Engineering Papers⌕ Search

Engineering topics

Tittmann, B. R.

Publications and source records attributed to Tittmann, B. R..

At least 19 records

Review of Progress in Atomic Force Microscopy

The study of biological samples is one of the most attractive and innovative fields of application of atomic force microscopy AFM. Recent breakthroughs in software and hardware have revolutionized this field and this paper reports on recent trends and describes examples of applications on biological samples. Originally developed for high-resolution imaging purposes, the AFM also has unique capabilities as a nano-indentor to probe the dynamic visco-elastic material properties of living cells in culture. In particular, AFM elastography combines imaging and indentation modalities to map the spatial distribution of cell mechanical properties, which in turn reflect the structure and function of the underlying structure. This paper describes the progress and development of atomic force microscopy as applied to animal and plant cell structures.

47 OTHER INSTRUMENTATION↗

Sol-gel deposited transducers characteristics: A weight percent study - 15718

Monitoring functional machinery components that operate at elevated temperatures is costly and time consuming. This work explores leave in place composite transducers for high temperature monitoring of machinery components. A theoretical model was developed utilizing software provided by NASA. This model was then compared to the experimental results. The objective is to determine the characteristics of a set of spray-on composite transducers to identify the ideal transducer for any situation where a certain specification is made: - Operating temperature; - Signal amplitude/Signal to noise ratio; - Specific material property. The transducer is fabricated through a sol-gel deposition process that utilizes spraying the transducer onto the substrate. A sol-gel solution containing bismuth titanate is mixed with a combination of bismuth titanate and lead zirconate titanate(PZT) powders to create a composite transducer. Typical sintering methods have proved to be destructive and difficult to handle for the sol-gel deposition method; however, induction sintering has proved effective. -d{sub 33} decreases with increasing weight percent of bismuth titanate -the maximum usable temperature increases with increasing weight percent bismuth titanate -signal amplitude is also higher with increasing weight percent of bismuth titanate The ideal composition for the best signal amplitude and the highest operating temperature has been shown to be pure bismuth titanate; however, if the properties of the transducer are of utmost importance including conductivity and density then PZT should be added to increase these properties. The theoretical NASA Micromechanical Analysis Code by Generalized Method of Cell model has been validated through the experimental results of these experiments. Now that the composition of the transducer has been optimized to a specific application the future work is comprised of: - Utilizing the information to evaluate wall thickness - Integrating the optimized transducer with a wireless system for remote monitoring of mechanical component - Establishing a field deposition method for the spray-on transducer.

36 MATERIALS SCIENCE↗

Imaging and quantitative data acquisition of biological cell walls with Atomic Force Microscopy and Scanning Acoustic Microscopy

This chapter demonstrates the feasibility of Atomic Force Microscopy (AFM) and High Frequency Scanning Acoustic Microscopy (HF-SAM) as tools to characterize biological tissues. Both the AFM and the SAM have shown to provide imaging (with different resolution) and quantitative elasticity measuring abilities. Plant cell walls with minimal disturbance and under conditions of their native state have been examined with these two kinds of microscopy. After descriptions of both the SAM and AFM, their special features and the typical sample preparation is discussed. The sample preparation is focused here on epidermal peels of onion scales and celery epidermis cells which were sectioned for the AFM to visualize the inner surface (closest to the plasma membrane) of the outer epidermal wall. The nm-wide cellulose microfibrils orientation and multilayer structure were clearly observed. The microfibril orientation and alignment tend to be more organized in older scales compared with younger scales. The onion epidermis cell wall was also used as a test analog to study cell wall elasticity by the AFM nanoindentation and the SAM V(z) feature. The novelty in this work was to demonstrate the capability of these two techniques to analyze isolated, single layered plant cell walls in their natural state. AFM nanoindentation was also used to probe the effects of Ethylenediaminetetraacetic acid (EDTA), and calcium ion treatment to modify pectin networks in cell walls. The results suggest a significant modulus increase in the calcium ion treatment and a slight decrease in EDTA treatment. To complement the AFM measurements, the HF-SAM was used to obtain the V(z) signatures of the onion epidermis. These measurements were focused on documenting the effect of pectinase enzyme treatment. The results indicate a significant change in the V(z) signature curves with time into the enzyme treatment. Thus AFM and HF-SAM open the door to a systematic nondestructive structure and mechanical property study of complex biological cell walls. A unique feature of this approach is that both microscopes allow the biological samples to be examined in their natural fluid (water) environment.

