Advanced Neutron Non-destructive Assay Methods for 233U Mass Quantification in Emerging Thorium Fuel Cycles
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Trellue, Holly Renee.
Explore the source record for details and available documents.
When designing a novel reactor, nuclear experiments are essential to validate the predictive capability of modeling/simulation tools and to justify the investment of a full-scale prototype. Being able to accurately predict temperature reactivity coefficients is of high importance to reactor designers as it impacts the safety and performance of the system. Deimos is a proposed graphite-moderated, beryllium-reflected, high assay low-enriched uranium (HALEU) tri-structural isotropic (TRISO) fueled experiment for NCERC. Deimos is a valuable experiment for validating the predictive performance of modeling and simulation tools since it comprises a relatively thermal energy spectrum with 84% thermal neutrons causing fission, 15% epithermal neutrons causing fission, and 1% fast neutrons causing fission. Additionally, by electrically heating the experiment, reactivity can be validated at various temperatures. Deimos will serve as a testbed for future advanced reactor concepts.
High hydrogen density moderators such as metal hydrides are an important research topic within the DOE NE Microreactor Program due to their ability to retain hydrogen to much higher temperatures than other hydrogenous media. This class of moderators, which includes yttrium dihydride (YH 2 ), thermalizes neutrons in the system such that the overall fuel mass or the required uranium enrichment in the system can be significantly reduced. Knowledge of material properties, both in the as-fabricated and irradiated state, are important to understanding moderator performance during steady-state and transient reactor operation.
This report summarizes the development of neutron imaging capabilities and experimental activities performed at the Los Alamos Neutron Science Center (LANSCE) with the main goal of measuring temperature-driven hydrogen diffusion within bulk-yttrium hydride (YH x ) materials. Yttrium hydride is the leading candidate to serve as a solid neutron moderator in microreactor cores, owing to its high density of hydrogen atoms as well as its superior thermal stability compared to all other metal hydrides. The experimental results and technique developments reported herein support the U.S. Department of Energy Office of Nuclear Energy’s (DOE-NE) Microreactor Program under Technology Maturation. In particular, it addresses the critical need to experimentally validate and verify hydrogen-diffusion models of metal hydrides used in high-temperature microreactor designs by means of high-spatial-resolution neutron imaging. These capabilities were designed to apply large temperature gradients across centimeter-sized YH x pellets to simulate conditions faced in the microreactor environment. In principle, neutron imaging, combined with in-situ sample heating, enables near real-time tracking of hydrogen diffusion in YH x on the sub-millimeter scale. In this report, an overview of neutron imaging methodology and technologies are given in the context of recent spatial measures of hydrogen concentrations in similar metal hydrides. Additionally, the commissioning and operation of a custom-built compact dual-zone furnace is given along with details on three in-situ heating measurements of YH x performed over the 2020 to 2022 LANSCE operation cycles. The aims of these experiments ranged from furnace commissioning, determining sample quality, i.e., hydrogen uniformity via neutron computed tomography, and studying the effects of applied temperature-gradients on YH x pellets. Analyses and results from these neutron imaging measurements are given along with outlooks and guidelines for optimal future hydrogen diffusion measurements. Our conclusions are as follows. Image analyses indicate that centimeter-sized yttrium hydride cylindrical pellets exhibit uniform, whole-body hydrogen desorption and absorption without clear temperature dependence as reflected in the image attenuation at the opposing ends of each sample. This suggests that despite the large magnitude in temperature gradients applied by the furnace heating elements, the sample equilibrates to an unknown intermediate temperature. The origin of this result is likely the combination of short sample length (∼1cm) and use of a TZM can for containment where the latter created a thermal short across the sample. Nevertheless, the results from the most recent measurements indicate that neither significant concentration gradients of hydrogen were formed in centimeter-sized samples through the entire temperature range (25 °C to 950 °C) nor any formed due to temperature gradients on the order of 50 °C/cm up to 700 °C/cm. Furthermore, images from the FY2021 and FY2022 measurements indicate that samples of YH x , fabricated from either the direct hydride or powder metallurgy methods, are highly uniform in their hydrogen concentration to within the measurements’ spatial resolutions. The following questions arise from these latest results: 1) What is the intermediate temperature of the pellets in the TZM cans? 2) How quickly does the temperature equilibrate within the sample? and, 3) Do the observed changes in image attenuation follow known pressure-composition-temperature relations of yttrium hydride?