Engineering Papers⌕ Search

Engineering topics

Torres, J

Publications and source records attributed to Torres, J.

SU-F-P-40: Analysis of Pelvic Lymph Node Margin Using Prostate Fiducial Markers, for SBRT Treatments

Purpose: The use of fiducials markers in prostate treatment allows a precise localization of this volume. Typical prostate SBRT margins with fiducials markers are 5mm in all directions, except toward the rectum, where 3mm is used. For some patients nearby pelvic lymph nodes with 5mm margin need to be irradiate assuming that its localization is linked to the prostate fiducial markers instead of bony anatomy. The purpose of this work was to analyze the geometric impact of locate the lymph node regions through the patient positioning by prostate fiducial markers. Methods: 10 patients with prostate SBRT with lymph nodes irradiation were selected. Each patient had 5 implanted titanium fiducial markers. A Novalis TX (BrainLAB-Varian) with ExacTrac and aSi1000 portal image was used. Treatment plan uses 11 beams with a dose prescription (D95%) of 40Gy to the prostate and 25Gy to the lymph node in 5 fractions. Daily positioning was carried out by ExacTrac system based on the implanted fiducials as the reference treatment position; further position verification was performed using the ExacTrac and two portal images (gantry angle 0 and 90) based on bony structures. Comparison between reference position with bony based ExacTrac and portal image localization, was done for each treatment fraction Results: A total of 50 positioning analysis were done. The average discrepancy between reference treatment position and ExacTrac based on bony anatomy (pubic area) was 4.2mm [0.3; 11.2]. The discrepancy was <5mm in 61% of the cases and <9mm in 92%. Using portal images the average discrepancy was 3.7mm [0.0; 11.1]. The discrepancy was <5mm in 69% of the cases and <9mm in 96%. Conclusion: Localizing lymph node by prostate fiducial markers may produce large discrepancy as large as 11mm compared to bony based localization. Dosimetric impact of this discrepancy should be studied.

60 APPLIED LIFE SCIENCES↗

SU-F-P-55: Testicular Scatter Dose Determination During Prostate SBRT with and Without Pelvic Lymph Nodes

Purpose: The elective irradiation of pelvis lymph node for prostate cancer is still controversial. Including pelvic lymph node as part of the planning target volume could increase the testicular scatter dose, which could have a clinical impact. The objective of this work was to measure testicular scatter dose for prostate SBRT treatment with and without pelvic lymph nodes using TLD dosimetry. Methods: A 6MV beam (1000UM/min) produce by a Novalis TX (BrainLAB-VARIAN) equipped HDMLC was used. Treatment plan were done using iPlan v4.5.3 (BrainLAB) treatment planning system with sliding windows IMRT technique. Prostate SBRT plan (PLAN-1) uses 9 beams with a dose prescription (D95%) of 4000cGy in 5 fractions. Prostate with lymph nodes SBRT plan (PLAN-2) uses 11 beams with a dose prescription (D95%) of 4000cGy to the prostate and 2500cGy to the lymph node in 5 fractions. An anthropomorphic pelvic phantom with a testicular volume was used. Phantom was positioned using ExacTrac IGRT system. Phosphor TLDs LiF:Mg, Ti (TLD700 Harshaw) were positioned in the anterior, posterior and inferior portion of the testicle. Two set of TLD measurements was done for each treatment plan. TLD in vivo dosimetry was done in one patient for each treatment plan. Results: The average phantom scatter doses per fraction for the PLAN-1 were 10.9±1cGy (anterior), 7.8±1cGy (inferior) and 10.7±1cGy (posterior) which represent an average total dose of 48±1cGy (1.2% of prostate dose prescription). The doses for PLAN-2 plan were 17.7±1cGy (anterior), 11±1cGy (inferior) and 13.3±1cGy (posterior) which represent an average total dose of 70.1±1cGy (1.8% of prostate dose prescription). The average dose for in vivo patient dosimetry was 60±1cGy for PLAN-1 and 85±1cGy for PLAN-2. Conclusion: Phantom and in vivo dosimetry shows that the pelvic lymph node irradiation with SBRT slightly increases the testicular scatter dose, which could have a clinical impact.

60 APPLIED LIFE SCIENCES↗

Multiple diagnostics in a high-pressure hydrogen microwave plasma torch

We present an experimental study of a hydrogen plasma produced by a microwave axial injection torch, launching the plasma in a helium-filled chamber. Three different diagnostic methods have been used to obtain the electron density and temperature as follows: The Stark intersection method of Balmer spectral lines (already tested in argon and helium plasmas); the modified Boltzmann-plot showing that the plasma is far from the local thermodynamic equilibrium but ruled by the excitation-saturation balance; and a study by the disturbed bilateral relations theory. All of these diagnostic techniques show a good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrodynamic modeling of optically excited terahertz plasma oscillations in nanometric field effect transistors

We present a hydrodynamic model to simulate the excitation by optical beating of plasma waves in nanometric field effect transistors. The biasing conditions are whatever possible from Ohmic to saturation conditions. The model provides a direct calculation of the time-dependent voltage response of the transistors, which can be separated into an average and a harmonic component. These quantities are interpreted by generalizing the concepts of plasma transit time and wave increment to the case of nonuniform channels. The possibilities to tune and to optimize the plasma resonance at room temperature by varying the drain voltage are demonstrated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Experimental Characterization Of The Asymmetry And The Dip Form Of The H{sub {beta}}-Line Profiles In Microwave-Produced Plasmas At Atmospheric Pressure

An experimental study on the asymmetry of the Balmer H{sub {beta}} profile in plasmas produced by microwaves at atmospheric pressure is presented. The asymmetry of the whole profile is studied with the help of one function that quantified this characteristic. The asymmetry and shape of the central valley is also studied with the definition of several parameters. The study shows the presence of the Stark asymmetry in plasmas with electron density of the order of 10{sup 21}m{sup -3}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

One-Dimensional Neutron Imager for the Sandia Z Facility

A multi-institution collaboration is developing a neutron imaging system for the Sandia Z Facility. The initial system design is for slit-aperture imaging system capable of obtaining a 1-D image of a 2.45-MeV source producing 5 x 10{sup 12} neutrons with a resolution of 320 {micro}m along the axial dimension of the plasma, but the design being developed can be modified for 2-D imaging and imaging of DT neutrons with other resolutions. This system will allow us to understand the spatial production of neutrons in the plasmas produced at the Z Facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Renewable Systems Interconnection: Executive Summary

The U.S. Department of Energy launched the Renewable Systems Interconnection (RSI) study in 2007 to address the challenges to high penetrations of distributed renewable energy technologies. The RSI study consists of 14 additional reports.

14 SOLAR ENERGY↗