nanoindentation↗

High temperature ultrasonic transducers for the generation of guided waves for non-destructive evaluation of pipes

Applications for non-destructive evaluation and structural health monitoring of steam generators require ultrasonic transducers capable of withstanding the high temperatures of the pipes and heat exchangers. These applications require a strong coupling of the transducer to the heat exchanger’s complex geometry at the elevated temperatures. Our objective is to use spray-on piezo-electrics for depositing comb transducers onto the curved surfaces. This paper shows results for composite transducers such as lead zirconate titanate/ bismuth titanate and bismuth titanate/ lithium niobate. The comb transducers were prepared by precision laser ablation. The feasibility of producing second harmonic waves in rods with these spay-on comb transducers was demonstrated and paves the way toward measuring material degradation early-on before crack initiation occurs.

42 ENGINEERING↗

Selecting a radiation tolerant piezoelectric material for nuclear reactor applications

Bringing systems for online monitoring of nuclear reactors to fruition has been delayed by the lack of suitable ultrasonic sensors. Recent work has demonstrated the capability of an AlN sensor to perform ultrasonic evaluation in an actual nuclear reactor. Although the AlN demonstrated sustainability, no loss in signal amplitude and d{sub 33} up to a fast and thermal neutron fluence of 1.85 Multiplication-Sign 1018 n/cm{sup 2} and 5.8 Multiplication-Sign 1018 n/cm{sup 2} respectively, no formal process to selecting a suitable sensor material was made. It would be ideal to use first principles approaches to somehow reduce each candidate piezoelectric material to a simple ranking showing directly which materials one should expect to be most radiation tolerant. However, the complexity of the problem makes such a ranking impractical and one must appeal to experimental observations. This should not be of any surprise to one whom is familiar with material science as most material properties are obtained in this manner. Therefore, this work adopts a similar approach, the mechanisms affecting radiation tolerance are discussed and a good engineering sense is used for material qualification of the candidate piezoelectric materials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultrasonic characterization of microstructure in powder metal alloy

The ultrasonic wave propagation characteristics were measured for IN-100, a powder metallurgy alloy used for aircraft engine components. This material was as a model system for testing the feasibility of characterizing the microstructure of a variety of inhomogeneous media including powder metals, ceramics, castings and components. The data were obtained for a frequency range from about 2 to 20 MHz and were statistically averaged over numerous volume elements of the samples. Micrographical examination provided size and number distributions for grain and pore structure. The results showed that the predominant source for the ultrasonic attenuation and backscatter was a dense (approx. 100/cubic mm) distribution of small micropores (approx. 10 micron radius). Two samples with different micropore densities were studied in detail to test the feasibility of calculating from observed microstructural parameters the frequency dependence of the microstructural backscatter in the regime for which the wavelength is much larger than the size of the individual scattering centers. Excellent agreement was found between predicted and observed values so as to demonstrate the feasibility of solving the forward problem. The results suggest a way towards the nondestructive detection and characterization of anomalous distributions of micropores when conventional ultrasonic imaging is difficult. The findings are potentially significant toward the application of the early detection of porosity during the materials fabrication process and after manufacturing of potential sites for stress induced void coalescence leading to crack initiation and subsequent failure.

