Engineering Papers⌕ Search

Engineering topics

Torreblanca, H.

Publications and source records attributed to Torreblanca, H..

The high-power helicon program at DIII-D: gearing up for first experiments

Helicon current drive, also called fast wave current drive in the lower hybrid range of frequencies, has long been regarded as a promising current drive tool for reactor grade plasmas. A newly installed MW-level system at DIII-D will be the first test of this technology in reactor-relevant plasmas, in the sense that full single-pass absorption is expected. A 30-module traveling wave antenna has been installed and optimized in-vessel in early 2020. The linear electromagnetic characteristics of the unloaded module array have been extensively tested both on the bench and in the vessel at instrumentation power levels. Excellent performance has been achieved, ~2% reflected power and ~1.5% dissipated power per module in air, in a 10 MHz band around 476 MHz. Stripline feeds on both ends of the antenna allow either co or counter current drive. The installation of a 1.2 MW klystron and associated high-power electronics was completed in Fall 2020. Commissioning of the antenna is ongoing. An important goal of this experiment is to validate the helicon current drive physics basis using an extensive set of new and upgraded diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance demonstration of vacuum microwave components critical for the operation of the ITER low-field side reflectometer

Final design studies in preparation for manufacturing have been performed for functional components of the vacuum portion of the ITER Low-Field Side Reflectometer (LFSR). These components consist of an antenna array, electron cyclotron heating (ECH) protection mirrors, phase calibration mirrors, and vacuum windows. Evaluation of these components was conducted at the LFSR test facility and DIII-D. The antenna array consists of six corrugated-waveguide antennas for simultaneous profile, fluctuation, and Doppler measurements. A diffraction grating, incorporated into the plasma-facing miter bend, provides protection of sensitive components from stray ECH at 170 GHz. For in situ phase calibration of the LFSR profile reflectometer, an embossed mirror is incorporated into the adjacent miter bend. Measurements of the radiated beam profile indicate that these components have a small, acceptable effect on mode conversion and beam quality. Baseline transmission characteristics of the dual-disk vacuum window are obtained and are used to guide ongoing developments. Preliminary simulations indicate that a surface-relief structure on the window surfaces can greatly improve transmission. The workability of real-time phase measurements was demonstrated on the DIII-D profile reflectometer. The new automated real-time analysis agrees well with the standard post-processing routine.

47 OTHER INSTRUMENTATION↗

Toroidal Field Reversing Switch

A motor-driven, high-current switch is being designed by Stäubli Electrical Connectors in collaboration with Princeton Plasma Physics Laboratory to reverse the DIII-D Toroidal field coil current. The existing field reversing procedure requires approximately 4 h of labor performed between run days to reconfigure the bus work, thus requiring a separate run day to complete experimental scans with both field directions. This typically results in different wall conditions which complicate the results or make them invalid. The proposed switch will complete the reversal process in approximately 4-5 min, between shots, so that wall conditions are not a factor, and easily fits within the 10-12 min DIII-D shot cycle. The switch is a compact design fitting into a 157.5 × 41 cm envelope. The switch uses two copper pins that slide between Stäubli MULTILAM contacts. The switch is rated for total current of 180-kA dc for 10 s with a 12-min repetition rate; the maximum operating coil current is 124-kA dc. The switch diagnostics include: voltage drop, current monitor, thermal monitors, position sensors, and motor torque. Here, the switch is rated for 300 cycles per year, and 3000 cycles overall before contact replacement, with contact inspection yearly. The design details and operation of the switch are covered in this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