Engineering Papers⌕ Search

Engineering topics

Thompson, R. E.

Publications and source records attributed to Thompson, R. E..

On the Quality of the Nimbus 7 LIMS Version 6 Water Vapor Profiles and Distributions

This report describes the quality of the Nimbus 7 Limb Infrared Monitor of the Stratosphere (LIMS) water vapor (H2O) profiles of 1978/79 that were processed with a Version 6 (V6) algorithm and archived in 2002. The V6 profiles incorporate a better knowledge of the instrument attitude for the LIMS measurements along its orbits, leading to improvements for its temperature profiles and for the registration of its water vapor radiances with pressure. As a result, the LIMS V6 zonal-mean distributions of H2O exhibit better hemispheric symmetry than was the case from the original Version 5 (V5) dataset that was archived in 1982. Estimates of the precision and accuracy of the V6 H2O profiles are developed and provided. Individual profiles have a precision of order 5% and an estimated accuracy of about 19% at 3 hPa, 14% at 10 hPa, and 26% at 50 hPa. Profile segments within about 2 km of the tropopause are often affected by emissions from clouds that appear in the finite field-of-view of the detector for the LIMS H2O channel. Zonally-averaged distributions of the LIMS V6 H2O are compared with those from the more recent Microwave Limb Sounder (MLS) satellite experiment for November, February, and May of 2004/2005. The patterns and values of their respective distributions are similar in many respects. Effects of a strengthened Brewer-Dobson circulation are indicated in the MLS distributions of the recent decade versus those of LIMS from 1978/79. A tropical tape recorder signal is present in the 7-month time series of LIMS V6 H2O with lowest values in February 1979, and the estimated, annually-averaged "entry-level" H2O is 3.5 to 3.8 ppmv. It is judged that this historic LIMS water vapor dataset is of good quality for studies of the near global-scale chemistry and transport for pressure levels from 3 hPa to about 70 to 100 hPa.

Remsberg, E. E.↗

Assessment of the Quality of the Version 1.07 Temperature-Versus-Pressure Profiles of the Middle Atmosphere from TIMED/SABER

The quality of the retrieved temperature-versus-pressure (or T(p)) profiles is described for the middle atmosphere for the publicly available Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) Version 1.07 (V1.07) data set. The primary sources of systematic error for the SABER results below about 70 km are (1) errors in the measured radiances, (2) biases in the forward model, and (3) uncertainties in the corrections for ozone and in the determination of the reference pressure for the retrieved profiles. Comparisons with other correlative data sets indicate that SABER T(p) is too high by 1-3 K in the lower stratosphere but then too low by 1 K near the stratopause and by 2 K in the middle mesosphere. There is little difference between the local thermodynamic equilibrium (LTE) algorithm results below about 70 km from V1.07 and V1.06, but there are substantial improvements/differences for the non-LTE results of V1.07 for the upper mesosphere and lower thermosphere (UMLT) region. In particular, the V1.07 algorithm uses monthly, diurnally averaged CO2 profiles versus latitude from the Whole Atmosphere Community Climate Model. This change has improved the consistency of the character of the tides in its kinetic temperature (T(sub k)). The T(sub k) profiles agree with UMLT values obtained from ground-based measurements of column-averaged OH and O2 emissions and of the Na lidar returns, at least within their mutual uncertainties. SABER T(sub k) values obtained near the mesopause with its daytime algorithm also agree well with the falling sphere climatology at high northern latitudes in summer. It is concluded that the SABER data set can be the basis for improved, diurnal-to-interannual-scale temperatures for the middle atmosphere and especially for its UMLT region.

Remsberg, E. E.↗

An overview of the Halogen Occultation Experiment (HALOE) and preliminary results

The Halogen Occultation Experiment (HALOE) experiment has observed vertical profiles and pressure versus latitude cross sections of temperature HCl, HF, CH4, H2O, NO, NO2, O3, and aerosols over the range from 80 deg S to 80 deg N. An in-orbit precision of better than 0.3 ppbv has been demonstrated for HCl, HF, NO, NO2 and less than 0.6 ppmv for the other channels. Comparisons with correlative measurements at this early stage are encouraging. Nitric oxide has been observed over the range from the upper troposphere to 130-km. Latitudinal cross sections of the long-lived tracers CH4 and HF show clear indications of the effect of the general circulation.

Russell, J. M., III↗

Halogen Occultation Experiment (HALOE) gas cell life test program

The Halogen Occultation Experiment (HALOE) will use gas filter correlation radiometry to measure the atmospheric concentration profiles of HCl, HF, NO, and CH4 from the Upper Atmosphere Research Satellite. The need to contain the gases for the gas filter measurements has resulted in the development of gas cells and the need for a life test program to demonstrate that the gas cells will perform their functions for extended periods (several years) of time. This report describes the tests in the life test program, the test apparatus used, and the analysis techniques developed. The report also presents data obtained during the first 14 months of the test program.

Sullivan, E. M.↗

On-film optical recording of camera lens settings

An apparatus is described for recording a representation of the camera lens aperture and focus setting on the film of a camera, while the photographic image is being recorded. A data lens is provided between the camera lens and film, by means of which the aperture and focus setting may be determined. The determination is made by measuring both the location and the size of a data image provided by the data lens. The data lens apparatus requires no electrical power, is low in weight, and does not result in an increase in the external dimensions of the camera.

Thompson, R. E.↗

Modified camera records lens settings on film

Camera is modified by inserting optical imaging system between lens and film. This system requires no electrical power, is low in weight, and adds nothing to external size of the camera.

Thompson, R. E.↗

Masking of aluminum surface against anodizing

Masking material and a thickening agent preserve limited unanodized areas when aluminum surfaces are anodized with chromic acid. For protection of large areas it combines well with a certain self-adhesive plastic tape.

Crawford, G. B.↗