Tittmann, B. R.↗

NDE of simulated Space Shuttle tile disbonds

A technique which involves the use of ultrasonic Lamb waves for assaying the structural integrity of adhesive bonds between layered materials on thin metal plates, particularly with regard to the Shuttle TPS, is presented. The Lamb waves are generated by a pulse impact, resulting in surface waves propagating radially at 2.4 mm/microsec. Trials were performed with the sound waves applied to samples, of aluminum similar to the Orbiter external skin, which were coated with Teflon and a RTV silicone screed. The goal was to detect localized debonded areas or potentially debonded areas, which, during reentry, could result in blistering of the aluminum skin. The ultrasonic probes are described, noting the usage of broadband ultrasonic harmonics and a minicomputer processor. The testing system was found to accurately identify weakened bonds by the ratio of high and low frequency component areas of the received signal of the Lamb waves sent across the surface.

Ahlberg, L.↗

High-temperature high-pressure magnetic pickup

Magnetic-pickup transducers operate at temperature as high as 1,100 C and pressures in excess of 2.5 kilobars. Transducers obtain simulated seismic data in laboratory experiments at high temperatures and pressure. They also have potential applications in industrial instrumentation for measurements under similarly difficult conditions. Transducers use high-temperature cement to bond parts together and high-temperature-insulated copper or aluminum wire for windings.

Ahlberg, L. A.↗

Internal friction and modulus in rocks at depth

Experimental results relevant to the seismic wave attenuation observed for the lunar crust are presented along with some results bearing on the mechanism by which the presence of volatiles increases the attenuation.

Tittmann, B. R.↗

Brief note for consideration of active seismic exploration on Mars

Considerable controversy has arisen regarding the existence of water and water ice below the surface of Mars. Results of laboratory internal friction measurements on strongly outgassed rocks, recently made as part of an effort to interpret the high seismic Q values observed in the lunar crust, show that moisture absorbed in pores and cracks causes the low Q values. Unfortunately, the Viking seismology investigation found a surprisingly inactive planet. This note makes the case for active seismic exploration in order to ascertain the existence of liquid water in the crust from Q determinations.

Tittmann, B. R.↗

Seismic Q and velocity at depth

Measurements of the p-wave and s-wave internal friction quality factors (Q) and velocities of samples of a moderately outgassed terrestrial analog of lunar basalt exposed simultaneously to temperatures and hydrostatic confining pressures in accordance with the best available estimates of the lunar selenotherm are presented. Q values and velocities are found to increase with simulated depth, and an extrapolation of the Q value to a thoroughly outgassed states provides a Q value in reasonable agreement with those derived from lunar seismic data, suggesting a very dry lunar crust. Results also imply that similar seismic determinations for Mars would be able to distinguish between a dry crust and a crust containing water trapped beneath a layer of ice. Results of thermal cracking tests which demonstrate that high degrees of cracking associated with thermal cycling, as during the lunar day, are not inconsistent with high Q in a dry environment are presented, and it is shown that volatiles with diple moments comparable to H2O can greatly affect Q. Possible attenuation mechanisms are then considered, and velocity measurements on a synthetic anorthosite are presented.

Tittmann, B. R.↗

Internal friction Q factor measurements in lunar rocks

In order to better interpret recently reported values for the variation of seismic Q as a function of depth below the lunar surface, we have developed apparatus and made laboratory measurements of Q as a function of hydrostatic pressure, temperature and frequency. Our measurements of the Q associated with shear deformations have demonstrated that the large difference in Q between well outgassed and volatile rich rocks persists to pressures corresponding to a depth of at least 50 km. Here we report new measurements of Q as a function of temperature, on the development of techniques to measure the Q associated with extensional deformations under hydrostatic pressure, on the derivation of theoretical relations between our laboratory Q values and the attenuation coefficient of seismic waves, and on the development of a model for mechanism of adsorption.

Tittmann, B. R.↗

Laboratory measurements of p-wave seismic Q on lunar and analog rocks

The longitudinal-wave, internal friction quality factor (Qp) of out-gassed rock subjected to hydrostatic confining pressure was measured by a technique of aerodynamically shaping the sample ends to remove most of the air drag. Q values of about 1000 and 100 were obtained at 100 MPa and in laboratory air, respectively. The temperature dependence of Q in lunar rock 70215.85 and an analog of lunar basalt was investigated over the range -100 to 450 deg C. A systematic increase in Q was observed at 50 Hz, 5 kHz and 50 kHz. When the temperature was lowered to -100 deg C moderate decreases in Q were observed from 100 to 250 deg C, and high Q values were obtained at 450 deg C. The temperature and pressure dependences of Q suggest that high lunar seismic Q values imply a very dry crust to depths of at least 50 km. These results further indicate that elastic waves are damped in volatile-rich rock by an absorption mechanism which involves changes in the bonding, structure and coverage of the molecular, physisorbed and chemisorbed H2O at crack and grain boundaries.

