Engineering PapersSearch

Engineering topics

Thornton, W. E.

Publications and source records attributed to Thornton, W. E..

The Kinematics of Treadmill Locomotion in Space

Locomotion on a treadmill in 0 G will probably remain a centerpiece of NASA's exercise countermeasures programme. This form of physical activity has the potential to cause large bone and muscle forces as well as loading during a period of continuous treadmill exercise. A critical concern is the provision of a treadmill which can approximate 1 G performance in space. At this point, no adequate objective measurements of in-flight treadmill kinetics or of the human response to this activity have been made. Interpretation of the results obtained in the present study is limited by the following: (1) bungee tensions were not measured; (2) ground reaction forces were not measured in parallel with the kinematic measurements; and (3) the instrumentation used to film the astronauts could itself have been affected by microgravity. Despite these shortcomings, what is apparent is that exercise during NASA missions STS 7 and STS 8 resulted in leg motions that were similar to those found during 1 G locomotion on an inclined passive treadmill and on an active treadmill at an even steeper grade. In addition, it was apparent that the majority of the loads were transmitted through the forefoot, and one can surmise that this style of running would result in physiologically significant tensions in the calf musculature and resultant ankle compressive loading. Further speculation regarding limb loading is complicated by the fact that varying amounts of force are transmitted through (1) the treadmill handle and (2) bungee cords that act as a tether. New generations of treadmills are being manufactured that could provide I important information for planners of long-duration space missions. If these types of treadmill are flown on future missions, it will be possible to control bungee tensions more precisely, control for grade and speed, and, most importantly, provide data on the rates and magnitudes of limb loading. These data could then be incorporated into biomechanical models of the lower limb to more fully understand mechanisms of load transmission from distal to proximal structures and to optimize in-flight exercise protocols in such a way that muscle and bone loss could be reduced.

Thornton, W. E.

Improved method and apparatus for waste collection and storage

A method and apparatus for the collection of fecal matter are designed to operate efficiently in a zero gravity environment. The system comprises a waste collection area within a body having a seat opening. Low pressure within the waste collection area directs fecal matter away from the user's buttocks and prevents the escape of undesirable gases. The user actuates a piston covered with an absorbent pad that sweeps through the waste collection area to collect fecal matter, scrub the waste collection area, press the matter against an end of the waste collection area and retracts, leaving the used pad. Multiple pads are provided on the piston to accommodate multiple uses of the system. Also a valve allows air to be drawn through the body, which valve will not be plugged with fecal matter. A sheet feeder feeds fresh sheets of absorbent pad to a face of the piston with each actuation.

Thornton, W. E.

Method and apparatus for simulating gravitational forces on a living organism

A method and apparatus for simulating gravitational forces on a living organism wherein a series of negative pressures are externally applied to successive length-wise sections of a lower limb of the organism. The pressures decreasing progressively with distance of said limb sections from the heart of the organism. A casing defines a chamber adapted to contain the limb of the organism and is rigidified to resist collapse upon the application of negative pressures to the interior of the chamber. Seals extend inwardly from the casing for effective engagement with the limb of the organism and, in cooperation with the limb, subdivide the chamber into a plurality of compartments each in negative pressure communicating relation with the limb.

Thornton, W. E.

Kinesimetric method and apparatus

Apparatus and method for the determination of functional capability of bodies are disclosed. Reach as well as velocity, acceleration and force generation at various positions may be determined for a body by a three dimensional kinesimeter equipped with an ergometer. A general data package indicative of performance potential of a subject body or collection of bodies is provided for interfacing with data characteristics of various environments.

Thornton, W. E.

Anthropometric sourcebook

Three-volume "Anthropometric Source Book' contains large body of anthropometric data, design information, and references. Subjects covered include variability in body size, mass distribution properties of human body, arm and leg reach, joint motion and numerous other materials.

Bond, R. L.

Physiological mass measurements in Skylab

A spring-mass oscillator constrained to linear motion was used to measure astronaut weight during Skylab mission. Plots of spacecrew body weights, preflight and postflight, and inflight equivalent weight measurements indicate high in-flight metabolic costs with weight losses under weightlessness conditions.

