Publications and source records attributed to Trimmer, D. S..

Jet pump assisted arterial heat pipe

This paper discusses the concept of an arterial heat pipe with a capillary driven jet pump. The jet pump generates a suction which pumps vapor and noncondensible gas from the artery. The suction also forces liquid into the artery and maintains it in a primed condition. A theoretical model was developed which predicts the existence of two stable ranges. Up to a certain tilt the artery will prime by itself once a heat load is applied to the heat pipe. At higher tilts, the jet pump can maintain the artery in a primed condition but self-priming is not possible. A prototype heat pipe was tested which self-primed up to a tilt of 1.9 cm, with a heat load of 500 watts. The heat pipe continued to prime reliably when operated as a VCHP, i.e., after a large amount of noncondensible gas was introduced.

Bienert, W. B.↗

Development of a jet pump-assisted arterial heat pipe

The development of a jet pump assisted arterial heat pipe is described. The concept utilizes a built-in capillary driven jet pump to remove vapor and gas from the artery and to prime it. The continuous pumping action also prevents depriming during operation of the heat pipe. The concept is applicable to fixed conductance and gas loaded variable conductance heat pipes. A theoretical model for the jet pump assisted arterial heat pipe is presented. The model was used to design a prototype for laboratory demonstration. The 1.2 m long heat pipe was designed to transport 500 watts and to prime at an adverse elevation of up to 1.3 cm. The test results were in good agreement with the theoretical predictions. The heat pipe carried as much as 540 watts and was able to prime up to 1.9 cm. Introduction of a considerable amount of noncondensible gas had no adverse effect on the priming capability.

Bienert, W. B.↗

Design, development and testing of a cryogenic temperature heat pipe for the icicle system

An analytical model was formulated for a cryogenic heat pipe, and thermal and transport analyses were developed to predict the performance characteristics of various heat pipe designs. These analyses permitted optimization of various design parameters. A series of four breadboard heat pipes were fabricated and tested to provide inputs such as internal film coefficients, minimum capillary radii, and wick permeabilities which are required for the analyses. The results of instrumentation, charging, and testing of cryogenic heat pipes were applied to the prototype heat pipes. After a thorough design analysis of three potential heat pipe wicks (slab, artery, and axial groove), the first two were chosen for application to two prototype heat pipes. Detailed designs were made of the two heat pipes and the units were fabricated. Tests were conducted which verified the integrity and safety margin of the design to withstand the internal pressure at ambient temperature and fatigue of thermal cycling. During the acceptance testing in the vacuum chamber, no difficulty was experienced in priming the slab-wick heat pipe and it met the performance design requirements. The artery-wick heat pipe would not prime with nitrogen working fluid for any test conditions.

Trimmer, D. S.↗