Tittmann, B. R.↗

Internal friction Q factor measurements in lunar rocks

Investigations to aid in the interpretation of seismic data obtained below the lunar surface are reported. Fine grained basalt with about 1.0% open core porosity was encapsulated under hard vacuum and measured. A Q value just under 2,000 at 0.5 kbar was achieved for a terrestrial analog of lunar basalt. In contrast to the modulus which increases by as much as 10%, the quality factor Q shows little or no change with pressure (a well outgassed sample maintains a high Q, whereas one exposed to laboratory atmosphere maintains a low Q). This result suggests that the absence of volatiles plays an important role in determining the q factor even at a depth of 10 km below the lunar surface.

Tittmann, B. R.↗

Internal friction quality-factor Q under confining pressure

It has been found in previous studies that small amounts of adsorbed volatiles can have a profound effect on the internal friction quality-factor Q of rocks and other porous media. Pandit and Tozer (1970) have suggested that the laboratory-measured Q of volatile-free rocks should be similar to the in situ seismic Q values of near-surface lunar rocks which according to Latham et al. (1970) are in the range of 3000-5000. Observations of dramatic increases in Q with outgassing up to values approaching 2000 in the seismic frequency range confirm this supposition. Measurements under confining pressures with the sample encapsulated under hard vacuum are reported to aid in the interpretation of seismic data obtained below the lunar surface. It has been possible to achieve in the experiments Q values just under 2000 at about 1 kbar for a terrestrial analog of lunar basalt. It was found that a well-outgassed sample maintains a high Q whereas one exposed to moisture maintains a low Q as the confining pressure is raised to 2.5 kbar. This result suggests that volatiles can indeed affect Q when cracks are partially closed and the high lunar seismic Q values reported are concomitant with very dry rock down to depths of at least 50 km.

Tittmann, B. R.↗

Apparatus for measuring internal friction Q factors in brittle materials

A flexural analog of the torsion pendulum for measuring the Young's modulus and the internal friction Q factor of brittle materials has been developed for Q greater than 10 to the 3rd measurements at a zero static stress and at 10 to the -7th strains of brittle materials in the Hz frequency range. The present design was motivated by the desire to measure Q in fragile lunar return samples at zero static stress to shed light on the anomalously low attenuation of seismic waves on the moon. The use of the apparatus is demonstrated with data on fused silica and on a terrestrial analog of lunar basalt.

Tittmann, B. R.↗

Reduction of losses in low-frequency /2 MHz/ surface-wave delay line by outgassing

Surface waves are attenuated by a fluid or gas surrounding the surface of propagation, an effect caused by frictional losses determined by the fluid or gas viscosity and by the emission of compression waves into the environment. The paper reports a large reversible reduction in attenuation of surface waves at frequencies as low as 2 MHz by outgassing treatments of some materials, suggesting that at such frequencies vacuum encapsulation is a desirable procedure. Outgassing experiments were performed on a delay line constructed from high-density p.z.t.-8 (lead-zirconate-titanate). The delay line configuration was a slab waxed onto a metal base with coaxial connectors mounted near and connected by gold-wire leads to the interdigital finger sets. Output signal enhancements by as much as 8 dB were achieved after overnight evacuation at 10 to the -2 torr at room temperature.

Tittmann, B. R.↗

Reduction of acoustic losses by outgassing

Heat treatment procedure at low pressure increases internal-friction quality factor of treated samples. Method can reduce propagation losses in porous ferroelectric ceramics by as much as a factor of 100.

Cirlin, E. H.↗