Thornton, W. E.

Muscular deconditioning and its prevention in space flight

Exercise and exercise devices on Skylab missions prevented muscle loss in spacecrews. It is concluded that muscle in space is no different from muscle on earth; if it is properly nourished and exercised at reasonable load levels, it maintains its function under weightlessness conditions.

Thornton, W. E.

Anthropometric changes and fluid shifts

In an effort to obtain the most comprehensive and coherent picture of changes under weightlessness, a set of measurements on Skylab 2 was initiated and at every opportunity, additional studies were added. All pertinent information from ancillary sources were gleaned and collated. On Skylab 2, the initial anthropometric studies were scheduled in conjunction with muscle study. A single set of facial photographs was made in-flight. Additional measurements were made on Skylab 3, with photographs and truncal and limb girth measurements in-flight. Prior to Skylab 4, it was felt there was considerable evidence for large and rapid fluid shifts, so a series of in-flight volume and center of mass measurements and infrared photographs were scheduled to be conducted in the Skylab 4 mission. A number of changes were properly documented for the first time, most important of which were the fluid shifts. The following description of Skylab anthropometrics address work done on Skylab 4 primarily.

Thornton, W. E.

Hemodynamic studies of the legs under weightlessness

Following exposure to weightlessness, alterations in the return of blood from the legs play a crucial role in orthostatic tolerance and may be an important factor in work tolerance. To investigate some of the hemodynamic mechansism involved, an experiment was performed on the Skylab 3 and Skylab 4 missions to study arterial blood flow, venous compliance, and muscle pumping of blood. Skylab 4 results indicated that the most likely cause of increased blood flow was an increase in cardiac output secondary to increased central venous pressure caused by blood redistribution. Changes in venous compliance are thought to be primarily changes in somatic musculature which is postulated to primarily determine venous compliance of the legs. This was also thought to be demonstrated by the changes in muscle pumping. It is thought that these compliance changes, when taken with the decreased blood volume; provide a basis for the changes seen in orthostatic tolerance, work capacity and lower body negative pressure response.

Thornton, W. E.

Anthropometric changes and fluid shifts

Several observations of body size, shape, posture, and configuration were made to document changes resulting from direct effects of weightlessness during the Skylab 4 mission. After the crewmen were placed in orbit, a number of anatomical and anthropometric changes occurred including a straightening of the thoracolumbar spine, a general decrease in truncal girth, and an increase in height. By the time of the earliest in-flight measurement on mission day 3, all crewmen had lost more than two liters of extravascular fluid from the calf and thigh. The puffy facies, the bird legs effect, the engorgement of upper body veins, and the reduced volume of lower body veins were all documented with photographs. Center-of-mass measurements confirmed a fluid shift cephalad. This shift remained throughout the mission until recovery, when a sharp reversal occurred; a major portion of the reversal was completed in a few hours. The anatomical changes are of considerable scientific interest and of import to the human factors design engineer, but the shifts of blood and extravascular fluid are of more consequence. It is hypothesized that the driving force for the fluid shift is the intrinsic and unopposed lower limb elasticity that forces venous blood and then other fluid cephalad.

Thornton, W. E.

Specimen mass measurement

The Skylab specimen mass measurement device was operated throughout the altitude test in close simulation of the 56-day Skylab mission. It performed operational specimen measurements well until it was passed out of the chamber for replacement of the specimen hold-down and was autoclaved prior to return. Fecal measurements were typically made with less than one percent error.

Thornton, W. E.

Crew report

A 56-day chamber simulation of Skylab was successfully completed. The atmosphere (5 psi, 70 percent oxygen, 30 percent nitrogen, 5 mm carbon dioxide) and medical features including a 21-day pre- and 18-day post-test medical protocols were closely simulated. No apparent crew health problems were induced by the atmosphere, semiclosed environment, or other test features; and no appreciable crew degradation appeared over this period. The chamber and associated systems performed without major problems.

Bobko, K. J.