously and reliably operating since its full underground deployment in early 2013. This document is an overview of the systems capabilities, its inner workings, and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tritium calibration of the LUX dark matter experiment

Here, we present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 and 105 V/cm and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a reanalysis of the LUX run 3 weakly interacting massive particle search.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An estimation of photon scattering length in tetraphenyl-butadiene

Tetraphenyl-butadiene (TPB) is a wavelength shifting material that can absorb ultraviolet photons and emit blue photons. It is used in the detection of vacuum ultraviolet (VUV) photons, for which typical photo-sensors, such as most photomultiplier tubes (PMT) and silicon photomultipliers (SiPM), do not have any quantum efficiency. The secondary blue light is emitted isotropically, however, due to scattering within the material, its angular distribution upon exiting the material can not be easily predicted. In this work, we describe a procedure for estimating the scattering length of blue light in TPB, by measuring and modeling the angular distribution as a function of layer thickness. The experiment consists of shining 254nm light at various thicknesses of TPB deposited on fused silica, and measuring the intensity of blue light using SiPMs on either side of the sample. We simulate light propagation within the sample to estimate the light yield and compare that to the data, which allows us to estimate mean scattering length for photons in TPB to be in the range 2–3 µm, with some preference for a central value of 2.75 µm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from the LUX dark matter experiment

© 2014 Elsevier B.V. The LUX (Large Underground Xenon) experiment aims at the direct detection of dark matter particles via their collisions with xenon nuclei. The 370. kg two-phase liquid xenon time projection chamber measures simultaneously the scintillation and ionization from interactions in the target. The ratio of these two signals provides very good discrimination between potential nuclear recoil and electronic recoil signals to search for WIMP-nucleon scattering. The LUX detector operates at the Sanford Underground Research Facility (Lead, South Dakota, USA) since February 2013. First results were presented in late 2013 setting the world's most stringent limits on WIMP-nucleon scattering cross-sections over a wide range of WIMP masses. A 300 day run beginning in 2014 will further improve the sensitivity and new calibration techniques will reduce systematics for the WIMP signal search.

Horn, Markus↗